Elektrotechnik TU Wroclaw

Elektrotechnik TU Wroclaw 292 Datensätze gefunden  Anfangvorherige169 - 178nächsteEnde  gehen zum Datensatz: Die Suche hat 0.03 Sekunden gedauert. 
169. Simulative Analysis of a New Type Wide Range Estimator of Protection Criterion Values / Szafran, J ; Rebizant, W ; Michalik, M [I08/1998/I-119] [ENY-ARTICLE-2008-160]
In the paper a new adaptive estimator of protection criterion values insensitive to wide range power system frequency changes is proposed and analysed. [...]
http://zet10.ipee.pwr.wroc.pl/record/207/files/
Details vom Eintrag - Ähnliche Datensätze
170. Efficient Frequency-Adaptive Amplitude Tracking Algorithms for Protection Purposes / Rebizant, W ; Rusek, B [I08/2003/I-091] [ENY-ARTICLE-2008-159]
The new, fast and adaptive algorithms for measurement of signal amplitude for protection and control purposes are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/206/files/
Details vom Eintrag - Ähnliche Datensätze
171. Asynchronous Generator Behavior After a Sudden Load Rejection / Rebizant, W ; Terzija, V [I08/2003/I-092] [ENY-ARTICLE-2008-158]
In the paper load rejection test, performed at a hydro power plant in Sweden, equipped with asynchronous generators, is described and analysed from the electromechanical transient processes and signal distortions points of view. [...]
http://zet10.ipee.pwr.wroc.pl/record/205/files/
Details vom Eintrag - Ähnliche Datensätze
172. Accurate Location of Faults on Three-Terminal Line with Use of Three-End Unsynchronised Measurements / Izykowski, J ; Rosolowski, E ; Molag, R ; Balcerek, P ; et al [ENY-ARTICLE-2008-157]
This paper presents a new fault location algorithm for three-terminal line utilising unsynchronised measurements of three-end currents and voltages. [...]
http://zet10.ipee.pwr.wroc.pl/record/204/files/
Details vom Eintrag - Ähnliche Datensätze
173. A New Fault Location Algorithm for Use with Current Differential Protective Relays of Two-Terminal Line / Izykowski, J ; Rosolowski, E ; Saha, M [ENY-ARTICLE-2008-156]
A new fault location algorithm utilising synchronised measurements of two-end currents and one-end voltage is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/203/files/
Details vom Eintrag - Ähnliche Datensätze
174. Wavelets and Prony Method for Disturbance Detection in Wind Farms / Lobos, T ; Rezmer, J ; Janik, P ; Amaris, H ; et al [ENY-ARTICLE-2008-155]
Wind generator impact on power quality is crucial for power system operation. [...]
http://zet10.ipee.pwr.wroc.pl/record/202/files/
Details vom Eintrag - Ähnliche Datensätze
175. Advanced Signal Processing Methods for Evaluation of Harmonic Distortion Caused by DFIG Wind Generator / Janik, P ; Leonowicz, Z ; Rezmer, J ; Schostan, S ; et al [ENY-ARTICLE-2008-154]
Intensified growth of wind power generation emphasizes the need for detailed evaluation of disturbances caused by wind generators. [...]
http://zet10.ipee.pwr.wroc.pl/record/201/files/
Details vom Eintrag - Ähnliche Datensätze
176. Statistics of Short-Circuit Signals for Power System Protection Purposes / Rebizant, W ; Szafran, J ; Feser, K ; Oechsle, F [I08/2000/I-134] [ENY-ARTICLE-2008-153]
Basic ideas of probability and statistics with application to chosen power system protection problems are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/195/files/
Details vom Eintrag - Ähnliche Datensätze
177. ANN-based Detection of OS Conditions in Power System / Rebizant, W [I08/2000/I-133] [ENY-ARTICLE-2008-152]
In the paper a new neural network based out-of-step protection scheme is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/194/files/
Details vom Eintrag - Ähnliche Datensätze
178. Real-time Implementation of Adaptive Amplitude Estimators for Protection and Control Purposes. / Rebizant, W ; Staszewski, J ; Lee, S J ; Kang, S H [I08/2003/I-067] [ENY-ARTICLE-2008-151]
In the paper a new fast and adaptive scheme for measurement of signal amplitude for protection and control purposes is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/193/files/
Details vom Eintrag - Ähnliche Datensätze

Elektrotechnik TU Wroclaw : 292 Datensätze gefunden   Anfangvorherige169 - 178nächsteEnde  gehen zum Datensatz:
Haben Sie nicht gefunden was Sie suchten? Versuchen Sie Ihre Suche auf anderen Servern:
wroclaw in Google Books
wroclaw in Google Scholar
wroclaw in Google Web
wroclaw in INSPEC