Format: HTML | BibTeX | DC | EndNote | NLM | MARC | MARCXML
Published Article / I07/1988/P-343 ENY-ARTICLE-2008-070

The Effect of Low Temperature on the Role Played by Electrodes in Vacuum Breakdown

Mazurek, B (Wroclaw University of Technology, Poland)

1989-02-19

Abstract: Electrical breakdown requires the creation of plasma in inter electrode space. The electrodes are the source of plasma, but the more important dense plasma is created on the anode. In a system with an insulating spacer, the insulator material is the source of plasma. The cooling of the anode needs more energy for plasma creation. Similarly, cooling of the insulator part where the plasma is created increases the electrical strength.

Note: IEEE Transactions on Electrical Insulation. 1989 vol. 24, nr 6, s. 933-936


Fulltext : http://zet10.ipee.pwr.wroc.pl/record/79/files/

Cited by: try citation search for ENY-ARTICLE-2008-070; I07/1988/P-343

Rekord stworzony 2008-03-14, ostatnia modyfikacja 2008-03-14

Podobne rekordy


 
Osoby, które oglądały tę stronę, oglądały również:
(893)  Impact of Distributed Generation on Electrical Power Network - Khan, U N - ENY-ARTICLE-2008-142
(883)  Proceedings of the Int. Conference "7th EEEIC International Workshop on Environment and Electrical Engineering" - Schwarz, H et al - ENY-PREPRINT-2008-008
(879)  Adaptacyjne sieci neuronowe w zastosowaniu do identyfikacji stanu układów elektrycznych - Kostyla, P - ENY-THESIS-2008-005
(878)  Zadania 1 Podstawy Elektrotechniki Automatyka i Robotyka - Hejke, I et al - ENY-TEACHING-2008-020
(876)  Elektrotechnika Teoretyczna. Analiza układów nieliniowych - Luczycki, A et al - ENY-BOOK-2008-002

 
Oceń ten dokument:
Bądź pierwszy i oceń ten dokument.


Dyskusja nad tym dokumentem:
Rozpocznij dyskusję o tym dokumencie.