Format: HTML | BibTeX | DC | EndNote | NLM | MARC | MARCXML
Published Article / I07/1995/I-220 ENY-ARTICLE-2008-077

Inactivation of Yersinia enterocolitica Gram-negative bacteria using high voltage technique

Lubicki, P (University of Waterloo, Canada) ; Cross, J D (University of Waterloo, Canada) ; Jayaram, S (University of Waterloo, Canada) ; Mazurek, B (Wroclaw University of Technology, Poland) ; Staroniewicz, Z (Academy of Agriculture, Wroclaw, Poland)

1995-01-01

Abstract: High voltage pulses of peak voltages U=5-75 kV and rise times tp=500-1300 ns were applied with repetition frequency f=lHz in order to cause the irreversible electroporation of Gram negative bacteria Yersinia enterocolitica. The bacteria were suspended in NaCl solution of pH=7.2 and conductivity y ~0.8-1.3 S/m. The suspension was placed in glass tube immersed in the cylindrical electrode system gap filled with distilled water. Such an electrode system will protect the bacteria suspension from the chemical processes at the electrode-liquid interface due to conduction and pre-breakdown phenomena. The current chopping electrode system was connected in parallel to the sample in order to avoid heat generation from direct discharge of the pulse through the suspension. The dependence of the survival ratio s=N/No (the number of bacteria per cm3 after pulse treatment, N, divided by the number of bacteria per cm3 before treatment, NJ of Y. enterocolitica on peak voltage of the pulse, number of pulses applied and on various rise times of pulses have been measured. The reduction by 6 orders of magnitude of Y. enterocolitica living cells per cm3 was achieved. The results show that considerable inactivation of microbes can be achieved by the application of short (tp 4000 ns) high voltage pulses for bacteria suspension without directly exposing the bacteria suspension to the electrodes. It is therefore possible to use the electrode system proposed as a means for sterilization of liquid foods.

Note: 1995 IEEE Industry Applications Conference. Thirtieth IAS Annual Meeting, Orlando, Florida, October 8-12, 1995. Vol. 2 Piscataway, NJ : IEEE, 1995. pp. 1338-1344


Fulltext : http://zet10.ipee.pwr.wroc.pl/record/95/files/

Cited by: try citation search for ENY-ARTICLE-2008-077; I07/1995/I-220

Record created 2008-03-20, last modified 2008-09-19

Similar records


 
People who viewed this page also viewed:
(885)  Impact of Distributed Generation on Electrical Power Network - Khan, U N - ENY-ARTICLE-2008-142
(875)  Adaptacyjne sieci neuronowe w zastosowaniu do identyfikacji stanu układów elektrycznych - Kostyla, P - ENY-THESIS-2008-005
(862)  Zadania 1 Podstawy Elektrotechniki Automatyka i Robotyka - Hejke, I et al - ENY-TEACHING-2008-020
(858)  Elektrotechnika Teoretyczna. Analiza układów nieliniowych - Luczycki, A et al - ENY-BOOK-2008-002
(850)  Measurement of IEC Groups and Subgroups Using Advanced Spectrum Estimation Methods - Bracale, A et al - ENY-ARTICLE-2008-117

 
Rate this document:
Be the first to review this document.


Discuss this document:
Start a discussion about any aspect of this document.