Elektrotechnik TU Wroclaw

Elektrotechnik TU Wroclaw 100 Datensätze gefunden  1 - 25nächsteEnde  gehen zum Datensatz: Die Suche hat 0.01 Sekunden gedauert. 
1. Analysis of Mathematical Modeling of PV Module with MPPT Algorithm / Chitti Babu, B ; Cermak, T ; Gurjar, S ; Leonowicz, Z ; et al [ENY-ARTICLE-2015-364]
This paper presents the mathematical modeling of photovoltaic (PV) module with the effective comparison of two popular maximum power point tracking (MPPT) techniques; Generally, Maximum Power Point Tracking (MPPT) techniques are used in PV System to extract maximum possible power which in turn depends on solar irradiance and temperature of PV module. [...]
http://zet10.ipee.pwr.wroc.pl/record/457/files/
Details vom Eintrag - Ähnliche Datensätze
2. AC Power and Energy Measurements based on Physical Definitions / Kolanko, J ; Leonowicz, Z ; Ladniak, L ; Musz, P ; et al [ENY-ARTICLE-2015-363]
The article presents the AC power measurements based on physical definitions as introduced by the draft German standard DIN 40110 in 1970 and its practical application as a power signal processor. [...]
http://zet10.ipee.pwr.wroc.pl/record/456/files/
Details vom Eintrag - Ähnliche Datensätze
3. Analysis of SDFT based phase detection system for grid synchronization of distributed generation systems / Chitti Babu, B ; Sridharan, K ; Rosolowski, E ; Leonowicz, Z [http://dx.doi.org/10.1016/j.jestch.2014.07.005] [ENY-PREPRINT-2014-015]
A fast and exact detection of phase and fundamental frequency of grid voltage/current is essential for calculating accurate reference signal in order to implement the control algorithm of inverter-interfaced distributed generation (DG) system and realize precise harmonic compensation. [...]
http://zet10.ipee.pwr.wroc.pl/record/455/files/
Details vom Eintrag - Ähnliche Datensätze
4. Analysis of Recursive DFT Filtering Based Grid Synchronization of Distributed Generation System / Chitti Babu, B ; Sridharan, K ; Rosolowski, E ; Leonowicz, Z [I08/2014/I-069] [ENY-PREPRINT-2014-014]
A converter-interfaced distributed generation (DG) system, like, wind power system, photovoltaic (PV) and micro-turbine-generator system, requires a fast and exact detection of phase and fundamental frequency of grid current in order to implement the control algorithm of power converters by generating reference currents signals. [...]
http://zet10.ipee.pwr.wroc.pl/record/454/files/
Details vom Eintrag - Ähnliche Datensätze
5. Determining of Fault Locations with Hilbert – Huang Transformation on XLPE Cables between Land and Offshore Substations / Bernadić, A ; Leonowicz, Z [ENY-ARTICLE-2014-362]
Using of mathematical transformations and digital signal processing (DSP) methods of recorded voltage and currents in power systems in order to extract important informations about physical processes is already known. [...]
http://zet10.ipee.pwr.wroc.pl/record/453/files/
Details vom Eintrag - Ähnliche Datensätze
6. Wide-area system of registration and processing of power quality data in power grid with distributed generation Part I. System description, functional tests and synchronous recordings Part II. Localization and tracking of the sources of disturbances / Leonowicz, Z ; Rezmer, J ; Sikorski, T ; Szymanda, J ; et al [ENY-ARTICLE-2014-361]
This paper presents the developed and built comprehensive system of registration, archiving and data processing for the wide-area monitoring of power quality in a separated part of real power grid with distributed renewable generation. [...]
http://zet10.ipee.pwr.wroc.pl/record/452/files/
Details vom Eintrag - Ähnliche Datensätze
7. Assessment of Power Quality in Wind Power Systems / Leonowicz, Z [DOI:10.1109/EEEIC.2011.5874665 ] [ENY-ARTICLE-2013-360]
Wind power generation systems influence power quality in a very specific manner creating the requirements for detailed and correct analysis of disturbances caused by wind generators. [...]
http://zet10.ipee.pwr.wroc.pl/record/451/files/
Details vom Eintrag - Ähnliche Datensätze
8. Analysis of Sub-Harmonics in Power Systems / Leonowicz, Z [10.1109/EEEIC.2010.5489951 ] [ENY-ARTICLE-2013-354]
With a wide range of power electronics-related applications in power systems, harmonic currents are increasing at an alarming rate which has greatly deteriorated the power quality in electrical power networks. [...]
http://zet10.ipee.pwr.wroc.pl/record/443/files/
Details vom Eintrag - Ähnliche Datensätze
9. Error Compensation in Distance Relays Caused by Wind Power Plants in the Power Grid / Trujillo, L ; Conde, A ; Leonowicz, Z [http://www.sciencedirect.com/science/article/pii/S0378779613002198] [ENY-PREPRINT-2013-013]
This article presents the Prony method as a filtering technique for distance relays. [...]
http://zet10.ipee.pwr.wroc.pl/record/442/files/
Details vom Eintrag - Ähnliche Datensätze
10. Application of the Prony Method for Compensation of Errors in Distance Relays / Trujillo, L ; Conde, A ; Leonowicz, Z [doi: 10.1109/EEEIC.2013.6549580 ] [ENY-ARTICLE-2013-352]
In this paper we propose an application of the Prony method as a filtering technique for distance relays. [...]
http://zet10.ipee.pwr.wroc.pl/record/440/files/
Details vom Eintrag - Ähnliche Datensätze
11. TSC transformer with asymmetric source and load / Mach, V ; Gono, R ; Leonowicz, Z [ENY-ARTICLE-2013-351]
The paper analyses unconventional connection of a three-phase transformer with asymmetric source and load. [...]
http://zet10.ipee.pwr.wroc.pl/record/439/files/
Details vom Eintrag - Ähnliche Datensätze
12. Fault Location in Power Networks with Mixed Feeders using the Complex Space-Phasor and Hilbert-Huang Transform / Bernadić, A ; Leonowicz, Z [http://dx.doi.org/10.1016/j.ijepes.2012.04.012] [ENY-ARTICLE-2012-339]
The paper introduces a practical approach to power system fault location in power networks using advanced fault signal processing. [...]
http://zet10.ipee.pwr.wroc.pl/record/426/files/
Details vom Eintrag - Ähnliche Datensätze
13. Condition Monitoring & Fault Diagnosis System for Offshore Wind Turbines / Ouadie, B ; Heraud, N ; Leonowicz, Z [Digital Object Identifier: 10.1109/EEEIC.2012.6221389] [ENY-ARTICLE-2012-338]
Due to the technological development, the electronic power progress and economic stake, through the use of Wound Rotor Induction Motor (WRIM) has taken more and more places in different domains (transport, energy production, electric drive. [...]
http://zet10.ipee.pwr.wroc.pl/record/425/files/
Details vom Eintrag - Ähnliche Datensätze
14. Intelligent wireless street lighting system / Leccese, F ; Leonowicz, Z [Digital Object Identifier: 10.1109/EEEIC.2012.6221515] [ENY-ARTICLE-2012-337]
We propose an innovative wireless street lighting system with optimized management and efficiency. [...]
http://zet10.ipee.pwr.wroc.pl/record/424/files/
Details vom Eintrag - Ähnliche Datensätze
15. Assessing the benefits and risks of application of inverter drives in industry / Leonowicz, Z ; Lempart, A [Digital Object Identifier: 10.1109/EEEIC.2012.6221562] [ENY-ARTICLE-2012-336]
This paper presents the impact assessment of converters installed in an industrial plant on the power quality in internal power grid of the plant. [...]
http://zet10.ipee.pwr.wroc.pl/record/423/files/
Details vom Eintrag - Ähnliche Datensätze
16. Impact of Characteristics of Block-Transformers on Inrush Currents and Voltage Distortions at the Connection Point of Wind Parks / Bernadić, A ; Brnadić, I ; Leonowicz, Z [Digital Object Identifier: 10.1109/EEEIC.2012.6221522] [ENY-ARTICLE-2012-335]
In the procedure of connecting large wind parks (WP) to the external power grid, TSO's or DSO's request is that WPs in operation do not excessively affect the power quality in the connection point. [...]
http://zet10.ipee.pwr.wroc.pl/record/422/files/
Details vom Eintrag - Ähnliche Datensätze
17. Power line fault location using the Complex Space-Phasor and Hilbert-Huang Transform / Bernadić, A ; Leonowicz, Z [I07/2011/I-024] [ENY-PREPRINT-2011-012]
Fault location finding in power system is very important problem in power system monitoring. [...]
http://zet10.ipee.pwr.wroc.pl/record/374/files/
Details vom Eintrag - Ähnliche Datensätze
18. Power Quality Report in MV and HV networks / Leonowicz, Z [ENY-REPORT-2010-003]
Example of a power quality report related to generator unit and 110 kV transmission line.
http://zet10.ipee.pwr.wroc.pl/record/372/files/
Details vom Eintrag - Ähnliche Datensätze
19. Raport o jakości energii / Leonowicz, Z [ENY-REPORT-2010-002]
Przykładowy raport oceny jakości energii w sieci SN 10,5 kV i WN 110 KV.
http://zet10.ipee.pwr.wroc.pl/record/371/files/
Details vom Eintrag - Ähnliche Datensätze
20. Renewable Energy Sources in Poland / Leonowicz, Z [ENY-TEACHING-2010-037]
Status of RES in Poland in 2010. [...]
http://zet10.ipee.pwr.wroc.pl/record/370/files/
Details vom Eintrag - Ähnliche Datensätze
21. Analysis of Distorted Waveforms in Power Converter Systems / Rezmer, J ; Leonowicz, Z [ENY-PREPRINT-2010-011]
The paper presents a method of determining the frequency developed and based on the Prony model. [...]
http://zet10.ipee.pwr.wroc.pl/record/369/files/
Details vom Eintrag - Ähnliche Datensätze
22. Comparison between DFT, Adaptive Window DFT and EDFT for Power Quality Frequency Spectrum Analysis / Grossoni, M ; Giarnetti, S ; Leccese, F ; Leonowicz, Z [DOI: 10.13140/2.1.3741.1849] [ENY-ARTICLE-2010-292]
Spectral leakage and picket-fence effects associated with the system fundamental frequency variation and improperly selected sampling time window prevents a direct application of the DFT algorithm with a constant sampling rate. [...]
http://zet10.ipee.pwr.wroc.pl/record/364/files/
Details vom Eintrag - Ähnliche Datensätze
23. Wavelets and Hilbert Transform for detection of short disturbances in electrical power networks / Caciotta, M ; Giarnetti, S ; Leccese, F ; Leonowicz, Z [ENY-ARTICLE-2010-287]
In electrical energy power network, disturbances can cause problems in electronic devices therefore their monitoring is fundamental to properly design the protection and compensation devices. [...]
http://zet10.ipee.pwr.wroc.pl/record/357/files/
Details vom Eintrag - Ähnliche Datensätze
24. Control and Grid Synchronization for Distributed Power Generation Systems / Leonowicz, Z [ENY-TEACHING-2010-035]
Overview--- Main DPGS structures, PV and fuel cell (FC) system, Classification of wind turbine (WT) systems with regard to the use of power electronics, Control structures for grid-side converter , Characteristics of control strategies under grid fault conditions , Grid synchronization methods.
http://zet10.ipee.pwr.wroc.pl/record/351/files/
Details vom Eintrag - Ähnliche Datensätze
25. Power-Electronic Systems for the Grid Integration of Renewable Energy Sources / Leonowicz, Z [ENY-TEACHING-2010-034]
--Outline-- New trends in power electronics for the integration of wind and photovoltaic Review of the appropriate storage-system technology Future trends in renewable energy systems based on reliability and maturity --Introduction-- Increasing number of renewable energy sources and distributed generators New strategies for the operation and management of the electricity grid Improve the power-supply reliability and quality Liberalization of the grids leads to new management structures.
http://zet10.ipee.pwr.wroc.pl/record/350/files/
Details vom Eintrag - Ähnliche Datensätze

Elektrotechnik TU Wroclaw : 100 Datensätze gefunden   1 - 25nächsteEnde  gehen zum Datensatz:
Haben Sie nicht gefunden was Sie suchten? Versuchen Sie Ihre Suche auf anderen Servern:
Leonowicz, Z in Google Books
Leonowicz, Z in Google Scholar
Leonowicz, Z in Google Web
Leonowicz, Z in INSPEC