Elektrotechnik TU Wroclaw

Elektrotechnik TU Wroclaw 7 Datensätze gefunden  Die Suche hat 0.02 Sekunden gedauert. 
1. TSC transformer with asymmetric source and load / Mach, V ; Gono, R ; Leonowicz, Z [ENY-ARTICLE-2013-351]
The paper analyses unconventional connection of a three-phase transformer with asymmetric source and load. [...]
http://zet10.ipee.pwr.wroc.pl/record/439/files/
Details vom Eintrag - Ähnliche Datensätze
2. Komputerowe metody analizy elektromagnetycznych stanów przejściowych. Przykłady. / Rosolowski, E [ENY-TEACHING-2009-033]
Zamieszczone przykłady są uzupełnieniem materiału zawartego w książce Komputerowe metody analizy elektromagnetycznych stanów przejściowych, Oficyna Wydawnicza Politechniki Wrocławskiej, Wrocław 2009. [...]
http://zet10.ipee.pwr.wroc.pl/record/327/files/
Details vom Eintrag - Ähnliche Datensätze
3. CT saturation correction based on the estimated CT saturation time constant / Rebizant, W ; Wiszniewski, A ; Schiel, L [I08/2008/I-021] [ENY-ARTICLE-2008-203]
A new method for CT saturation correction is presented that is based on an on-line estimation of the CT magnetizing inductance. [...]
http://zet10.ipee.pwr.wroc.pl/record/257/files/
Details vom Eintrag - Ähnliche Datensätze
4. Accurate Location of Faults on Three-Terminal Line with Use of Three-End Unsynchronised Measurements / Izykowski, J ; Rosolowski, E ; Molag, R ; Balcerek, P ; et al [ENY-ARTICLE-2008-157]
This paper presents a new fault location algorithm for three-terminal line utilising unsynchronised measurements of three-end currents and voltages. [...]
http://zet10.ipee.pwr.wroc.pl/record/204/files/
Details vom Eintrag - Ähnliche Datensätze
5. A New Fault Location Algorithm for Use with Current Differential Protective Relays of Two-Terminal Line / Izykowski, J ; Rosolowski, E ; Saha, M [ENY-ARTICLE-2008-156]
A new fault location algorithm utilising synchronised measurements of two-end currents and one-end voltage is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/203/files/
Details vom Eintrag - Ähnliche Datensätze
6. ANN-based Detection of OS Conditions in Power System / Rebizant, W [I08/2000/I-133] [ENY-ARTICLE-2008-152]
In the paper a new neural network based out-of-step protection scheme is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/194/files/
Details vom Eintrag - Ähnliche Datensätze
7. Detection of the Fundamental Harmonic of Distorted Signals using Min-Norm Method / Lobos, T ; Leonowicz, Z ; Piotrowicz, J [ENY-ARTICLE-2008-030]
Spectrum analysis is a fundamental tool for diagnostic purposes widely used in monitoring and diagnostic systems. [...]
http://zet10.ipee.pwr.wroc.pl/record/37/files/
Details vom Eintrag - Ähnliche Datensätze

Haben Sie nicht gefunden was Sie suchten? Versuchen Sie Ihre Suche auf anderen Servern:
EMTP in Google Books
EMTP in Google Scholar
EMTP in Google Web
EMTP in INSPEC