1.
| Franklin rods - sharp or blunt ?
/ Chrzan, K L
[ENY-ARTICLE-2013-348]
This paper gives the historical background of 250 year old question: should the Franklin rod tip be sharp or blunt ? The earlier works, the new field results from USA and own laboratory experiments are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/435/files/
Detailed record - Similar records |
2.
| Application of lightning location systems for fault detection on transmission and distribution lines
/ Chrzan, K L ; Bodzak, P ; Gajda, W
[ENY-ARTICLE-2012-326]
The lightning location systems were installed in many countries during last twenty years. [...]
http://zet10.ipee.pwr.wroc.pl/record/413/files/
Detailed record - Similar records |
3.
| PSPICE appliction for modelling of cap and pin insulator strings
/ Chrzan, K L ; Rebizant, W
[ENY-ARTICLE-2012-318]
The use of PSPICE program in HV engineering is shown. [...]
http://zet10.ipee.pwr.wroc.pl/record/405/files/
Detailed record - Similar records |
4.
| History of lightning protection in Poland
/ Chrzan, K L ; Marciniak, R
[ENY-ARTICLE-2012-316]
The history of lightning protection in Poland and its short overview in the world is given. [...]
http://zet10.ipee.pwr.wroc.pl/record/403/files/
Detailed record - Similar records |
5.
| History of lightning protection in Poland
/ Chrzan, K L ; Marciniak, R
[ENY-ARTICLE-2012-315]
The history of lightning protection in Poland and its short overview in the world is given. [...]
http://zet10.ipee.pwr.wroc.pl/record/402/files/
Detailed record - Similar records |
6.
| Inefficacité des Paratonnerres à Avance d’Amorçage
/ Chrzan, K L ; Teguar, M
[ENY-ARTICLE-2012-314]
Tests on three early streamer emission (ESE) terminals, manufactured by different firms, were carried out. [...]
http://zet10.ipee.pwr.wroc.pl/record/401/files/
Detailed record - Similar records |
7.
| Výzkumy na jímačích ESE
/ Chrzan, K L
[ENY-ARTICLE-2012-313]
The paper reviews about research of radioactive lightning rods carried out 30 years ago and about new measurements of early streamer emission terminals. [...]
http://zet10.ipee.pwr.wroc.pl/record/400/files/
Detailed record - Similar records |
8.
| Modeling of overhead transmission lines with line surge arresters for lightning overvoltages
/ Jaroszewski, M ; Pospieszna, J ; Ranachowski, P ; Rejmund, F
[ENY-ARTICLE-2012-312]
Lightning is one of the most significant source of overvoltages in overhead transmission lines. [...]
http://zet10.ipee.pwr.wroc.pl/record/399/files/
Detailed record - Similar records |
9.
| Effect of impulse polarity on the flashover voltage of polluted cap and pin insulators
/ Chrzan, K L ; Schwarz, H ; Haeusler, H
[ISBN 978-0-620-44584-9]
[ENY-ARTICLE-2009-278]
The lightning impulse flashover voltage on clean and polluted cap and pin insulators under high humidity conditions were measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/346/files/
Detailed record - Similar records |
10.
| Lightning impulse performance of polluted medium voltage insulators
/ Chrzan, K L
[ISBN 978-0-620-44584-9]
[ENY-ARTICLE-2009-277]
The concentrated dry bands on many silicone rubber insulators and also on porcelain insulators were observed by means of termovision camera. [...]
http://zet10.ipee.pwr.wroc.pl/record/345/files/
Detailed record - Similar records |