Elektrostatyka

Ostatnio dodane
2015-06-18
10:12
Analysis of Mathematical Modeling of PV Module with MPPT Algorithm / Chitti Babu, B ; Cermak, T ; Gurjar, S ; Leonowicz, Z ; et al [ENY-ARTICLE-2015-364]
This paper presents the mathematical modeling of photovoltaic (PV) module with the effective comparison of two popular maximum power point tracking (MPPT) techniques; Generally, Maximum Power Point Tracking (MPPT) techniques are used in PV System to extract maximum possible power which in turn depends on solar irradiance and temperature of PV module. [...]
http://zet10.ipee.pwr.wroc.pl/record/457/files/
Rekord szczegółowy - Podobne rekordy
2012-08-03
06:21
Intelligent wireless street lighting system / Leccese, F ; Leonowicz, Z [Digital Object Identifier: 10.1109/EEEIC.2012.6221515] [ENY-ARTICLE-2012-337]
We propose an innovative wireless street lighting system with optimized management and efficiency. [...]
http://zet10.ipee.pwr.wroc.pl/record/424/files/
Rekord szczegółowy - Podobne rekordy
2012-07-20
14:34
Dielectric characterization of electromagnetic composite barrier materials with plasma layers on nonwoven fabrics / Jaroszewski, M [http://dx.doi.org/10.1080/09276440.2012.696942] [ENY-ARTICLE-2012-334]
Composite materials are becoming more widely used in the technique of shielding electromagnetic field. [...]
http://zet10.ipee.pwr.wroc.pl/record/421/files/
Rekord szczegółowy - Podobne rekordy
2012-05-09
14:48
Model of medium voltage metal oxide arrester / Chrzan, K L ; Pohl, Z ; Furgal, J [ENY-ARTICLE-2012-328]
Modelling of MOA is necessary for many reasons and a considerable progress in this field has been made. [...]
http://zet10.ipee.pwr.wroc.pl/record/415/files/
Rekord szczegółowy - Podobne rekordy
2012-04-30
14:52
Influence of moisture and partial discharges on the degradation of high-voltage surge arresters. / Chrzan, K L [ENY-ARTICLE-2012-321]
This paper reports the influence of moisture and internal partial discharges on the degradation of metal oxide varistors in high-voltage surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/408/files/
Rekord szczegółowy - Podobne rekordy
2011-11-08
11:59
EMI Shielding using Composite Materials with Plasma Layers / Ziaja, J ; Jaroszewski, M [ISBN: 978-953-307-304-0] [ENY-BOOK-2011-003]
Electromagnetic compatibility, including the engineering of materials used for shielding from electromagnetic fields, is currently one of the most extensively developing field of applications of composite materials. [...]
http://zet10.ipee.pwr.wroc.pl/record/390/files/
Rekord szczegółowy - Podobne rekordy
2011-10-30
16:42
A development of a solar cell problem. Some further description / Swistacz, B [ENY-ARTICLE-2011-304]
A new concept of a space charge transport between the two electrodes is presented - It was found that generation processes could be described in terms of a voltage parameter V10 and of a field parameter E10 . [...]
http://zet10.ipee.pwr.wroc.pl/record/389/files/
Rekord szczegółowy - Podobne rekordy
2010-06-13
15:44
Reactive Power Compensation / Kepka, J [ENY-THESIS-2010-014]
Over the last few years, the interest in reactive power compensation has been growing, mainly because of the way in which energy supplier charge a customer for reactive power. [...]
http://zet10.ipee.pwr.wroc.pl/record/360/files/
Rekord szczegółowy - Podobne rekordy
2009-12-10
11:38
Inclined plane test, influence of transformer power / Chrzan, K L [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-281]
The inclined plane method is one of a few other tests that prove the material resistance to erosion and tracking caused by surface discharges. [...]
http://zet10.ipee.pwr.wroc.pl/record/349/files/
Rekord szczegółowy - Podobne rekordy
2009-12-10
11:13
Silicone rubber insulators with notched surface / Chrzan, K L [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-276]
A modification of an insulator profile was proposed and the advantage of a new solution was shown. [...]
http://zet10.ipee.pwr.wroc.pl/record/344/files/
Rekord szczegółowy - Podobne rekordy
2009-11-09
13:10
New solution to the problem of bipolar injection in insulator and semiconductor devices / Swistacz, B [ENY-ARTICLE-2009-273]
A problem of the space charge transport with two mobilities is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/341/files/
Rekord szczegółowy - Podobne rekordy
2009-08-28
18:41
Proceedings of the 8. International Conference on Environment and Electrical Engineering, Karpacz, Poland, 10-13. May 2009 / Schwarz, H ; Leonowicz, Z [ENY-PREPRINT-2009-010]
The aim of the Conference is to promote a Forum, where people involved with electrical power systems may exchange their experiences and present solutions found for actual and future problems. [...]
http://zet10.ipee.pwr.wroc.pl/record/326/files/
Rekord szczegółowy - Podobne rekordy
2009-03-15
13:00
Odors Control with Non-Thermal Plasma Reactor / Czapka, T ; Mielcarek, W ; Warycha, J ; Prociow, K ; et al [AZ I07/2008/I-087] [ENY-ARTICLE-2009-255]
Recent public concern about air pollution from production units has prompted more research to develop methods to reduce and control odors. [...]
http://zet10.ipee.pwr.wroc.pl/record/317/files/
Rekord szczegółowy - Podobne rekordy
2009-01-03
11:25
Internal Arcing Test on Polluted High Voltage Surge Arresters / Chrzan, K L ; Kohler, W ; Feser, K [ENY-ARTICLE-2009-234]
A test to prove the performance of extremely non-uniform polluted single unit metal oxide (MO) and gapped arresters (SiCA) is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/293/files/
Rekord szczegółowy - Podobne rekordy
2008-12-20
10:46
Effects of Surface Modification of Polypropylene Foil on Polymer - Oil Interaction / Pospieszna, J ; Tyman, A ; Juchniewicz, J [ENY-ARTICLE-2008-229]
Physico-chemical interactions between the impregnating oil and the polypropylene foil (PP) are of great concern. [...]
http://zet10.ipee.pwr.wroc.pl/record/284/files/
Rekord szczegółowy - Podobne rekordy
2008-12-17
12:10
Steep-front impulse voltage tests of composite insulators / Fleszynski, J ; Sojda, E ; Tyman, A ; Koruba, K [ENY-ARTICLE-2008-228]
It is very important to eliminate improper insulator designs and technological faults. [...]
http://zet10.ipee.pwr.wroc.pl/record/283/files/
Rekord szczegółowy - Podobne rekordy
2008-12-12
11:47
Behaviour of Insulators and Surge Arresters at Glogow Pollution Test Station / Chrzan, K L ; Haddad, A [I07/2005/I-005] [ENY-ARTICLE-2008-222]
The paper reports on the pollution performance of different insulators and surge arresters at Glogow test station from 1981 up to 2004. [...]
http://zet10.ipee.pwr.wroc.pl/record/277/files/
Rekord szczegółowy - Podobne rekordy
2008-11-30
12:44
Application of silicone coatings on porcelain insulators in Poland, a case study / Chrzan, K L [ENY-ARTICLE-2008-219]
Silicone coatings have been used to improve insulating properties of outdoor insulators under polluted conditions for over 30 years. [...]
http://zet10.ipee.pwr.wroc.pl/record/273/files/
Rekord szczegółowy - Podobne rekordy
2008-11-30
12:10
Pollution Performance of 110 kV Metal Oxide Arresters / Chrzan, K L ; Pohl, Z ; Grzybowski, S ; Kohler, W [ENY-ARTICLE-2008-216]
Pollution test results of single unit 110 kV metal oxide surge arresters with porcelain housing according to the solid layer and salt fog methods are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/270/files/
Rekord szczegółowy - Podobne rekordy
2008-11-20
11:18
Behaviour of Zinc Oxide Surge Arresters Under Pollution / Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L [ENY-ARTICLE-2008-214]
This paper presents results of pollution tests with A. [...]
http://zet10.ipee.pwr.wroc.pl/record/268/files/
Rekord szczegółowy - Podobne rekordy