Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 13 rekordów  1 - 10następny  skocz do rekordu: Szukanie trwało 0.02 sekund. 
1. Pollution flashover of single unit metal oxide arresters / Chrzan, K L ; Koehler, W. [ENY-ARTICLE-2013-342]
Flashover voltage of uniform and non-uniform polluted metal oxide arresters and their porcelain housings without internal parts was measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/429/files/
Rekord szczegółowy - Podobne rekordy
2. Impulse flashover of strings containing standard and semi-conducting disc insulators / Chrzan, K L ; Elsaesser, O [ENY-ARTICLE-2012-324]
Insulators with semi-conducting glazes (SCG insulators) are used mainly in heavily polluted areas. [...]
http://zet10.ipee.pwr.wroc.pl/record/411/files/
Rekord szczegółowy - Podobne rekordy
3. Thermische Eigenshaften von Fremdschichten / Chrzan, K L ; Koehler, W [ENY-ARTICLE-2012-317]
In the paper the conductive behavior of saturated and unsaturated electrolytic solutions as a function of temperature is discussed. [...]
http://zet10.ipee.pwr.wroc.pl/record/404/files/
Rekord szczegółowy - Podobne rekordy
4. Internal Arcing Test on Polluted High Voltage Surge Arresters / Chrzan, K L ; Kohler, W ; Feser, K [ENY-ARTICLE-2009-234]
A test to prove the performance of extremely non-uniform polluted single unit metal oxide (MO) and gapped arresters (SiCA) is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/293/files/
Rekord szczegółowy - Podobne rekordy
5. Pollution Performance of 110 kV Metal Oxide Arresters / Chrzan, K L ; Pohl, Z ; Grzybowski, S ; Kohler, W [ENY-ARTICLE-2008-216]
Pollution test results of single unit 110 kV metal oxide surge arresters with porcelain housing according to the solid layer and salt fog methods are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/270/files/
Rekord szczegółowy - Podobne rekordy
6. Behaviour of Zinc Oxide Surge Arresters Under Pollution / Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L [ENY-ARTICLE-2008-214]
This paper presents results of pollution tests with A. [...]
http://zet10.ipee.pwr.wroc.pl/record/268/files/
Rekord szczegółowy - Podobne rekordy
7. Behaviour of zinc oxide surge arresters under pollution / Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L [I07/1990/I-114] [ENY-ARTICLE-2008-213]
This paper presents results of pollution tests with AC voltages which were carried out with a multi-unit zinc oxide arrester. [...]
http://zet10.ipee.pwr.wroc.pl/record/267/files/
Rekord szczegółowy - Podobne rekordy
8. Diagnostics of high voltage metal oxide arresters procedure errors / Chrzan, K L ; Koehler, W [I07/2000/I-059] [ENY-ARTICLE-2008-193]
A technique has been described which can determine ac resistive current directly or by obtaining the watt loss of the test specimen and dividing by the true rms (trms) value or the applied voltage. [...]
http://zet10.ipee.pwr.wroc.pl/record/247/files/
Rekord szczegółowy - Podobne rekordy
9. Fuzzy Logic Application to Out-Of-Step Protection of Generators / Rebizant, W ; Feser, K [I08/2001/I-110] [ENY-ARTICLE-2008-163]
Efficient protection scheme against out-of-step (OS) conditions based on fuzzy logic (FL) technique is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/210/files/
Rekord szczegółowy - Podobne rekordy
10. Out-of-Step Protection with AI Methods / Rebizant, W ; Feser, K [I08/2001/I-033] [ENY-ARTICLE-2008-161]
In the paper the results of investigations on the application of Artificial Intelligence (AI) methods to the out-ofstep (OS) protection of synchronous machines are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/208/files/
Rekord szczegółowy - Podobne rekordy

Repozytorium W. Elektrycznego Politechniki Wrocławskiej : Znaleziono 13 rekordów   1 - 10następny  skocz do rekordu:
Jeżeli nie znaleziono tego czego szukasz, spróbuj szukać na innych serwerach:
Stuttgart University w Google Books
Stuttgart University w Google Scholar
Stuttgart University w Google Web
Stuttgart University w INSPEC