Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 9 rekordów  Szukanie trwało 0.03 sekund. 
1. Influence of profile on the pollution performance of ceramic long-rod insulators / Chrzan, K L [ENY-ARTICLE-2013-349]
The long rod insulators with different profiles were shown. [...]
http://zet10.ipee.pwr.wroc.pl/record/436/files/
Rekord szczegółowy - Podobne rekordy
2. Pollution flashover of single unit metal oxide arresters / Chrzan, K L ; Koehler, W. [ENY-ARTICLE-2013-342]
Flashover voltage of uniform and non-uniform polluted metal oxide arresters and their porcelain housings without internal parts was measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/429/files/
Rekord szczegółowy - Podobne rekordy
3. Thermische Eigenshaften von Fremdschichten / Chrzan, K L ; Koehler, W [ENY-ARTICLE-2012-317]
In the paper the conductive behavior of saturated and unsaturated electrolytic solutions as a function of temperature is discussed. [...]
http://zet10.ipee.pwr.wroc.pl/record/404/files/
Rekord szczegółowy - Podobne rekordy
4. Leakage Current on Porcelain and Silicone Insulators Under Sea or Light Industrial Pollution / Chrzan, K L ; Vosloo, W L ; Holtzhausen, J P [ENY-ARTICLE-2012-309]
Abstract—The leakage current on heavily polluted silicone rubber insulators is usually smaller than on similarly polluted porcelain insulators. [...]
http://zet10.ipee.pwr.wroc.pl/record/396/files/
Rekord szczegółowy - Podobne rekordy
5. Leakage currents on naturally contaminated porcelain and silicone insulators. / Chrzan, K L [ENY-ARTICLE-2012-308]
The leakage current measurements on standard post insulators and on rod insulators without sheds were carried out. [...]
http://zet10.ipee.pwr.wroc.pl/record/395/files/
Rekord szczegółowy - Podobne rekordy
6. Effect of impulse polarity on the flashover voltage of polluted cap and pin insulators / Chrzan, K L ; Schwarz, H ; Haeusler, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-278]
The lightning impulse flashover voltage on clean and polluted cap and pin insulators under high humidity conditions were measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/346/files/
Rekord szczegółowy - Podobne rekordy
7. Silicone rubber insulators with notched surface / Chrzan, K L [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-276]
A modification of an insulator profile was proposed and the advantage of a new solution was shown. [...]
http://zet10.ipee.pwr.wroc.pl/record/344/files/
Rekord szczegółowy - Podobne rekordy
8. Behaviour of Insulators and Surge Arresters at Glogow Pollution Test Station / Chrzan, K L ; Haddad, A [I07/2005/I-005] [ENY-ARTICLE-2008-222]
The paper reports on the pollution performance of different insulators and surge arresters at Glogow test station from 1981 up to 2004. [...]
http://zet10.ipee.pwr.wroc.pl/record/277/files/
Rekord szczegółowy - Podobne rekordy
9. Performance of Composite Insulators Without Sheds under Light Pollution / Chrzan, K L [ENY-ARTICLE-2008-221]
The test of insulators without sheds or with small sheds number at Glogow pollution station was described. [...]
http://zet10.ipee.pwr.wroc.pl/record/276/files/
Rekord szczegółowy - Podobne rekordy

Jeżeli nie znaleziono tego czego szukasz, spróbuj szukać na innych serwerach:
pollution flashover w Google Books
pollution flashover w Google Scholar
pollution flashover w Google Web
pollution flashover w INSPEC