Articles

Articles 348 records found  beginprevious119 - 128nextend  jump to record: Search took 0.01 seconds. 
119. Internal Arcing Test on Polluted High Voltage Surge Arresters / Chrzan, K L ; Kohler, W ; Feser, K [ENY-ARTICLE-2009-234]
A test to prove the performance of extremely non-uniform polluted single unit metal oxide (MO) and gapped arresters (SiCA) is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/293/files/
Detailed record - Similar records
120. Influence of High Voltage Insulator on Pollution Flashover Voltage / Wankowicz, J G ; Pohl, Z [ENY-ARTICLE-2009-233]
Results of pollution flashover voltage measurements and optical observation obtained for high voltage insulators placed in the vertical and the horizontal positions are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/292/files/
Detailed record - Similar records
121. Insulators Glaze Modified by Plasma Processes / Tyman, A ; Pospieszna, J ; Juchniewicz, J [ENY-ARTICLE-2009-232]
Surface properties of electrical insulators are responsible for their behaviour, especially during heavy rains in contaminated areas. [...]
http://zet10.ipee.pwr.wroc.pl/record/291/files/
Detailed record - Similar records
122. Special Insulator for Installation of Optical Phase Conductor on 15 kV Line / Argasinska, H ; Fleszynski, J ; Sojda, E ; Tyman, A [ENY-ARTICLE-2008-231]
Thanks to the recent improvements in the technology of glass fibres and the development of digital data transmission techniques, optical fibres have made their way into power distribution and industry. [...]
http://zet10.ipee.pwr.wroc.pl/record/286/files/
Detailed record - Similar records
123. Studies of Epoxy Spacers Subjected to Internal and External Partial Discharge and SF6 Byproducts / Braun, J M ; Chu, F Y ; Tyman, A [ENY-ARTICLE-2008-230]
Ihe reliability of gas insulated switchgear (GIS) has generally been good. [...]
http://zet10.ipee.pwr.wroc.pl/record/285/files/
Detailed record - Similar records
124. Effects of Surface Modification of Polypropylene Foil on Polymer - Oil Interaction / Pospieszna, J ; Tyman, A ; Juchniewicz, J [ENY-ARTICLE-2008-229]
Physico-chemical interactions between the impregnating oil and the polypropylene foil (PP) are of great concern. [...]
http://zet10.ipee.pwr.wroc.pl/record/284/files/
Detailed record - Similar records
125. Steep-front impulse voltage tests of composite insulators / Fleszynski, J ; Sojda, E ; Tyman, A ; Koruba, K [ENY-ARTICLE-2008-228]
It is very important to eliminate improper insulator designs and technological faults. [...]
http://zet10.ipee.pwr.wroc.pl/record/283/files/
Detailed record - Similar records
126. Behaviour of modified insulator surface material under electric stress / Fleszynski, J ; Tyman, A [ENY-ARTICLE-2008-227]
Performance of electrical insulators is strongly dependent on their surface properties. [...]
http://zet10.ipee.pwr.wroc.pl/record/282/files/
Detailed record - Similar records
127. The Effect of the Number of Spacer Insulators on the Breakdown Voltage of Vacuum Insulation / Juchniewicz, J ; Mazurek, B ; Tyman, A [ENY-ARTICLE-2008-226]
It was shown that when extended high voltage vacuum insulation is being considered, the effect of the he number of spacer insulators on the breakdown voltage of the system has to be taken into account. [...]
http://zet10.ipee.pwr.wroc.pl/record/281/files/
Detailed record - Similar records
128. Voltage Endurance Test of Vacuum Insulation for Cryocables / Juchniewicz, J ; Tyman, A [ENY-ARTICLE-2008-225]
Vacuum insulation with cylindrical ceramic spacer insulators has been studied with respect to changes of its ac flashover voltage with time. [...]
http://zet10.ipee.pwr.wroc.pl/record/280/files/
Detailed record - Similar records

Articles : 348 records found   beginprevious119 - 128nextend  jump to record: