Elektrotechnik TU Wroclaw


No exact match found for Stuttgart+University, using Stuttgart University instead...
Elektrotechnik TU Wroclaw 13 Datensätze gefunden  1 - 10nächste  gehen zum Datensatz: Die Suche hat 0.03 Sekunden gedauert. 
1. Pollution flashover of single unit metal oxide arresters / Chrzan, K L ; Koehler, W. [ENY-ARTICLE-2013-342]
Flashover voltage of uniform and non-uniform polluted metal oxide arresters and their porcelain housings without internal parts was measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/429/files/
Details vom Eintrag - Ähnliche Datensätze
2. Impulse flashover of strings containing standard and semi-conducting disc insulators / Chrzan, K L ; Elsaesser, O [ENY-ARTICLE-2012-324]
Insulators with semi-conducting glazes (SCG insulators) are used mainly in heavily polluted areas. [...]
http://zet10.ipee.pwr.wroc.pl/record/411/files/
Details vom Eintrag - Ähnliche Datensätze
3. Thermische Eigenshaften von Fremdschichten / Chrzan, K L ; Koehler, W [ENY-ARTICLE-2012-317]
In the paper the conductive behavior of saturated and unsaturated electrolytic solutions as a function of temperature is discussed. [...]
http://zet10.ipee.pwr.wroc.pl/record/404/files/
Details vom Eintrag - Ähnliche Datensätze
4. Internal Arcing Test on Polluted High Voltage Surge Arresters / Chrzan, K L ; Kohler, W ; Feser, K [ENY-ARTICLE-2009-234]
A test to prove the performance of extremely non-uniform polluted single unit metal oxide (MO) and gapped arresters (SiCA) is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/293/files/
Details vom Eintrag - Ähnliche Datensätze
5. Pollution Performance of 110 kV Metal Oxide Arresters / Chrzan, K L ; Pohl, Z ; Grzybowski, S ; Kohler, W [ENY-ARTICLE-2008-216]
Pollution test results of single unit 110 kV metal oxide surge arresters with porcelain housing according to the solid layer and salt fog methods are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/270/files/
Details vom Eintrag - Ähnliche Datensätze
6. Behaviour of Zinc Oxide Surge Arresters Under Pollution / Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L [ENY-ARTICLE-2008-214]
This paper presents results of pollution tests with A. [...]
http://zet10.ipee.pwr.wroc.pl/record/268/files/
Details vom Eintrag - Ähnliche Datensätze
7. Behaviour of zinc oxide surge arresters under pollution / Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L [I07/1990/I-114] [ENY-ARTICLE-2008-213]
This paper presents results of pollution tests with AC voltages which were carried out with a multi-unit zinc oxide arrester. [...]
http://zet10.ipee.pwr.wroc.pl/record/267/files/
Details vom Eintrag - Ähnliche Datensätze
8. Diagnostics of high voltage metal oxide arresters procedure errors / Chrzan, K L ; Koehler, W [I07/2000/I-059] [ENY-ARTICLE-2008-193]
A technique has been described which can determine ac resistive current directly or by obtaining the watt loss of the test specimen and dividing by the true rms (trms) value or the applied voltage. [...]
http://zet10.ipee.pwr.wroc.pl/record/247/files/
Details vom Eintrag - Ähnliche Datensätze
9. Fuzzy Logic Application to Out-Of-Step Protection of Generators / Rebizant, W ; Feser, K [I08/2001/I-110] [ENY-ARTICLE-2008-163]
Efficient protection scheme against out-of-step (OS) conditions based on fuzzy logic (FL) technique is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/210/files/
Details vom Eintrag - Ähnliche Datensätze
10. Out-of-Step Protection with AI Methods / Rebizant, W ; Feser, K [I08/2001/I-033] [ENY-ARTICLE-2008-161]
In the paper the results of investigations on the application of Artificial Intelligence (AI) methods to the out-ofstep (OS) protection of synchronous machines are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/208/files/
Details vom Eintrag - Ähnliche Datensätze

Elektrotechnik TU Wroclaw : 13 Datensätze gefunden   1 - 10nächste  gehen zum Datensatz:
Haben Sie nicht gefunden was Sie suchten? Versuchen Sie Ihre Suche auf anderen Servern:
Stuttgart+University in Google Books
Stuttgart+University in Google Scholar
Stuttgart+University in Google Web
Stuttgart+University in INSPEC