Analysis of Distorted Waveforms in Power Converter Systems

Rezmer, J (Wroclaw University of Technology) ; Leonowicz, Z (Wroclaw University of Technology)

2010-11-01

Abstract: The paper presents a method of determining the frequency developed and based on the Prony model. The method was derived for those cases in which the process contains two dominant harmonics and noise. Additionally, in order to improve the accuracy of the method, median filtering was applied. The presented methods can be useful for practical applications in power systems, like the control systems of frequency converters.

Keyword(s): Prony model ; frequency estimation ; waveform distortion ; median filter ; parameter estimation
Note: preprint


Fulltext : http://zet10.ipee.pwr.wroc.pl/record/369/files/

Cited by: try citation search for ENY-PREPRINT-2010-011

Record created 2010-11-08, last modified 2011-10-31

Ähnliche Datensätze


 
Benutzer, die diese Seite angeschaut haben, haben auch angeschaut:
(800)  Proceedings of the Int. Conference "7th EEEIC International Workshop on Environment and Electrical Engineering" - Schwarz, H et al - ENY-PREPRINT-2008-008
(780)  Zadania 1 Podstawy Elektrotechniki Automatyka i Robotyka - Hejke, I et al - ENY-TEACHING-2008-020
(779)  Proceedings of the 8. International Conference on Environment and Electrical Engineering, Karpacz, Poland, 10-13. May 2009 - Schwarz, H et al - ENY-PREPRINT-2009-010
(762)  Adaptacyjne sieci neuronowe w zastosowaniu do identyfikacji stanu układów elektrycznych - Kostyla, P - ENY-THESIS-2008-005
(762)  Impact of Distributed Generation on Electrical Power Network - Khan, U N - ENY-ARTICLE-2008-142

 
Dieses Dokument bewerten:
Als Erster ein Review für dieses Dokument verfassen


Dokument diskutieren:
Diskussion über Dokument starten.