Insulators

Insulators 53 records found  beginprevious21 - 30nextend  jump to record: Search took 0.01 seconds. 
21. Insulators Glaze Modified by Plasma Processes / Tyman, A ; Pospieszna, J ; Juchniewicz, J [ENY-ARTICLE-2009-232]
Surface properties of electrical insulators are responsible for their behaviour, especially during heavy rains in contaminated areas. [...]
http://zet10.ipee.pwr.wroc.pl/record/291/files/
Detailed record - Similar records
22. Special Insulator for Installation of Optical Phase Conductor on 15 kV Line / Argasinska, H ; Fleszynski, J ; Sojda, E ; Tyman, A [ENY-ARTICLE-2008-231]
Thanks to the recent improvements in the technology of glass fibres and the development of digital data transmission techniques, optical fibres have made their way into power distribution and industry. [...]
http://zet10.ipee.pwr.wroc.pl/record/286/files/
Detailed record - Similar records
23. Steep-front impulse voltage tests of composite insulators / Fleszynski, J ; Sojda, E ; Tyman, A ; Koruba, K [ENY-ARTICLE-2008-228]
It is very important to eliminate improper insulator designs and technological faults. [...]
http://zet10.ipee.pwr.wroc.pl/record/283/files/
Detailed record - Similar records
24. Behaviour of modified insulator surface material under electric stress / Fleszynski, J ; Tyman, A [ENY-ARTICLE-2008-227]
Performance of electrical insulators is strongly dependent on their surface properties. [...]
http://zet10.ipee.pwr.wroc.pl/record/282/files/
Detailed record - Similar records
25. The Effect of the Number of Spacer Insulators on the Breakdown Voltage of Vacuum Insulation / Juchniewicz, J ; Mazurek, B ; Tyman, A [ENY-ARTICLE-2008-226]
It was shown that when extended high voltage vacuum insulation is being considered, the effect of the he number of spacer insulators on the breakdown voltage of the system has to be taken into account. [...]
http://zet10.ipee.pwr.wroc.pl/record/281/files/
Detailed record - Similar records
26. Voltage Endurance Test of Vacuum Insulation for Cryocables / Juchniewicz, J ; Tyman, A [ENY-ARTICLE-2008-225]
Vacuum insulation with cylindrical ceramic spacer insulators has been studied with respect to changes of its ac flashover voltage with time. [...]
http://zet10.ipee.pwr.wroc.pl/record/280/files/
Detailed record - Similar records
27. Changes on Insulator Surface under the Influence of Strong Electric Field in Vacuum / Mazurek, B ; Tyman, A [ENY-ARTICLE-2008-224]
The measurements of flash-over voltages on solid insulation, placed in vacuum have shown the initial flash-over occur at voltages considerably lower than this obtained after multiple flash-over. [...]
http://zet10.ipee.pwr.wroc.pl/record/279/files/
Detailed record - Similar records
28. AC Flashover Voltage in Vacuum for Different Electrode Diameters and Different Pressures / Tyman, A [ENY-ARTICLE-2008-223]
Application of vacuum insulation in cryo-installations, for example cryocables, requires investigations made on specimens and laboratory arrangements which would be very close to those met in practice. [...]
http://zet10.ipee.pwr.wroc.pl/record/278/files/
Detailed record - Similar records
29. Behaviour of Insulators and Surge Arresters at Glogow Pollution Test Station / Chrzan, K L ; Haddad, A [I07/2005/I-005] [ENY-ARTICLE-2008-222]
The paper reports on the pollution performance of different insulators and surge arresters at Glogow test station from 1981 up to 2004. [...]
http://zet10.ipee.pwr.wroc.pl/record/277/files/
Detailed record - Similar records
30. Performance of Composite Insulators Without Sheds under Light Pollution / Chrzan, K L [ENY-ARTICLE-2008-221]
The test of insulators without sheds or with small sheds number at Glogow pollution station was described. [...]
http://zet10.ipee.pwr.wroc.pl/record/276/files/
Detailed record - Similar records

Insulators : 53 records found   beginprevious21 - 30nextend  jump to record: