31. Composites Made of Polypropylene Nonwoven Fabric with Plasmas Layers / Jaroszewski, M ; Pospieszna, J ; Ziaja, J ; Ozimek, M [ENY-ARTICLE-2012-330]
Engineering of materials used for shielding from electromagnetic fields is currently one of the most extensively developing field of applications of composite materials (Bula et al. [...]
http://zet10.ipee.pwr.wroc.pl/record/417/files/
Details vom Eintrag - Ähnliche Datensätze
32. LONG-TERM STUDY OF CHANGES OF PHYSICO-CHEMICAL PARAMETERS OF TRANSFORMER OILS / Jaroszewski, M ; Pietruszewicz, M [ENY-ARTICLE-2012-329]
The average age of transformers in service is increasing and approaching the end of design life. [...]
http://zet10.ipee.pwr.wroc.pl/record/416/files/
Details vom Eintrag - Ähnliche Datensätze
33. Model of medium voltage metal oxide arrester / Chrzan, K L ; Pohl, Z ; Furgal, J [ENY-ARTICLE-2012-328]
Modelling of MOA is necessary for many reasons and a considerable progress in this field has been made. [...]
http://zet10.ipee.pwr.wroc.pl/record/415/files/
Details vom Eintrag - Ähnliche Datensätze
34. Internal partial discharges test for metal oxide surge arresters / Chrzan, K L [ENY-ARTICLE-2012-327]
Proposals for testing of surge arresters performance under internal partial discharge stress by Sakshaug, Chrzan and Korycki have been presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/414/files/
Details vom Eintrag - Ähnliche Datensätze
35. Application of lightning location systems for fault detection on transmission and distribution lines / Chrzan, K L ; Bodzak, P ; Gajda, W [ENY-ARTICLE-2012-326]
The lightning location systems were installed in many countries during last twenty years. [...]
http://zet10.ipee.pwr.wroc.pl/record/413/files/
Details vom Eintrag - Ähnliche Datensätze
36. Influence of pollution layer thickness on flashover voltage of HV insulators / Wankowicz, J ; Chrzan, K L ; Pohl, Z [ENY-ARTICLE-2012-325]
The pollution characteristics (the relationships of flashover voltage and SDD or maximum current Imax ) for insulators contaminated with uniform or nonuniform coatings with different thickness h are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/412/files/
Details vom Eintrag - Ähnliche Datensätze
37. Impulse flashover of strings containing standard and semi-conducting disc insulators / Chrzan, K L ; Elsaesser, O [ENY-ARTICLE-2012-324]
Insulators with semi-conducting glazes (SCG insulators) are used mainly in heavily polluted areas. [...]
http://zet10.ipee.pwr.wroc.pl/record/411/files/
Details vom Eintrag - Ähnliche Datensätze
38. Artificial aging of polymer insulation surface in a clean fog chamber and its evaluation / Pilling, J ; Chran, K ; Hofmann, J ; Baersch, R [ENY-ARTICLE-2012-323]
It is reported about electrical performance of room temperature vulcanizing (RTV) silicone rubber insulator coatings and epoxy insulators under accelerating aging in a clean chamber. [...]
http://zet10.ipee.pwr.wroc.pl/record/410/files/
Details vom Eintrag - Ähnliche Datensätze
39. The role of gases in the pollution problem of outdoor insulators / Chrzan, K L [ENY-ARTICLE-2012-322]
Experiments on the absorption of SO2 and CO2 by destilled water and by some electrolytic solutions have been conducted in laboratory and on the site. [...]
http://zet10.ipee.pwr.wroc.pl/record/409/files/
Details vom Eintrag - Ähnliche Datensätze
40. Influence of moisture and partial discharges on the degradation of high-voltage surge arresters. / Chrzan, K L [ENY-ARTICLE-2012-321]
This paper reports the influence of moisture and internal partial discharges on the degradation of metal oxide varistors in high-voltage surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/408/files/