Articles

Articles 348 records found  previous11 - 20nextend  jump to record: Search took 0.01 seconds. 
11. Application of the Prony Method for Compensation of Errors in Distance Relays / Trujillo, L ; Conde, A ; Leonowicz, Z [doi: 10.1109/EEEIC.2013.6549580 ] [ENY-ARTICLE-2013-352]
In this paper we propose an application of the Prony method as a filtering technique for distance relays. [...]
http://zet10.ipee.pwr.wroc.pl/record/440/files/
Detailed record - Similar records
12. TSC transformer with asymmetric source and load / Mach, V ; Gono, R ; Leonowicz, Z [ENY-ARTICLE-2013-351]
The paper analyses unconventional connection of a three-phase transformer with asymmetric source and load. [...]
http://zet10.ipee.pwr.wroc.pl/record/439/files/
Detailed record - Similar records
13. Degradation of metal oxide varistors caused by electrical stresses / Chrzan, K L [ENY-ARTICLE-2013-350]
The degradation of ZnO elements under AC or DC operating voltage and impulse current is described. [...]
http://zet10.ipee.pwr.wroc.pl/record/437/files/
Detailed record - Similar records
14. Influence of profile on the pollution performance of ceramic long-rod insulators / Chrzan, K L [ENY-ARTICLE-2013-349]
The long rod insulators with different profiles were shown. [...]
http://zet10.ipee.pwr.wroc.pl/record/436/files/
Detailed record - Similar records
15. Franklin rods - sharp or blunt ? / Chrzan, K L [ENY-ARTICLE-2013-348]
This paper gives the historical background of 250 year old question: should the Franklin rod tip be sharp or blunt ? The earlier works, the new field results from USA and own laboratory experiments are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/435/files/
Detailed record - Similar records
16. The threat caused by fires under high voltage lines / Chrzan, K L ; Wroblewski, Z. [ENY-ARTICLE-2013-347]
The effect of fires on the flashover voltage of power lines has been investigated in Brazil, Mexico, Canada, USA, South Africa, Australia and Poland. [...]
http://zet10.ipee.pwr.wroc.pl/record/434/files/
Detailed record - Similar records
17. HV on-site testing on cables by alternating voltage of variable frequency / Hauschild, W. ; Schierig, S. ; Chrzan, K L [ENY-ARTICLE-2013-346]
Frequency-tuned resonant test systems are, meanwhile, state-of-the-art for on-site testing and diagnostics on high-voltage plastic-insulated cables. [...]
http://zet10.ipee.pwr.wroc.pl/record/433/files/
Detailed record - Similar records
18. Degradation and destruction of ZnO varistors caused by current pulses / Chrzan, K L ; Wroblewski, Z. [ENY-ARTICLE-2013-345]
Although the modern metal oxide elements are resistant to degradation caused by continuous operating voltage the degradation or destruction caused by current impulses, especially lightning currents, is still a serious problem. [...]
http://zet10.ipee.pwr.wroc.pl/record/432/files/
Detailed record - Similar records
19. Effect of acid rain on outdoor insulators / Chrzan, K L ; Andino, J.M. ; Twarowski, R. [ENY-ARTICLE-2013-344]
This paper gives an overview of the acid rain problem in Europe, Poland and the Polish province of Silesia. [...]
http://zet10.ipee.pwr.wroc.pl/record/431/files/
Detailed record - Similar records
20. Temperature monitoring of metal oxide surge arresters / Chrzan, K L ; Hinrichsen, V. [ENY-ARTICLE-2013-343]
Varistor overtemperature above the ambient is an important state parameter of metal oxide surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/430/files/
Detailed record - Similar records

Articles : 348 records found   previous11 - 20nextend  jump to record: