Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 430 rekordów  początekpoprzedni231 - 240następnykoniec  skocz do rekordu: Szukanie trwało 0.00 sekund. 
231. Adaptive Measurement of Power System Currents, Voltages and Impedances in Off-nominal Frequency Conditions / Szafran, J ; Rebizant, W ; Michalik, M [I08/1999/I-047] [ENY-ARTICLE-2008-162]
In the paper the problem of basic power system electric quantities (current, voltage magnitudes, power and impedance) measurement in off-nominal frequency conditions is considered under assumption thal the quantities are calculated from orthogonal components of input current and voltage phasors which are obtained by use of the nonrecursive digital filters. [...]
http://zet10.ipee.pwr.wroc.pl/record/209/files/
Rekord szczegółowy - Podobne rekordy
232. Out-of-Step Protection with AI Methods / Rebizant, W ; Feser, K [I08/2001/I-033] [ENY-ARTICLE-2008-161]
In the paper the results of investigations on the application of Artificial Intelligence (AI) methods to the out-ofstep (OS) protection of synchronous machines are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/208/files/
Rekord szczegółowy - Podobne rekordy
233. Simulative Analysis of a New Type Wide Range Estimator of Protection Criterion Values / Szafran, J ; Rebizant, W ; Michalik, M [I08/1998/I-119] [ENY-ARTICLE-2008-160]
In the paper a new adaptive estimator of protection criterion values insensitive to wide range power system frequency changes is proposed and analysed. [...]
http://zet10.ipee.pwr.wroc.pl/record/207/files/
Rekord szczegółowy - Podobne rekordy
234. Efficient Frequency-Adaptive Amplitude Tracking Algorithms for Protection Purposes / Rebizant, W ; Rusek, B [I08/2003/I-091] [ENY-ARTICLE-2008-159]
The new, fast and adaptive algorithms for measurement of signal amplitude for protection and control purposes are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/206/files/
Rekord szczegółowy - Podobne rekordy
235. Asynchronous Generator Behavior After a Sudden Load Rejection / Rebizant, W ; Terzija, V [I08/2003/I-092] [ENY-ARTICLE-2008-158]
In the paper load rejection test, performed at a hydro power plant in Sweden, equipped with asynchronous generators, is described and analysed from the electromechanical transient processes and signal distortions points of view. [...]
http://zet10.ipee.pwr.wroc.pl/record/205/files/
Rekord szczegółowy - Podobne rekordy
236. Accurate Location of Faults on Three-Terminal Line with Use of Three-End Unsynchronised Measurements / Izykowski, J ; Rosolowski, E ; Molag, R ; Balcerek, P ; et al [ENY-ARTICLE-2008-157]
This paper presents a new fault location algorithm for three-terminal line utilising unsynchronised measurements of three-end currents and voltages. [...]
http://zet10.ipee.pwr.wroc.pl/record/204/files/
Rekord szczegółowy - Podobne rekordy
237. A New Fault Location Algorithm for Use with Current Differential Protective Relays of Two-Terminal Line / Izykowski, J ; Rosolowski, E ; Saha, M [ENY-ARTICLE-2008-156]
A new fault location algorithm utilising synchronised measurements of two-end currents and one-end voltage is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/203/files/
Rekord szczegółowy - Podobne rekordy
238. Wavelets and Prony Method for Disturbance Detection in Wind Farms / Lobos, T ; Rezmer, J ; Janik, P ; Amaris, H ; et al [ENY-ARTICLE-2008-155]
Wind generator impact on power quality is crucial for power system operation. [...]
http://zet10.ipee.pwr.wroc.pl/record/202/files/
Rekord szczegółowy - Podobne rekordy
239. Advanced Signal Processing Methods for Evaluation of Harmonic Distortion Caused by DFIG Wind Generator / Janik, P ; Leonowicz, Z ; Rezmer, J ; Schostan, S ; et al [ENY-ARTICLE-2008-154]
Intensified growth of wind power generation emphasizes the need for detailed evaluation of disturbances caused by wind generators. [...]
http://zet10.ipee.pwr.wroc.pl/record/201/files/
Rekord szczegółowy - Podobne rekordy
240. Rola zabezpieczeń upływowych w kopalnianych sieciach IT / Gierczuk, S [ENY-THESIS-2008-008]
Celem niniejszej pracy jest dokonanie analizy, jak ważną rolę pełnią zabezpieczenia upływowe w kopalnianych sieciach IT oraz opracowanie i wykonanie dydaktycznego stanowiska laboratoryjnego do przeprowadzania badań wybranego blokującego zabezpieczenia upływowego. [...]
http://zet10.ipee.pwr.wroc.pl/record/200/files/
Rekord szczegółowy - Podobne rekordy

Repozytorium W. Elektrycznego Politechniki Wrocławskiej : Znaleziono 430 rekordów   początekpoprzedni231 - 240następnykoniec  skocz do rekordu: