Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 305 rekordów  początekpoprzedni136 - 145następnykoniec  skocz do rekordu: Szukanie trwało 0.02 sekund. 
136. Distance Digital Algorithm Immune to Saturation of Current Transformer / Wiszniewski, A ; Szafran, J [I08/1989/I-044] [ENY-ARTICLE-2008-206]
Saturation of current transformers due to slowly decaying primary current D. [...]
http://zet10.ipee.pwr.wroc.pl/record/260/files/
Rekord szczegółowy - Podobne rekordy
137. Calculation of Current Transformer Transient Errors / Wiszniewski, A [ENY-ARTICLE-2008-205]
Transient saturation of current transformers may cause maloperation of protective devices. [...]
http://zet10.ipee.pwr.wroc.pl/record/259/files/
Rekord szczegółowy - Podobne rekordy
138. Transverse Interference Voltages on Secondary Protection Wiring at Substations / Wiszniewski, A ; Marczonek, S [ENY-ARTICLE-2008-204]
This paper presents simple equivalent circuits which enables calculation of expected values of transverse interference voltages on various secondary circuits at Substations. [...]
http://zet10.ipee.pwr.wroc.pl/record/258/files/
Rekord szczegółowy - Podobne rekordy
139. CT saturation correction based on the estimated CT saturation time constant / Rebizant, W ; Wiszniewski, A ; Schiel, L [I08/2008/I-021] [ENY-ARTICLE-2008-203]
A new method for CT saturation correction is presented that is based on an on-line estimation of the CT magnetizing inductance. [...]
http://zet10.ipee.pwr.wroc.pl/record/257/files/
Rekord szczegółowy - Podobne rekordy
140. Correction of Current Transformer Transient Performance / Wiszniewski, A ; Rebizant, W ; Schiel, L [ENY-ARTICLE-2008-202]
If a current transformer (CT) saturates while transforming the heavy primary current, in each period, there are sections when the magnetic core is unsaturated and transformation is correct, and when it is saturated, it causes enormous errors. [...]
http://zet10.ipee.pwr.wroc.pl/record/256/files/
Rekord szczegółowy - Podobne rekordy
141. New Criteria of Voltage Stability Margin for the Purpose of Load Shedding / Wiszniewski, A [ENY-ARTICLE-2008-201]
Voltage instability is a phenomenon which often contributes to the development of power system disturbances. [...]
http://zet10.ipee.pwr.wroc.pl/record/255/files/
Rekord szczegółowy - Podobne rekordy
142. Thermally stimulated current in high resistivity Cd0.85Mn0.15Te doped with Indium. / Wrobel, J M ; Gubanski, A ; Placzek-Popko, E ; Rezmer, J ; et al [I09/2008/I-044] [ENY-ARTICLE-2008-200]
Charge carrier traps in Cd(0,85)Mn(0,15)Te doped with indium were studied using thermally stimulated current measurements. [...]
http://zet10.ipee.pwr.wroc.pl/record/254/files/
Rekord szczegółowy - Podobne rekordy
143. Ultrasaturation Phenomenon in Power Transformers—Myths and Reality / Wiszniewski, A ; Rebizant, W ; Bejmert, D ; Schiel, L [ENY-ARTICLE-2008-199]
In this paper, the ultrasaturation phenomenon of power transformers during their energization is studied. [...]
http://zet10.ipee.pwr.wroc.pl/record/253/files/
Rekord szczegółowy - Podobne rekordy
144. How to Reduce Errors of Distance Fault Locating Algorithms / Wiszniewski, A [ENY-ARTICLE-2008-198]
Distance fault locating digital algorithms are often based on the processing of fundamental components which are contained in the currents and Voltages. [...]
http://zet10.ipee.pwr.wroc.pl/record/252/files/
Rekord szczegółowy - Podobne rekordy
145. A multi-criteria differential transformer relay based on fuzzy logic / Wiszniewski, A ; Kasztenny, B [ENY-ARTICLE-2008-197]
This paper presents a digital relay scheme for the primary protection of power transformers. [...]
http://zet10.ipee.pwr.wroc.pl/record/251/files/
Rekord szczegółowy - Podobne rekordy

Repozytorium W. Elektrycznego Politechniki Wrocławskiej : Znaleziono 305 rekordów   początekpoprzedni136 - 145następnykoniec  skocz do rekordu:
Jeżeli nie znaleziono tego czego szukasz, spróbuj szukać na innych serwerach:
university w Google Books
university w Google Scholar
university w Google Web
university w INSPEC