Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 305 rekordów  początekpoprzedni34 - 43następnykoniec  skocz do rekordu: Szukanie trwało 0.02 sekund. 
34. Artificial aging of polymer insulation surface in a clean fog chamber and its evaluation / Pilling, J ; Chran, K ; Hofmann, J ; Baersch, R [ENY-ARTICLE-2012-323]
It is reported about electrical performance of room temperature vulcanizing (RTV) silicone rubber insulator coatings and epoxy insulators under accelerating aging in a clean chamber. [...]
http://zet10.ipee.pwr.wroc.pl/record/410/files/
Rekord szczegółowy - Podobne rekordy
35. The role of gases in the pollution problem of outdoor insulators / Chrzan, K L [ENY-ARTICLE-2012-322]
Experiments on the absorption of SO2 and CO2 by destilled water and by some electrolytic solutions have been conducted in laboratory and on the site. [...]
http://zet10.ipee.pwr.wroc.pl/record/409/files/
Rekord szczegółowy - Podobne rekordy
36. Influence of moisture and partial discharges on the degradation of high-voltage surge arresters. / Chrzan, K L [ENY-ARTICLE-2012-321]
This paper reports the influence of moisture and internal partial discharges on the degradation of metal oxide varistors in high-voltage surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/408/files/
Rekord szczegółowy - Podobne rekordy
37. Pollution flashover of long rod insulators with different profiles. / Chrzan, K L ; Vokalek, J ; Sklenicka, V ; Petrusch, W ; et al [ENY-ARTICLE-2012-320]
Pollution test of four long rod insulators with different shapes were carried out according to flow on, salt fog and solid layer methods. [...]
http://zet10.ipee.pwr.wroc.pl/record/407/files/
Rekord szczegółowy - Podobne rekordy
38. Creeping discharges / Chrzan, K L ; Trzęsicki, P [ENY-ARTICLE-2012-319]
Creeping discharges were studied on a cylinder model insulator. [...]
http://zet10.ipee.pwr.wroc.pl/record/406/files/
Rekord szczegółowy - Podobne rekordy
39. PSPICE appliction for modelling of cap and pin insulator strings / Chrzan, K L ; Rebizant, W [ENY-ARTICLE-2012-318]
The use of PSPICE program in HV engineering is shown. [...]
http://zet10.ipee.pwr.wroc.pl/record/405/files/
Rekord szczegółowy - Podobne rekordy
40. Thermische Eigenshaften von Fremdschichten / Chrzan, K L ; Koehler, W [ENY-ARTICLE-2012-317]
In the paper the conductive behavior of saturated and unsaturated electrolytic solutions as a function of temperature is discussed. [...]
http://zet10.ipee.pwr.wroc.pl/record/404/files/
Rekord szczegółowy - Podobne rekordy
41. History of lightning protection in Poland / Chrzan, K L ; Marciniak, R [ENY-ARTICLE-2012-316]
The history of lightning protection in Poland and its short overview in the world is given. [...]
http://zet10.ipee.pwr.wroc.pl/record/403/files/
Rekord szczegółowy - Podobne rekordy
42. History of lightning protection in Poland / Chrzan, K L ; Marciniak, R [ENY-ARTICLE-2012-315]
The history of lightning protection in Poland and its short overview in the world is given. [...]
http://zet10.ipee.pwr.wroc.pl/record/402/files/
Rekord szczegółowy - Podobne rekordy
43. Inefficacité des Paratonnerres à Avance d’Amorçage / Chrzan, K L ; Teguar, M [ENY-ARTICLE-2012-314]
Tests on three early streamer emission (ESE) terminals, manufactured by different firms, were carried out. [...]
http://zet10.ipee.pwr.wroc.pl/record/401/files/
Rekord szczegółowy - Podobne rekordy

Repozytorium W. Elektrycznego Politechniki Wrocławskiej : Znaleziono 305 rekordów   początekpoprzedni34 - 43następnykoniec  skocz do rekordu:
Jeżeli nie znaleziono tego czego szukasz, spróbuj szukać na innych serwerach:
university w Google Books
university w Google Scholar
university w Google Web
university w INSPEC