Format: HTML | BibTeX | DC | EndNote | NLM | MARC | MARCXML
Published Article / ENY-ARTICLE-2008-217

Electrical Strength of Air Containing Ozone and Nitric Oxides Produced by Intensive Partial Discharges

Chrzan, K L (Wroclaw University of Technology, Poland) ; Andino, J M (University of Florida, USA)

1999-11-17

Abstract: Internal arcing test results of gapped Sic arresters are presented. During a test in which the arrester is exposed to internal arcing, the positive impulse breakdown voltage increases. Measurements made with a model arrangement indicate that the increase in the electrical strength of gas is higher for positive than for negative impulse polarity. When the internal discharges extinguish, recovery processes occur. Additional phenomena that can cause changes in the electrical strength are discussed.

Keyword(s): SiC arrester ; internal arcing ; arc discharge ; internal discharge
Note: IEEE Transactions on Dielectrics and Electrical Insulation Vol. 8 No. 4, August 2001, pp. 607-611


Fulltext : http://zet10.ipee.pwr.wroc.pl/record/271/files/

Cited by: try citation search for ENY-ARTICLE-2008-217

Rekord stworzony 2008-11-30, ostatnia modyfikacja 2008-12-01

Podobne rekordy


 
Osoby, które oglądały tę stronę, oglądały również:
(970)  Proceedings of the Int. Conference "7th EEEIC International Workshop on Environment and Electrical Engineering" - Schwarz, H et al - ENY-PREPRINT-2008-008
(949)  Adaptacyjne sieci neuronowe w zastosowaniu do identyfikacji stanu układów elektrycznych - Kostyla, P - ENY-THESIS-2008-005
(941)  Impact of Distributed Generation on Electrical Power Network - Khan, U N - ENY-ARTICLE-2008-142
(921)  Evaluation of compensation devices of DC arc furnaces using advanced spectrum estimation methods - Bracale, A et al - ENY-ARTICLE-2008-011
(915)  Parametric methods for time-frequency analysis of electric signals - Leonowicz, Z - ENY-BOOK-2008-001

 
Oceń ten dokument:
Bądź pierwszy i oceń ten dokument.


Dyskusja nad tym dokumentem:
Rozpocznij dyskusję o tym dokumencie.