Format: HTML | BibTeX | DC | EndNote | NLM | MARC | MARCXML
Published Article / I07/2003/I-035 ENY-ARTICLE-2008-211

Inefficacy of radioactive terminals and early streamer emission terminals

Chrzan, K L (Wroclaw University of Technology, Wroclaw, Poland) ; Hartono, Z A (Lightning Research Pte Ltd, Kuala Lumpur, Malaysia)

2003-07-24

Abstract: The paper reviews about research of radioactive lightning rods carried out 30 years ago and about new measurements of early streamer emission terminals. Lightning damage on over 100 buildings equipped with ESE terminals in Malaysia and on one family house in Poland is reported. The main measure criterion was the breakdown voltage of the air gap consisted of the high voltage electrode (rod or plate) and a grounded radioactive or ESE terminal. These careful measurements show that the air gaps with ESE terminals have the same breakdown voltages as the air gaps with standard rods. Therefore the big protection zone of ESE terminals as claimed by their manufactures seem to be impossible.

Keyword(s): radioactive terminals ; ESE ; lightning stroke ; breakdown voltage
Note: Proceedings of the XIIIth International Symposium on High Voltage Engineering. XIII ISH , Delft, [the] Netherlands, August 25-29, 2003, 4 p.


Fulltext : http://zet10.ipee.pwr.wroc.pl/record/265/files/

Cited by: try citation search for ENY-ARTICLE-2008-211; I07/2003/I-035

Record created 2008-11-20, last modified 2008-11-20

Ähnliche Datensätze


 
Benutzer, die diese Seite angeschaut haben, haben auch angeschaut:
(871)  Proceedings of the Int. Conference "7th EEEIC International Workshop on Environment and Electrical Engineering" - Schwarz, H et al - ENY-PREPRINT-2008-008
(867)  Impact of Distributed Generation on Electrical Power Network - Khan, U N - ENY-ARTICLE-2008-142
(867)  Zadania 1 Podstawy Elektrotechniki Automatyka i Robotyka - Hejke, I et al - ENY-TEACHING-2008-020
(865)  Parametric methods for time-frequency analysis of electric signals - Leonowicz, Z - ENY-BOOK-2008-001
(864)  Adaptacyjne sieci neuronowe w zastosowaniu do identyfikacji stanu układów elektrycznych - Kostyla, P - ENY-THESIS-2008-005

 
Dieses Dokument bewerten:
Als Erster ein Review für dieses Dokument verfassen


Dokument diskutieren:
Diskussion über Dokument starten.