- PSCC

Latest additions:
2009-10-27
10:23
Power Quality in Wind Power Systems / Leonowicz, Z [ENY-ARTICLE-2009-268]
Wind power generation systems influence power quality in a specific way making important the need for detailed and accurate evaluation of disturbances caused by wind generators. [...]
http://zet10.ipee.pwr.wroc.pl/record/336/files/
Detailed record - Similar records
2009-10-27
09:23
Assessment of transient disturbances in HV systems with single-phase autoreclosures / Lobos, T ; Schegner, P ; Sikorski, T [ENY-ARTICLE-2009-265]
This paper proposes some extended method for assessment of transient disturbances in HV system with single-phase autoreclosures. [...]
http://zet10.ipee.pwr.wroc.pl/record/333/files/
Detailed record - Similar records
2009-02-01
10:29
Modern spectral analysis of non-stationary signals in electrical power systems / Leonowicz, Z ; Lobos, T ; Schegner, P [RZ I07/2002/I-048] [ENY-ARTICLE-2009-251]
A novel approach to harmonic and interharmonic analysis, based on the “subspace” methods, is proposed. [...]
http://zet10.ipee.pwr.wroc.pl/record/312/files/
Detailed record - Similar records
2008-10-10
21:18
Analysis of traction system time-varying signals using ESPRIT subspace spectrum estimation method / Leonowicz, Z ; Lobos, T [I07/2006/I-090] [ENY-ARTICLE-2008-190]
Auxiliary static converters in transportation power systems generate not only characteristic harmonics but also non characteristic harmonics and interharmonics. [...]
http://zet10.ipee.pwr.wroc.pl/record/241/files/
Detailed record - Similar records
2008-09-28
07:45
Power quality evaluation using advanced spectrum estimation methods / Leonowicz, Z ; Lobos, T [I07/2006/I-082] [ENY-ARTICLE-2008-174]
The authors show that the use of high-resolution spectrum estimation methods instead of Fourier-based techniques can improve the accuracy of measurement of spectral parameters of distorted waveforms encountered in power systems, in particular the estimation of the power quality indices (such as inter/harmonic groups and subgroups) . [...]
http://zet10.ipee.pwr.wroc.pl/record/223/files/
Detailed record - Similar records
2008-09-27
16:11
New power quality indices / Leonowicz, Z ; [RZ I07/2007/I-024] [ENY-ARTICLE-2008-171]
The author shows that the use of high-resolution spectrum estimation methods instead of Fourier-based techniques can improve the accuracy of measurement of spectral parameters of distorted waveforms encountered in power systems, in particular the estimation of the power quality indices (such as inter/harmonic groups and subgroups). [...]
http://zet10.ipee.pwr.wroc.pl/record/220/files/
Detailed record - Similar records
2008-03-16
21:08
Analysis of distorted waveforms using parametric spectrum estimation methods and robust averaging / Leonowicz, Z [ENY-ARTICLE-2008-074]
After the description of parametric methods (ESPRIT and MUSIC) and selected robust location measures (robust averaging methods), the comparison of the frequency and amplitude estimation error, based on numerical simulation is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/89/files/
Detailed record - Similar records
2008-03-11
23:34
Time-Frequency Analysis of Complex Space-Phasor in Power Electronics / Leonowicz, Z ; Lobos, T ; Sikorski, T [doi:10.1109/TIM.2007.908250] [ENY-ARTICLE-2008-043]
This paper considers applying nonparametric and parametric methods for the calculation of the time–frequency representation of nonstationary signals in power electronics. [...]
http://zet10.ipee.pwr.wroc.pl/record/52/files/
Detailed record - Similar records
2008-03-10
12:16
Adaptacyjne sieci neuronowe w zastosowaniu do identyfikacji stanu układów elektrycznych / Kostyla, P [ENY-THESIS-2008-005]
Celem pracy jest zbadanie możliwości zastosowania sieci neuronowych do estymacji parametrów sygnałów w czasie rzeczywistym, których adaptacyjny algorytm działania oparty jest na nowych kryteriach TLS i RTLS oraz zbadanie możliwości zastosowania wybranych układów sieci neuronowych do identyfikacji stanu pracy niektórych układów elektrycznych. [...]
http://zet10.ipee.pwr.wroc.pl/record/45/files/
Detailed record - Similar records
2008-03-09
14:56
Analysis of Three Phase Signal using Wigner Spectrum / Leonowicz, Z ; Lobos, T [ENY-ARTICLE-2008-032]
New method of observation and diagnosis of inverter-fed induction motor drives is developed and tested. [...]
http://zet10.ipee.pwr.wroc.pl/record/39/files/
Detailed record - Similar records
2008-03-08
11:19
Time-frequency analysis of non-stationary three phase signals / Leonowicz, Z ; Lobos, T [ENY-ARTICLE-2008-028]
New method of observation and diagnosis of inverter-fed induction motor drives is developed and tested. [...]
http://zet10.ipee.pwr.wroc.pl/record/35/files/
Detailed record - Similar records
2008-03-08
10:54
Parametric Spectral Estimation for Power Quality Assessment / Leonowicz, Z ; Lobos, T [1-4244-0813-X/07/$20.00 2007 IEEE] [ENY-ARTICLE-2008-025]
The authors show that the use of highresolution spectrum estimation methods instead of Fourier-based techniques can improve the accuracy of measurement of spectral parameters of distorted waveforms encountered in power systems, in particular the estimation of the power quality indices (such as harmonic and interharmonic groups and subgroups). [...]
http://zet10.ipee.pwr.wroc.pl/record/32/files/
Detailed record - Similar records
2008-03-06
14:18
Evaluation of compensation devices of DC arc furnaces using advanced spectrum estimation methods / Bracale, A ; Carpinelli, G ; Lobos, T ; Leonowicz, Z ; et al [RZ I07/05/I-026] [ENY-ARTICLE-2008-011]
Spectral representation of waveform distor-tions has been of great interest in power systems for many years since the disturbing loads generate a wide spectrum of components which deteriorate the quality of power supply. [...]
http://zet10.ipee.pwr.wroc.pl/record/13/files/
Detailed record - Similar records