Electrical Engineering Wroclaw University of Technology

Electrical Engineering Wroclaw University of Technology 70 records found  1 - 25nextend  jump to record: Search took 0.01 seconds. 
1. Wykorzystanie pakietu FILTR'96 w dydaktyce i projektowaniu cyfrowych filtrów FIR / Lobos, T ; Ruczewski, P ; Szymanda, J [ENY-ARTICLE-2010-294]
W artykule przedstawiono przykładową realizację zadania dydaktycznego w ramach prowadzonych kursów z bloku przedmiotowego "Cyfrowe Przetwarzanie Sygnałów". [...]
http://zet10.ipee.pwr.wroc.pl/record/367/files/
Detailed record - Similar records
2. New Digital Algorithms for On-line Determination of Symmetrical Components in Power Systems / Lobos, T ; Schneider, E [ENY-ARTICLE-2010-293]
Using the Fourier method the Kalman theory and the Walsh functions, non-recursive algorithms for the on-line determination of the basic waveforms of the symmetrical components in three-phase power systems are introduced, investigated and compared. [...]
http://zet10.ipee.pwr.wroc.pl/record/366/files/
Detailed record - Similar records
3. Wyznaczanie częstotliwości zniekształconych sygnałów w układach przekształtnikowych / Lobos, T ; Rezmer, J [ENY-ARTICLE-2010-288]
Nowoczesne półprzewodnikowe przekształtniki częstotliwości, stosowane do zasilania silników asynchronicznych, charakteryzują się zniekształconymi przebiegami napięć wyjściowych. [...]
http://zet10.ipee.pwr.wroc.pl/record/359/files/
Detailed record - Similar records
4. Time-varying signal parameters for assessment of disturbances in wind energy systems / Lobos, T ; Schegner, P ; Sikorski, T [ENY-ARTICLE-2009-270]
This paper proposes some extended method for assessment of transient disturbances in wind energy systems. [...]
http://zet10.ipee.pwr.wroc.pl/record/338/files/
Detailed record - Similar records
5. Nonlinear regression applied for power quality disturbances characterization in grids with wind generators / Janik, P ; Lobos, T ; Rezmer, J ; Waclawek, Z [I07/2009/I-035] [ENY-ARTICLE-2009-267]
The impact of wind generation on the electrical system should be assessed to figure out potential hazards to system operation and deterioration of power quality indices. [...]
http://zet10.ipee.pwr.wroc.pl/record/335/files/
Detailed record - Similar records
6. Adaptation of SVD and Prony method for precise computation of current components in networks with wind generation. / Janik, P ; Rezmer, J ; Ruczewski, P ; Waclawek, Z ; et al [I07/2009/I-037] [ENY-ARTICLE-2009-266]
Precise computation of current components is a key prerequisite for reliable assessment of power quality. [...]
http://zet10.ipee.pwr.wroc.pl/record/334/files/
Detailed record - Similar records
7. Assessment of transient disturbances in HV systems with single-phase autoreclosures / Lobos, T ; Schegner, P ; Sikorski, T [ENY-ARTICLE-2009-265]
This paper proposes some extended method for assessment of transient disturbances in HV system with single-phase autoreclosures. [...]
http://zet10.ipee.pwr.wroc.pl/record/333/files/
Detailed record - Similar records
8. Computation of Voltage Sag Initiation with Fourier based Algorithm, Kalman Filter and Wavelets / Amaris, H ; Alvarez, A ; Florez, D ; Lobos, T ; et al [ENY-ARTICLE-2009-264]
Dynamic Voltage Restorers (DVR) have been successfully applied for voltage dip mitigation in the last years. [...]
http://zet10.ipee.pwr.wroc.pl/record/332/files/
Detailed record - Similar records
9. Computation of Spectral Components in System with Wind Generation Unit / Janik, P ; Lobos, T ; Rezmer, J ; Schegner, P ; et al [ENY-ARTICLE-2009-263]
Signal parameters estimation is an important prerequisite for assessment of power quality (PQ) indices. [...]
http://zet10.ipee.pwr.wroc.pl/record/331/files/
Detailed record - Similar records
10. Power Quality Analysis of Grid-Connected Wind Turbine System / Janik, P ; Lobos, T ; Rezmer, J ; Sikorski, T [ENY-ARTICLE-2009-262]
In this paper time-frequency methods have been investigated for complex investigations of transient states in wind power plants. [...]
http://zet10.ipee.pwr.wroc.pl/record/330/files/
Detailed record - Similar records
11. Power Distortion Issues in Wind Turbine Power Systems Under Transient States / Lobos, T ; Rezmer, J ; Sikorski, T ; Waclawek, Z [AZ I07/2009/I-001] [ENY-ARTICLE-2009-254]
In this paper time-frequency methods have been investigated for complex investigations of transient states in wind power plants. [...]
http://zet10.ipee.pwr.wroc.pl/record/316/files/
Detailed record - Similar records
12. Analysis of non-stationary electric signals using the S-transform / Leonowicz, Z ; Lobos, T ; Wozniak, K [ENY-ARTICLE-2009-253]
Purpose – The purpose of this paper is to compare the accuracy of tracking the amplitude and frequency changes of non-stationary electric signals. [...]
http://zet10.ipee.pwr.wroc.pl/record/314/files/
Detailed record - Similar records
13. Identification of Out-of-Step Operation of Synchronous Machines Using High Resolution Spectrum Estimation Methods / Koglin, H J ; Leonowicz, Z ; Lobos, T [RK I07/2002/I-046] [ENY-ARTICLE-2009-252]
The out-of-step operation conditions of a synchronous machine may occur as a result of a power system three-phase fault. [...]
http://zet10.ipee.pwr.wroc.pl/record/313/files/
Detailed record - Similar records
14. Modern spectral analysis of non-stationary signals in electrical power systems / Leonowicz, Z ; Lobos, T ; Schegner, P [RZ I07/2002/I-048] [ENY-ARTICLE-2009-251]
A novel approach to harmonic and interharmonic analysis, based on the “subspace” methods, is proposed. [...]
http://zet10.ipee.pwr.wroc.pl/record/312/files/
Detailed record - Similar records
15. Advanced spectral analysis of out-of-step operation of synchronous machines / Leonowicz, Z ; Lobos, T [RZ I07/2003/I-068] [ENY-ARTICLE-2009-250]
The out-of-step operation conditions of a synchronous machine may occur as a result of a power system three-phase fault. [...]
http://zet10.ipee.pwr.wroc.pl/record/311/files/
Detailed record - Similar records
16. Automatic Fault Classification in Power Electronics Using Time-Frequency Distribution and Neural Networks / Leonowicz, Z ; Lobos, T [RZ I07/2003/I-077] [ENY-ARTICLE-2009-249]
A new method of fault analysis and detection by signal classification in frequency converters is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/310/files/
Detailed record - Similar records
17. Spectrum estimation methods for signal analysis in the supply system of DC arc furnace / Leonowicz, Z ; Lobos, T ; Rezmer, J [RZ I07/2005/I-023] [ENY-ARTICLE-2009-242]
In this paper, Prony and root-MUSIC methods are applied for analysis of waveforms from the DC arc furnace supply. [...]
http://zet10.ipee.pwr.wroc.pl/record/303/files/
Detailed record - Similar records
18. Waveform Distortions due to AC/DC converters feeding DC arc furnaces / Bracale, A ; Carpinelli, G ; Leonowicz, Z ; Lobos, T ; et al [RK I07/2005/I-039] [ENY-ARTICLE-2009-241]
The line-commutated converters cause significant harmonic distortions in electrical power systems. [...]
http://zet10.ipee.pwr.wroc.pl/record/302/files/
Detailed record - Similar records
19. Automated Classification of Power Quality Disturbances using SVM and RBF Networks / Janik, P ; Lobos, T [ENY-ARTICLE-2009-239]
The authors propose a new method of power quality classification using SVM (Support Vector Machine) neural networks. [...]
http://zet10.ipee.pwr.wroc.pl/record/300/files/
Detailed record - Similar records
20. Analysis of traction system time-varying signals using ESPRIT subspace spectrum estimation method / Leonowicz, Z ; Lobos, T [I07/2006/I-090] [ENY-ARTICLE-2008-190]
Auxiliary static converters in transportation power systems generate not only characteristic harmonics but also non characteristic harmonics and interharmonics. [...]
http://zet10.ipee.pwr.wroc.pl/record/241/files/
Detailed record - Similar records
21. Power quality evaluation using advanced spectrum estimation methods / Leonowicz, Z ; Lobos, T [I07/2006/I-082] [ENY-ARTICLE-2008-174]
The authors show that the use of high-resolution spectrum estimation methods instead of Fourier-based techniques can improve the accuracy of measurement of spectral parameters of distorted waveforms encountered in power systems, in particular the estimation of the power quality indices (such as inter/harmonic groups and subgroups) . [...]
http://zet10.ipee.pwr.wroc.pl/record/223/files/
Detailed record - Similar records
22. Analysis of influence of power quality disturbances using a neuro-fuzzy systems / Janik, P ; Leonowicz, Z ; Lobos, T ; Waclawek, Z [RZ I07/2007/I-025] [ENY-ARTICLE-2008-172]
The authors propose an automated neuro-fuzzy system approach (with neural network subsystem) to power quality assessment incorporating equipment susceptibility patterns. [...]
http://zet10.ipee.pwr.wroc.pl/record/221/files/
Detailed record - Similar records
23. Wavelets and Prony Method for Disturbance Detection in Wind Farms / Lobos, T ; Rezmer, J ; Janik, P ; Amaris, H ; et al [ENY-ARTICLE-2008-155]
Wind generator impact on power quality is crucial for power system operation. [...]
http://zet10.ipee.pwr.wroc.pl/record/202/files/
Detailed record - Similar records
24. Echtzeitberechnung der modalen Drehstromkomponenten nach plötzlichen Zustandsänderungen / Hosemann, G ; Schneider, E ; Lobos, T [I08/1987/I-409] [ENY-ARTICLE-2008-119]
Zur schnellen digitalen Ermittlung der Modalkomponenten in Drehstromsystemen werden in des Regel nichtrekursive Filterverfahren verwendet. [...]
http://zet10.ipee.pwr.wroc.pl/record/154/files/
Detailed record - Similar records
25. Time-Frequency Representation for Non-Stationary Phenomena in Electrical Engineering / Sikorski, T ; Ruczewski, P ; Lobos, T [I07/2004/I-018] [ENY-ARTICLE-2008-118]
The paper introduces two-dimensional method of observation and diagnosis of non-stationary signals in electrical engineering. [...]
http://zet10.ipee.pwr.wroc.pl/record/153/files/
Detailed record - Similar records

Electrical Engineering Wroclaw University of Technology : 70 records found   1 - 25nextend  jump to record:
Haven't found what you were looking for? Try your search on other servers:
Lobos, T in Google Books
Lobos, T in Google Scholar
Lobos, T in Google Web
Lobos, T in INSPEC