Elektrotechnik TU Wroclaw

Elektrotechnik TU Wroclaw 192 Datensätze gefunden  Anfangvorherige12 - 21nächsteEnde  gehen zum Datensatz: Die Suche hat 0.02 Sekunden gedauert. 
12. Comparison between DFT, Adaptive Window DFT and EDFT for Power Quality Frequency Spectrum Analysis / Grossoni, M ; Giarnetti, S ; Leccese, F ; Leonowicz, Z [DOI: 10.13140/2.1.3741.1849] [ENY-ARTICLE-2010-292]
Spectral leakage and picket-fence effects associated with the system fundamental frequency variation and improperly selected sampling time window prevents a direct application of the DFT algorithm with a constant sampling rate. [...]
http://zet10.ipee.pwr.wroc.pl/record/364/files/
Details vom Eintrag - Ähnliche Datensätze
13. Wavelets and Hilbert Transform for detection of short disturbances in electrical power networks / Caciotta, M ; Giarnetti, S ; Leccese, F ; Leonowicz, Z [ENY-ARTICLE-2010-287]
In electrical energy power network, disturbances can cause problems in electronic devices therefore their monitoring is fundamental to properly design the protection and compensation devices. [...]
http://zet10.ipee.pwr.wroc.pl/record/357/files/
Details vom Eintrag - Ähnliche Datensätze
14. Inclined plane test, influence of transformer power / Chrzan, K L [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-281]
The inclined plane method is one of a few other tests that prove the material resistance to erosion and tracking caused by surface discharges. [...]
http://zet10.ipee.pwr.wroc.pl/record/349/files/
Details vom Eintrag - Ähnliche Datensätze
15. Hygroscopic properties of natural pollutants on silicone rubber surfaces / Chrzan, K L ; Greyling, C [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-280]
The aim of this research is to determine whether hydrophilic and hygroscopic particulate pollutants on glass and silicone insulator surfaces maintain their electrical and water absorption properties, once low molecular weight siloxanes have migrated through the pollution layer. [...]
http://zet10.ipee.pwr.wroc.pl/record/348/files/
Details vom Eintrag - Ähnliche Datensätze
16. Artificial rain test of outdoor long rod insulators / Chrzan, K L ; Streubel, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-279]
Due to the decrease of industrial contamination emission nearly the whole territory of Poland belongs to the pollution class light. [...]
http://zet10.ipee.pwr.wroc.pl/record/347/files/
Details vom Eintrag - Ähnliche Datensätze
17. Effect of impulse polarity on the flashover voltage of polluted cap and pin insulators / Chrzan, K L ; Schwarz, H ; Haeusler, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-278]
The lightning impulse flashover voltage on clean and polluted cap and pin insulators under high humidity conditions were measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/346/files/
Details vom Eintrag - Ähnliche Datensätze
18. Time-varying signal parameters for assessment of disturbances in wind energy systems / Lobos, T ; Schegner, P ; Sikorski, T [ENY-ARTICLE-2009-270]
This paper proposes some extended method for assessment of transient disturbances in wind energy systems. [...]
http://zet10.ipee.pwr.wroc.pl/record/338/files/
Details vom Eintrag - Ähnliche Datensätze
19. Detection of Short Transients and Interruptions using the Hilbert Transform / Caciotta, M ; Giarnetti, S ; Leccese, F ; Leonowicz, Z [ENY-ARTICLE-2009-269]
In electrical energy power networks, disturbances can cause problems in electronic devices so their monitoring is fundamental in Power Quality. [...]
http://zet10.ipee.pwr.wroc.pl/record/337/files/
Details vom Eintrag - Ähnliche Datensätze
20. Power Quality in Wind Power Systems / Leonowicz, Z [ENY-ARTICLE-2009-268]
Wind power generation systems influence power quality in a specific way making important the need for detailed and accurate evaluation of disturbances caused by wind generators. [...]
http://zet10.ipee.pwr.wroc.pl/record/336/files/
Details vom Eintrag - Ähnliche Datensätze
21. Nonlinear regression applied for power quality disturbances characterization in grids with wind generators / Janik, P ; Lobos, T ; Rezmer, J ; Waclawek, Z [I07/2009/I-035] [ENY-ARTICLE-2009-267]
The impact of wind generation on the electrical system should be assessed to figure out potential hazards to system operation and deterioration of power quality indices. [...]
http://zet10.ipee.pwr.wroc.pl/record/335/files/
Details vom Eintrag - Ähnliche Datensätze

Elektrotechnik TU Wroclaw : 192 Datensätze gefunden   Anfangvorherige12 - 21nächsteEnde  gehen zum Datensatz:
Haben Sie nicht gefunden was Sie suchten? Versuchen Sie Ihre Suche auf anderen Servern:
poland in Google Books
poland in Google Scholar
poland in Google Web
poland in INSPEC