Electrical Engineering Wroclaw University of Technology

Electrical Engineering Wroclaw University of Technology 11 records found  1 - 10next  jump to record: Search took 0.02 seconds. 
1. Fuzzy Set Approach to Transformer Differential Relay / Wiszniewski, A ; Kasztenny, B [ISBN: 0-85296-559-1] [ENY-ARTICLE-2008-210]
In the process of decision making by a transformer differential relay often occurs a measure of uncertainty. [...]
http://zet10.ipee.pwr.wroc.pl/record/264/files/
Detailed record - Similar records
2. Real-Time Modelling and Digital Implementation of Fuzzy-Logic Controllers / Kasztenny, B ; Hatziadoniu, C ; Wiszniewski, A [ENY-ARTICLE-2008-209]
This paper is concerned with the numerical optimization of the Fuzzy Logic Controller (FLC) for both its efficient simulation and easy real-time implementation. [...]
http://zet10.ipee.pwr.wroc.pl/record/263/files/
Detailed record - Similar records
3. Distance Digital Algorithm Immune to Saturation of Current Transformer / Wiszniewski, A ; Szafran, J [I08/1989/I-044] [ENY-ARTICLE-2008-206]
Saturation of current transformers due to slowly decaying primary current D. [...]
http://zet10.ipee.pwr.wroc.pl/record/260/files/
Detailed record - Similar records
4. Calculation of Current Transformer Transient Errors / Wiszniewski, A [ENY-ARTICLE-2008-205]
Transient saturation of current transformers may cause maloperation of protective devices. [...]
http://zet10.ipee.pwr.wroc.pl/record/259/files/
Detailed record - Similar records
5. Transverse Interference Voltages on Secondary Protection Wiring at Substations / Wiszniewski, A ; Marczonek, S [ENY-ARTICLE-2008-204]
This paper presents simple equivalent circuits which enables calculation of expected values of transverse interference voltages on various secondary circuits at Substations. [...]
http://zet10.ipee.pwr.wroc.pl/record/258/files/
Detailed record - Similar records
6. CT saturation correction based on the estimated CT saturation time constant / Rebizant, W ; Wiszniewski, A ; Schiel, L [I08/2008/I-021] [ENY-ARTICLE-2008-203]
A new method for CT saturation correction is presented that is based on an on-line estimation of the CT magnetizing inductance. [...]
http://zet10.ipee.pwr.wroc.pl/record/257/files/
Detailed record - Similar records
7. Correction of Current Transformer Transient Performance / Wiszniewski, A ; Rebizant, W ; Schiel, L [ENY-ARTICLE-2008-202]
If a current transformer (CT) saturates while transforming the heavy primary current, in each period, there are sections when the magnetic core is unsaturated and transformation is correct, and when it is saturated, it causes enormous errors. [...]
http://zet10.ipee.pwr.wroc.pl/record/256/files/
Detailed record - Similar records
8. New Criteria of Voltage Stability Margin for the Purpose of Load Shedding / Wiszniewski, A [ENY-ARTICLE-2008-201]
Voltage instability is a phenomenon which often contributes to the development of power system disturbances. [...]
http://zet10.ipee.pwr.wroc.pl/record/255/files/
Detailed record - Similar records
9. Ultrasaturation Phenomenon in Power Transformers—Myths and Reality / Wiszniewski, A ; Rebizant, W ; Bejmert, D ; Schiel, L [ENY-ARTICLE-2008-199]
In this paper, the ultrasaturation phenomenon of power transformers during their energization is studied. [...]
http://zet10.ipee.pwr.wroc.pl/record/253/files/
Detailed record - Similar records
10. How to Reduce Errors of Distance Fault Locating Algorithms / Wiszniewski, A [ENY-ARTICLE-2008-198]
Distance fault locating digital algorithms are often based on the processing of fundamental components which are contained in the currents and Voltages. [...]
http://zet10.ipee.pwr.wroc.pl/record/252/files/
Detailed record - Similar records

Electrical Engineering Wroclaw University of Technology : 11 records found   1 - 10next  jump to record:
Haven't found what you were looking for? Try your search on other servers:
Wiszniewski, A in Google Books
Wiszniewski, A in Google Scholar
Wiszniewski, A in Google Web
Wiszniewski, A in INSPEC