Distance Digital Algorithm Immune to Saturation of Current Transformer

Wiszniewski, A (Wroclaw University of Technology, Poland) ; Szafran, J (Wroclaw University of Technology, Poland)

1989-04-01

Abstract: Saturation of current transformers due to slowly decaying primary current D.C. components cause errors in reproduction of the current fundamental harmonic. Most of the relays are more or less sensitive to the errors. If the saturation occures before the given relay operated. the operation may be delayed up to about 2 time constants of the D.C.component. In some, although rare cases, transient CT errors may cause unselective operation of the relay. Whether the current transformer saturates and when it occures depend mainly on the accuracy limit factor and on the residual flux in the transformer core. However bearing in mind the very high expected values of short circuit currents and the long D.C. time constants one may conclude, that the design of CT-s which never saturate would end in bulky and expensive units. Therefore most of the protective CT-s which are in service saturate during severe transients. It is a duty of protection engineers to design the relays in such a way, that the errors caused by the saturation neither cause maloperation, nor bring about excessive delay.

Keyword(s): distance protection ; current transformer
Note: Developments in power system protection. Fourth International Conference, London, 11-13 April 1989. London : IEE, 1989. pp. 196-199


Fulltext : http://zet10.ipee.pwr.wroc.pl/record/260/files/

Cited by: try citation search for ENY-ARTICLE-2008-206; I08/1989/I-044

Rekord stworzony 2008-11-11, ostatnia modyfikacja 2008-11-11

Podobne rekordy


 
Osoby, które oglądały tę stronę, oglądały również:
(916)  Impact of Distributed Generation on Electrical Power Network - Khan, U N - ENY-ARTICLE-2008-142
(916)  Proceedings of the Int. Conference "7th EEEIC International Workshop on Environment and Electrical Engineering" - Schwarz, H et al - ENY-PREPRINT-2008-008
(908)  Adaptacyjne sieci neuronowe w zastosowaniu do identyfikacji stanu układów elektrycznych - Kostyla, P - ENY-THESIS-2008-005
(899)  Measurement of IEC Groups and Subgroups Using Advanced Spectrum Estimation Methods - Bracale, A et al - ENY-ARTICLE-2008-117
(893)  Zadania 1 Podstawy Elektrotechniki Automatyka i Robotyka - Hejke, I et al - ENY-TEACHING-2008-020

 
Oceń ten dokument:
Bądź pierwszy i oceń ten dokument.


Dyskusja nad tym dokumentem:
Rozpocznij dyskusję o tym dokumencie.