61. Electrical Strength of Air Containing Ozone and Nitric Oxides Produced by Intensive Partial Discharges / Chrzan, K L ; Andino, J M [ENY-ARTICLE-2008-217]
Internal arcing test results of gapped Sic arresters are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/271/files/
Details vom Eintrag - Ähnliche Datensätze
62. Pollution Performance of 110 kV Metal Oxide Arresters / Chrzan, K L ; Pohl, Z ; Grzybowski, S ; Kohler, W [ENY-ARTICLE-2008-216]
Pollution test results of single unit 110 kV metal oxide surge arresters with porcelain housing according to the solid layer and salt fog methods are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/270/files/
Details vom Eintrag - Ähnliche Datensätze
63. Pollution test station Glogow, twenty years of research / Chrzan, K L [ENY-ARTICLE-2008-215]
The evaluation of electrical stress of polluted outdoor insulators was carried out at the field test station located at a copper smelting plant Głogów in 1987 and 2002. [...]
http://zet10.ipee.pwr.wroc.pl/record/269/files/
Details vom Eintrag - Ähnliche Datensätze
64. Behaviour of Zinc Oxide Surge Arresters Under Pollution / Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L [ENY-ARTICLE-2008-214]
This paper presents results of pollution tests with A. [...]
http://zet10.ipee.pwr.wroc.pl/record/268/files/
Details vom Eintrag - Ähnliche Datensätze
65. Behaviour of zinc oxide surge arresters under pollution / Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L [I07/1990/I-114] [ENY-ARTICLE-2008-213]
This paper presents results of pollution tests with AC voltages which were carried out with a multi-unit zinc oxide arrester. [...]
http://zet10.ipee.pwr.wroc.pl/record/267/files/
Details vom Eintrag - Ähnliche Datensätze
66. Inefficacy of radioactive terminals and early streamer emission terminals / Chrzan, K L ; Hartono, Z A [I07/2003/I-035] [ENY-ARTICLE-2008-211]
The paper reviews about research of radioactive lightning rods carried out 30 years ago and about new measurements of early streamer emission terminals. [...]
http://zet10.ipee.pwr.wroc.pl/record/265/files/
Details vom Eintrag - Ähnliche Datensätze
67. Fuzzy Set Approach to Transformer Differential Relay / Wiszniewski, A ; Kasztenny, B [ISBN: 0-85296-559-1] [ENY-ARTICLE-2008-210]
In the process of decision making by a transformer differential relay often occurs a measure of uncertainty. [...]
http://zet10.ipee.pwr.wroc.pl/record/264/files/
Details vom Eintrag - Ähnliche Datensätze
68. Real-Time Modelling and Digital Implementation of Fuzzy-Logic Controllers / Kasztenny, B ; Hatziadoniu, C ; Wiszniewski, A [ENY-ARTICLE-2008-209]
This paper is concerned with the numerical optimization of the Fuzzy Logic Controller (FLC) for both its efficient simulation and easy real-time implementation. [...]
http://zet10.ipee.pwr.wroc.pl/record/263/files/
Details vom Eintrag - Ähnliche Datensätze
69. Probes for spot measurement of surface conductivity on polluted insulators / Chrzan, K L ; Farzaneh, M [I07/2006/I-016] [ENY-ARTICLE-2008-207]
The surface conductivity of insulators in the field is usually very non-uniformly distributed. [...]
http://zet10.ipee.pwr.wroc.pl/record/261/files/
Details vom Eintrag - Ähnliche Datensätze
70. Distance Digital Algorithm Immune to Saturation of Current Transformer / Wiszniewski, A ; Szafran, J [I08/1989/I-044] [ENY-ARTICLE-2008-206]
Saturation of current transformers due to slowly decaying primary current D. [...]
http://zet10.ipee.pwr.wroc.pl/record/260/files/
Details vom Eintrag - Ähnliche Datensätze