Articles

Articles 348 records found  beginprevious159 - 168nextend  jump to record: Search took 0.01 seconds. 
159. Voltage Disturbances Standard EN 50160 - Voltage Characteristics in Public Distribution Systems / Markiewicz, H ; Klajn, A [ENY-ARTICLE-2008-194]
Electrical energy is a product and, like any other product, should satisfy the proper quality requirements. [...]
http://zet10.ipee.pwr.wroc.pl/record/248/files/
Detailed record - Similar records
160. Diagnostics of high voltage metal oxide arresters procedure errors / Chrzan, K L ; Koehler, W [I07/2000/I-059] [ENY-ARTICLE-2008-193]
A technique has been described which can determine ac resistive current directly or by obtaining the watt loss of the test specimen and dividing by the true rms (trms) value or the applied voltage. [...]
http://zet10.ipee.pwr.wroc.pl/record/247/files/
Detailed record - Similar records
161. Impact of environmental conditions in West Europe, Poland and Algeria on outdoor insulators performance and selection / Chrzan, K L ; Abdi, S E [I07/2007/I-045] [ENY-ARTICLE-2008-192]
This paper presents the data of environmental conditions in France, Germany, Poland and Algeria. [...]
http://zet10.ipee.pwr.wroc.pl/record/246/files/
Detailed record - Similar records
162. Time-frequency analysis of non-stationary phenomena in electrical engineering / Bracale, A ; Carpinelli, G ; Wozniak, K ; Sikorski, T ; et al [I07/2006/I-037] [ENY-ARTICLE-2008-191]
This paper serves the idea of applying joint time-frequency representations in electrical engineering. [...]
http://zet10.ipee.pwr.wroc.pl/record/242/files/
Detailed record - Similar records
163. Analysis of traction system time-varying signals using ESPRIT subspace spectrum estimation method / Leonowicz, Z ; Lobos, T [I07/2006/I-090] [ENY-ARTICLE-2008-190]
Auxiliary static converters in transportation power systems generate not only characteristic harmonics but also non characteristic harmonics and interharmonics. [...]
http://zet10.ipee.pwr.wroc.pl/record/241/files/
Detailed record - Similar records
164. A new approach to anti-fog design for polymeric insulators / Haddad, A ; Chrzan, K L ; Griffiths, H ; Waters, R T [I07/2007/I-046] [ENY-ARTICLE-2008-189]
First results are reported of tests with a patterned texture, silicone rubber surface. [...]
http://zet10.ipee.pwr.wroc.pl/record/240/files/
Detailed record - Similar records
165. Performance of polymer concrete insulators under light pollution / Chrzan, K L ; Skoczylas, M [I07/2007/I-041] [ENY-ARTICLE-2008-188]
Abstract: This paper deals with polymer concrete, a highly filled composite material as a low cost alternative to porcelain outdoor insulators. [...]
http://zet10.ipee.pwr.wroc.pl/record/239/files/
Detailed record - Similar records
166. Termovision diagnostics of metal oxide surge arresters / Chrzan, K L [I07/2007/I-043] [ENY-ARTICLE-2008-187]
The surge arresters diagnostics based on infrared temperature measurement was evaluated. [...]
http://zet10.ipee.pwr.wroc.pl/record/238/files/
Detailed record - Similar records
167. Pollution behaviour of insulators with spiral shaped sheds / Chrzan, K L ; Kindersberger, J [I07/2005/I-010] [ENY-ARTICLE-2008-186]
The paper reviews the experimental investigation of the performance of insulators with spiral shaped sheds under laboratory and field conditions. [...]
http://zet10.ipee.pwr.wroc.pl/record/237/files/
Detailed record - Similar records
168. Verschmutzungsverhalten von Hochspannungsisolatoren und Ableitern / Chrzan, K L [I07/2007/I-005] [ENY-ARTICLE-2008-185]
Von 1980 bis 2005 wurde das Verschmutzungsverhalten unterschiedlicher Hochspannungsisolatoren und Überspannungsableiter im Freiluftprüffeld „Glogów“ untersucht. [...]
http://zet10.ipee.pwr.wroc.pl/record/236/files/
Detailed record - Similar records

Articles : 348 records found   beginprevious159 - 168nextend  jump to record: