Izolatory

Izolatory Znaleziono 53 rekordów  początekpoprzedni21 - 30następnykoniec  skocz do rekordu: Szukanie trwało 0.01 sekund. 
21. Insulators Glaze Modified by Plasma Processes / Tyman, A ; Pospieszna, J ; Juchniewicz, J [ENY-ARTICLE-2009-232]
Surface properties of electrical insulators are responsible for their behaviour, especially during heavy rains in contaminated areas. [...]
http://zet10.ipee.pwr.wroc.pl/record/291/files/
Rekord szczegółowy - Podobne rekordy
22. Special Insulator for Installation of Optical Phase Conductor on 15 kV Line / Argasinska, H ; Fleszynski, J ; Sojda, E ; Tyman, A [ENY-ARTICLE-2008-231]
Thanks to the recent improvements in the technology of glass fibres and the development of digital data transmission techniques, optical fibres have made their way into power distribution and industry. [...]
http://zet10.ipee.pwr.wroc.pl/record/286/files/
Rekord szczegółowy - Podobne rekordy
23. Steep-front impulse voltage tests of composite insulators / Fleszynski, J ; Sojda, E ; Tyman, A ; Koruba, K [ENY-ARTICLE-2008-228]
It is very important to eliminate improper insulator designs and technological faults. [...]
http://zet10.ipee.pwr.wroc.pl/record/283/files/
Rekord szczegółowy - Podobne rekordy
24. Behaviour of modified insulator surface material under electric stress / Fleszynski, J ; Tyman, A [ENY-ARTICLE-2008-227]
Performance of electrical insulators is strongly dependent on their surface properties. [...]
http://zet10.ipee.pwr.wroc.pl/record/282/files/
Rekord szczegółowy - Podobne rekordy
25. The Effect of the Number of Spacer Insulators on the Breakdown Voltage of Vacuum Insulation / Juchniewicz, J ; Mazurek, B ; Tyman, A [ENY-ARTICLE-2008-226]
It was shown that when extended high voltage vacuum insulation is being considered, the effect of the he number of spacer insulators on the breakdown voltage of the system has to be taken into account. [...]
http://zet10.ipee.pwr.wroc.pl/record/281/files/
Rekord szczegółowy - Podobne rekordy
26. Voltage Endurance Test of Vacuum Insulation for Cryocables / Juchniewicz, J ; Tyman, A [ENY-ARTICLE-2008-225]
Vacuum insulation with cylindrical ceramic spacer insulators has been studied with respect to changes of its ac flashover voltage with time. [...]
http://zet10.ipee.pwr.wroc.pl/record/280/files/
Rekord szczegółowy - Podobne rekordy
27. Changes on Insulator Surface under the Influence of Strong Electric Field in Vacuum / Mazurek, B ; Tyman, A [ENY-ARTICLE-2008-224]
The measurements of flash-over voltages on solid insulation, placed in vacuum have shown the initial flash-over occur at voltages considerably lower than this obtained after multiple flash-over. [...]
http://zet10.ipee.pwr.wroc.pl/record/279/files/
Rekord szczegółowy - Podobne rekordy
28. AC Flashover Voltage in Vacuum for Different Electrode Diameters and Different Pressures / Tyman, A [ENY-ARTICLE-2008-223]
Application of vacuum insulation in cryo-installations, for example cryocables, requires investigations made on specimens and laboratory arrangements which would be very close to those met in practice. [...]
http://zet10.ipee.pwr.wroc.pl/record/278/files/
Rekord szczegółowy - Podobne rekordy
29. Behaviour of Insulators and Surge Arresters at Glogow Pollution Test Station / Chrzan, K L ; Haddad, A [I07/2005/I-005] [ENY-ARTICLE-2008-222]
The paper reports on the pollution performance of different insulators and surge arresters at Glogow test station from 1981 up to 2004. [...]
http://zet10.ipee.pwr.wroc.pl/record/277/files/
Rekord szczegółowy - Podobne rekordy
30. Performance of Composite Insulators Without Sheds under Light Pollution / Chrzan, K L [ENY-ARTICLE-2008-221]
The test of insulators without sheds or with small sheds number at Glogow pollution station was described. [...]
http://zet10.ipee.pwr.wroc.pl/record/276/files/
Rekord szczegółowy - Podobne rekordy

Izolatory : Znaleziono 53 rekordów   początekpoprzedni21 - 30następnykoniec  skocz do rekordu: