Elektrotechnik TU Wroclaw

Elektrotechnik TU Wroclaw 192 Datensätze gefunden  1 - 25nächsteEnde  gehen zum Datensatz: Die Suche hat 0.02 Sekunden gedauert. 
1. Analysis of SDFT based phase detection system for grid synchronization of distributed generation systems / Chitti Babu, B ; Sridharan, K ; Rosolowski, E ; Leonowicz, Z [http://dx.doi.org/10.1016/j.jestch.2014.07.005] [ENY-PREPRINT-2014-015]
A fast and exact detection of phase and fundamental frequency of grid voltage/current is essential for calculating accurate reference signal in order to implement the control algorithm of inverter-interfaced distributed generation (DG) system and realize precise harmonic compensation. [...]
http://zet10.ipee.pwr.wroc.pl/record/455/files/
Details vom Eintrag - Ähnliche Datensätze
2. Determining of Fault Locations with Hilbert – Huang Transformation on XLPE Cables between Land and Offshore Substations / Bernadić, A ; Leonowicz, Z [ENY-ARTICLE-2014-362]
Using of mathematical transformations and digital signal processing (DSP) methods of recorded voltage and currents in power systems in order to extract important informations about physical processes is already known. [...]
http://zet10.ipee.pwr.wroc.pl/record/453/files/
Details vom Eintrag - Ähnliche Datensätze
3. Wide-area system of registration and processing of power quality data in power grid with distributed generation Part I. System description, functional tests and synchronous recordings Part II. Localization and tracking of the sources of disturbances / Leonowicz, Z ; Rezmer, J ; Sikorski, T ; Szymanda, J ; et al [ENY-ARTICLE-2014-361]
This paper presents the developed and built comprehensive system of registration, archiving and data processing for the wide-area monitoring of power quality in a separated part of real power grid with distributed renewable generation. [...]
http://zet10.ipee.pwr.wroc.pl/record/452/files/
Details vom Eintrag - Ähnliche Datensätze
4. Error Compensation in Distance Relays Caused by Wind Power Plants in the Power Grid / Trujillo, L ; Conde, A ; Leonowicz, Z [http://www.sciencedirect.com/science/article/pii/S0378779613002198] [ENY-PREPRINT-2013-013]
This article presents the Prony method as a filtering technique for distance relays. [...]
http://zet10.ipee.pwr.wroc.pl/record/442/files/
Details vom Eintrag - Ähnliche Datensätze
5. Application of the Prony Method for Compensation of Errors in Distance Relays / Trujillo, L ; Conde, A ; Leonowicz, Z [doi: 10.1109/EEEIC.2013.6549580 ] [ENY-ARTICLE-2013-352]
In this paper we propose an application of the Prony method as a filtering technique for distance relays. [...]
http://zet10.ipee.pwr.wroc.pl/record/440/files/
Details vom Eintrag - Ähnliche Datensätze
6. Fault Location in Power Networks with Mixed Feeders using the Complex Space-Phasor and Hilbert-Huang Transform / Bernadić, A ; Leonowicz, Z [http://dx.doi.org/10.1016/j.ijepes.2012.04.012] [ENY-ARTICLE-2012-339]
The paper introduces a practical approach to power system fault location in power networks using advanced fault signal processing. [...]
http://zet10.ipee.pwr.wroc.pl/record/426/files/
Details vom Eintrag - Ähnliche Datensätze
7. Condition Monitoring & Fault Diagnosis System for Offshore Wind Turbines / Ouadie, B ; Heraud, N ; Leonowicz, Z [Digital Object Identifier: 10.1109/EEEIC.2012.6221389] [ENY-ARTICLE-2012-338]
Due to the technological development, the electronic power progress and economic stake, through the use of Wound Rotor Induction Motor (WRIM) has taken more and more places in different domains (transport, energy production, electric drive. [...]
http://zet10.ipee.pwr.wroc.pl/record/425/files/
Details vom Eintrag - Ähnliche Datensätze
8. Intelligent wireless street lighting system / Leccese, F ; Leonowicz, Z [Digital Object Identifier: 10.1109/EEEIC.2012.6221515] [ENY-ARTICLE-2012-337]
We propose an innovative wireless street lighting system with optimized management and efficiency. [...]
http://zet10.ipee.pwr.wroc.pl/record/424/files/
Details vom Eintrag - Ähnliche Datensätze
9. Impact of Characteristics of Block-Transformers on Inrush Currents and Voltage Distortions at the Connection Point of Wind Parks / Bernadić, A ; Brnadić, I ; Leonowicz, Z [Digital Object Identifier: 10.1109/EEEIC.2012.6221522] [ENY-ARTICLE-2012-335]
In the procedure of connecting large wind parks (WP) to the external power grid, TSO's or DSO's request is that WPs in operation do not excessively affect the power quality in the connection point. [...]
http://zet10.ipee.pwr.wroc.pl/record/422/files/
Details vom Eintrag - Ähnliche Datensätze
10. Power line fault location using the Complex Space-Phasor and Hilbert-Huang Transform / Bernadić, A ; Leonowicz, Z [I07/2011/I-024] [ENY-PREPRINT-2011-012]
Fault location finding in power system is very important problem in power system monitoring. [...]
http://zet10.ipee.pwr.wroc.pl/record/374/files/
Details vom Eintrag - Ähnliche Datensätze
11. New Digital Algorithms for On-line Determination of Symmetrical Components in Power Systems / Lobos, T ; Schneider, E [ENY-ARTICLE-2010-293]
Using the Fourier method the Kalman theory and the Walsh functions, non-recursive algorithms for the on-line determination of the basic waveforms of the symmetrical components in three-phase power systems are introduced, investigated and compared. [...]
http://zet10.ipee.pwr.wroc.pl/record/366/files/
Details vom Eintrag - Ähnliche Datensätze
12. Comparison between DFT, Adaptive Window DFT and EDFT for Power Quality Frequency Spectrum Analysis / Grossoni, M ; Giarnetti, S ; Leccese, F ; Leonowicz, Z [DOI: 10.13140/2.1.3741.1849] [ENY-ARTICLE-2010-292]
Spectral leakage and picket-fence effects associated with the system fundamental frequency variation and improperly selected sampling time window prevents a direct application of the DFT algorithm with a constant sampling rate. [...]
http://zet10.ipee.pwr.wroc.pl/record/364/files/
Details vom Eintrag - Ähnliche Datensätze
13. Wavelets and Hilbert Transform for detection of short disturbances in electrical power networks / Caciotta, M ; Giarnetti, S ; Leccese, F ; Leonowicz, Z [ENY-ARTICLE-2010-287]
In electrical energy power network, disturbances can cause problems in electronic devices therefore their monitoring is fundamental to properly design the protection and compensation devices. [...]
http://zet10.ipee.pwr.wroc.pl/record/357/files/
Details vom Eintrag - Ähnliche Datensätze
14. Inclined plane test, influence of transformer power / Chrzan, K L [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-281]
The inclined plane method is one of a few other tests that prove the material resistance to erosion and tracking caused by surface discharges. [...]
http://zet10.ipee.pwr.wroc.pl/record/349/files/
Details vom Eintrag - Ähnliche Datensätze
15. Hygroscopic properties of natural pollutants on silicone rubber surfaces / Chrzan, K L ; Greyling, C [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-280]
The aim of this research is to determine whether hydrophilic and hygroscopic particulate pollutants on glass and silicone insulator surfaces maintain their electrical and water absorption properties, once low molecular weight siloxanes have migrated through the pollution layer. [...]
http://zet10.ipee.pwr.wroc.pl/record/348/files/
Details vom Eintrag - Ähnliche Datensätze
16. Artificial rain test of outdoor long rod insulators / Chrzan, K L ; Streubel, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-279]
Due to the decrease of industrial contamination emission nearly the whole territory of Poland belongs to the pollution class light. [...]
http://zet10.ipee.pwr.wroc.pl/record/347/files/
Details vom Eintrag - Ähnliche Datensätze
17. Effect of impulse polarity on the flashover voltage of polluted cap and pin insulators / Chrzan, K L ; Schwarz, H ; Haeusler, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-278]
The lightning impulse flashover voltage on clean and polluted cap and pin insulators under high humidity conditions were measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/346/files/
Details vom Eintrag - Ähnliche Datensätze
18. Time-varying signal parameters for assessment of disturbances in wind energy systems / Lobos, T ; Schegner, P ; Sikorski, T [ENY-ARTICLE-2009-270]
This paper proposes some extended method for assessment of transient disturbances in wind energy systems. [...]
http://zet10.ipee.pwr.wroc.pl/record/338/files/
Details vom Eintrag - Ähnliche Datensätze
19. Detection of Short Transients and Interruptions using the Hilbert Transform / Caciotta, M ; Giarnetti, S ; Leccese, F ; Leonowicz, Z [ENY-ARTICLE-2009-269]
In electrical energy power networks, disturbances can cause problems in electronic devices so their monitoring is fundamental in Power Quality. [...]
http://zet10.ipee.pwr.wroc.pl/record/337/files/
Details vom Eintrag - Ähnliche Datensätze
20. Power Quality in Wind Power Systems / Leonowicz, Z [ENY-ARTICLE-2009-268]
Wind power generation systems influence power quality in a specific way making important the need for detailed and accurate evaluation of disturbances caused by wind generators. [...]
http://zet10.ipee.pwr.wroc.pl/record/336/files/
Details vom Eintrag - Ähnliche Datensätze
21. Nonlinear regression applied for power quality disturbances characterization in grids with wind generators / Janik, P ; Lobos, T ; Rezmer, J ; Waclawek, Z [I07/2009/I-035] [ENY-ARTICLE-2009-267]
The impact of wind generation on the electrical system should be assessed to figure out potential hazards to system operation and deterioration of power quality indices. [...]
http://zet10.ipee.pwr.wroc.pl/record/335/files/
Details vom Eintrag - Ähnliche Datensätze
22. Adaptation of SVD and Prony method for precise computation of current components in networks with wind generation. / Janik, P ; Rezmer, J ; Ruczewski, P ; Waclawek, Z ; et al [I07/2009/I-037] [ENY-ARTICLE-2009-266]
Precise computation of current components is a key prerequisite for reliable assessment of power quality. [...]
http://zet10.ipee.pwr.wroc.pl/record/334/files/
Details vom Eintrag - Ähnliche Datensätze
23. Assessment of transient disturbances in HV systems with single-phase autoreclosures / Lobos, T ; Schegner, P ; Sikorski, T [ENY-ARTICLE-2009-265]
This paper proposes some extended method for assessment of transient disturbances in HV system with single-phase autoreclosures. [...]
http://zet10.ipee.pwr.wroc.pl/record/333/files/
Details vom Eintrag - Ähnliche Datensätze
24. Computation of Voltage Sag Initiation with Fourier based Algorithm, Kalman Filter and Wavelets / Amaris, H ; Alvarez, A ; Florez, D ; Lobos, T ; et al [ENY-ARTICLE-2009-264]
Dynamic Voltage Restorers (DVR) have been successfully applied for voltage dip mitigation in the last years. [...]
http://zet10.ipee.pwr.wroc.pl/record/332/files/
Details vom Eintrag - Ähnliche Datensätze
25. Computation of Spectral Components in System with Wind Generation Unit / Janik, P ; Lobos, T ; Rezmer, J ; Schegner, P ; et al [ENY-ARTICLE-2009-263]
Signal parameters estimation is an important prerequisite for assessment of power quality (PQ) indices. [...]
http://zet10.ipee.pwr.wroc.pl/record/331/files/
Details vom Eintrag - Ähnliche Datensätze

Elektrotechnik TU Wroclaw : 192 Datensätze gefunden   1 - 25nächsteEnde  gehen zum Datensatz:
Haben Sie nicht gefunden was Sie suchten? Versuchen Sie Ihre Suche auf anderen Servern:
poland in Google Books
poland in Google Scholar
poland in Google Web
poland in INSPEC