Electrical Engineering Wroclaw University of Technology

Electrical Engineering Wroclaw University of Technology 430 records found  beginprevious21 - 30nextend  jump to record: Search took 0.01 seconds. 
21. The threat caused by fires under high voltage lines / Chrzan, K L ; Wroblewski, Z. [ENY-ARTICLE-2013-347]
The effect of fires on the flashover voltage of power lines has been investigated in Brazil, Mexico, Canada, USA, South Africa, Australia and Poland. [...]
http://zet10.ipee.pwr.wroc.pl/record/434/files/
Detailed record - Similar records
22. HV on-site testing on cables by alternating voltage of variable frequency / Hauschild, W. ; Schierig, S. ; Chrzan, K L [ENY-ARTICLE-2013-346]
Frequency-tuned resonant test systems are, meanwhile, state-of-the-art for on-site testing and diagnostics on high-voltage plastic-insulated cables. [...]
http://zet10.ipee.pwr.wroc.pl/record/433/files/
Detailed record - Similar records
23. Degradation and destruction of ZnO varistors caused by current pulses / Chrzan, K L ; Wroblewski, Z. [ENY-ARTICLE-2013-345]
Although the modern metal oxide elements are resistant to degradation caused by continuous operating voltage the degradation or destruction caused by current impulses, especially lightning currents, is still a serious problem. [...]
http://zet10.ipee.pwr.wroc.pl/record/432/files/
Detailed record - Similar records
24. Effect of acid rain on outdoor insulators / Chrzan, K L ; Andino, J.M. ; Twarowski, R. [ENY-ARTICLE-2013-344]
This paper gives an overview of the acid rain problem in Europe, Poland and the Polish province of Silesia. [...]
http://zet10.ipee.pwr.wroc.pl/record/431/files/
Detailed record - Similar records
25. Temperature monitoring of metal oxide surge arresters / Chrzan, K L ; Hinrichsen, V. [ENY-ARTICLE-2013-343]
Varistor overtemperature above the ambient is an important state parameter of metal oxide surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/430/files/
Detailed record - Similar records
26. Pollution flashover of single unit metal oxide arresters / Chrzan, K L ; Koehler, W. [ENY-ARTICLE-2013-342]
Flashover voltage of uniform and non-uniform polluted metal oxide arresters and their porcelain housings without internal parts was measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/429/files/
Detailed record - Similar records
27. Klasyczne piorunochrony Franklina i piorunochrony pseudoaktywne / Chrzan, K L [ENY-ARTICLE-2012-341]
Omówiono rozwój lidera odgórnego i lidera oddolnego pioruna liniowego. [...]
http://zet10.ipee.pwr.wroc.pl/record/428/files/
Detailed record - Similar records
28. Piorunochrony pseudoaktywne / Bazelyan, E M ; Chrzan, K L [ENY-ARTICLE-2012-340]
Opisano własności podstawowych form wyładowań elektrycznych w powietrzu: strimera i lidera. [...]
http://zet10.ipee.pwr.wroc.pl/record/427/files/
Detailed record - Similar records
29. Fault Location in Power Networks with Mixed Feeders using the Complex Space-Phasor and Hilbert-Huang Transform / Bernadić, A ; Leonowicz, Z [http://dx.doi.org/10.1016/j.ijepes.2012.04.012] [ENY-ARTICLE-2012-339]
The paper introduces a practical approach to power system fault location in power networks using advanced fault signal processing. [...]
http://zet10.ipee.pwr.wroc.pl/record/426/files/
Detailed record - Similar records
30. Condition Monitoring & Fault Diagnosis System for Offshore Wind Turbines / Ouadie, B ; Heraud, N ; Leonowicz, Z [Digital Object Identifier: 10.1109/EEEIC.2012.6221389] [ENY-ARTICLE-2012-338]
Due to the technological development, the electronic power progress and economic stake, through the use of Wound Rotor Induction Motor (WRIM) has taken more and more places in different domains (transport, energy production, electric drive. [...]
http://zet10.ipee.pwr.wroc.pl/record/425/files/
Detailed record - Similar records

Electrical Engineering Wroclaw University of Technology : 430 records found   beginprevious21 - 30nextend  jump to record: