Abstract: A new method of fault analysis and detection by signal classification in frequency converters is presented. The Wigner-Ville time frequency distribution is used to produce the representation of the signal and the probabilistic neural network as a classifier. The accuracy and robustness of the proposed method is investigated on signals obtained during the different fault mode operations of the industrial frequency converter.
Keyword(s): Fault diagnosis ; Neural Networks applications ; Power system faults ; Pulse width modulated power converters ; Time – frequency analysis ; Wigner distributions