1. Modeling of overhead transmission lines with line surge arresters for lightning overvoltages / Jaroszewski, M ; Pospieszna, J ; Ranachowski, P ; Rejmund, F [ENY-ARTICLE-2012-312]
Lightning is one of the most significant source of overvoltages in overhead transmission lines. [...]
http://zet10.ipee.pwr.wroc.pl/record/399/files/
Details vom Eintrag - Ähnliche Datensätze
2. Influence of Partial Discharges on ZnO Varistors / Jaroszewski, M [ENY-ARTICLE-2008-181]
The varistors used in HV overvoltage limiters are constantly exposed to operating voltage and environmental hazards and also to transient hazards associated with, among others, overvoltages or pollution. [...]
http://zet10.ipee.pwr.wroc.pl/record/231/files/
Details vom Eintrag - Ähnliche Datensätze
3. Effect of Voltage Harmonics Content on Arrester Diagnostic Result / Jaroszewski, M ; Kostyla, P ; Wieczorek, K [ENY-ARTICLE-2008-180]
Diagnoses of HV arresters are usually based on an analysis of total leakage current harmonics. [...]
http://zet10.ipee.pwr.wroc.pl/record/230/files/
Details vom Eintrag - Ähnliche Datensätze
4. Changes in varistors properties after radial field test / Jaroszewski, M ; Korycki, P ; Wieczorek, K ; Zakrzewski, J [ENY-ARTICLE-2008-179]
ZnO varistors are used in commercial surge arresters in high voltage application in the area of power engineering. [...]
http://zet10.ipee.pwr.wroc.pl/record/229/files/
Details vom Eintrag - Ähnliche Datensätze
5. Capacitance Changes in Degraded Metal Oxide Varistors / Jaroszewski, M ; Wieczorek, K ; Bretuj, W ; Kostyla, P [ENY-ARTICLE-2008-178]
ZnO based ceramics show a highly nonlinear current-voltage (I-V) characteristic due to intergranular layers at the boundaries of ZnO grains. [...]
http://zet10.ipee.pwr.wroc.pl/record/228/files/
Details vom Eintrag - Ähnliche Datensätze
6. Analyzing of varistor model response for sinusoidal signal with harmonics / Jaroszewski, M [ENY-ARTICLE-2008-125]
In this paper the effect of harmonics content in the voltage signal on the varistor model response is analysed using Matlab computer simulations. [...]
http://zet10.ipee.pwr.wroc.pl/record/163/files/
Details vom Eintrag - Ähnliche Datensätze
7. Methods of Determining Internal Parameters of Varistor Model / Jaroszewski, M ; Kostyla, P [ENY-ARTICLE-2008-122]
ZnO varistors are semiconductor devices with highly nonlinear current-voltage characteristic and are widely used as devices for overvoltage protection. [...]
http://zet10.ipee.pwr.wroc.pl/record/160/files/
Details vom Eintrag - Ähnliche Datensätze
8. Metoda określenia wartości parametrów wewnętrznych modelu warystora na podstawie pomiaru wartości chwilowych prądu i napięcia / Jaroszewski, M ; Kostyla, P ; Waclawek, Z [I07/2007/I-058] [ENY-ARTICLE-2008-113]
Beziskiernikowe ograniczniki przepięć, których aktywną część stanowią warystory oparte na tlenku cynku, spełniają coraz powszechniej rolę układów ochrony izolacji urządzeń elektroenergetycznych. [...]
http://zet10.ipee.pwr.wroc.pl/record/142/files/
Details vom Eintrag - Ähnliche Datensätze
9. Wpływ udarów prądowych na zjawiska starzeniowe w ceramice warystorowej. / Jaroszewski, M ; Pospieszna, J [I07/2007/I-059] [ENY-ARTICLE-2008-112]
W artykule przedstawiono wpływ impulsów prądowych na właściwości elektryczne warystorów ZnO. [...]
http://zet10.ipee.pwr.wroc.pl/record/141/files/
Details vom Eintrag - Ähnliche Datensätze