Elektrotechnik TU Wroclaw

Elektrotechnik TU Wroclaw 16 Datensätze gefunden  1 - 10nächste  gehen zum Datensatz: Die Suche hat 0.01 Sekunden gedauert. 
1.
Prediction of CT saturation period for differential relay adaptation purposes / Rebizant, W ; Hayder, T ; Schiel, L [ENY-ARTICLE-2008-147]
A new approach to CT saturation assessment is presented in the paper. [...]
http://zet10.ipee.pwr.wroc.pl/record/186/files/
Details vom Eintrag - Ähnliche Datensätze
2.
CT saturation correction based on the estimated CT saturation time constant / Rebizant, W ; Wiszniewski, A ; Schiel, L [I08/2008/I-021] [ENY-ARTICLE-2008-203]
A new method for CT saturation correction is presented that is based on an on-line estimation of the CT magnetizing inductance. [...]
http://zet10.ipee.pwr.wroc.pl/record/257/files/
Details vom Eintrag - Ähnliche Datensätze
3.
Correction of Current Transformer Transient Performance / Wiszniewski, A ; Rebizant, W ; Schiel, L [ENY-ARTICLE-2008-202]
If a current transformer (CT) saturates while transforming the heavy primary current, in each period, there are sections when the magnetic core is unsaturated and transformation is correct, and when it is saturated, it causes enormous errors. [...]
http://zet10.ipee.pwr.wroc.pl/record/256/files/
Details vom Eintrag - Ähnliche Datensätze
4.
Distance Digital Algorithm Immune to Saturation of Current Transformer / Wiszniewski, A ; Szafran, J [I08/1989/I-044] [ENY-ARTICLE-2008-206]
Saturation of current transformers due to slowly decaying primary current D. [...]
http://zet10.ipee.pwr.wroc.pl/record/260/files/
Details vom Eintrag - Ähnliche Datensätze
5.
Fuzzy Set Approach to Transformer Differential Relay / Wiszniewski, A ; Kasztenny, B [ISBN: 0-85296-559-1] [ENY-ARTICLE-2008-210]
In the process of decision making by a transformer differential relay often occurs a measure of uncertainty. [...]
http://zet10.ipee.pwr.wroc.pl/record/264/files/
Details vom Eintrag - Ähnliche Datensätze
6.
A multi-criteria differential transformer relay based on fuzzy logic / Wiszniewski, A ; Kasztenny, B [ENY-ARTICLE-2008-197]
This paper presents a digital relay scheme for the primary protection of power transformers. [...]
http://zet10.ipee.pwr.wroc.pl/record/251/files/
Details vom Eintrag - Ähnliche Datensätze
7.
Statistics of Short-Circuit Signals for Power System Protection Purposes / Rebizant, W ; Szafran, J ; Feser, K ; Oechsle, F [I08/2000/I-134] [ENY-ARTICLE-2008-153]
Basic ideas of probability and statistics with application to chosen power system protection problems are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/195/files/
Details vom Eintrag - Ähnliche Datensätze
8.
Adaptation of SVD and Prony method for precise computation of current components in networks with wind generation. / Janik, P ; Rezmer, J ; Ruczewski, P ; Waclawek, Z ; et al [I07/2009/I-037] [ENY-ARTICLE-2009-266]
Precise computation of current components is a key prerequisite for reliable assessment of power quality. [...]
http://zet10.ipee.pwr.wroc.pl/record/334/files/
Details vom Eintrag - Ähnliche Datensätze
9.
Adaptive estimation of wide range frequency changes for power generator protection and control purposes / Szafran, J ; Rebizant, W ; Michalik, M [I08/1999/I-015] [ENY-ARTICLE-2008-150]
A method and a detailed adaptive algorithm for wide-range frequency change measurement is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/192/files/
Details vom Eintrag - Ähnliche Datensätze
10.
Current Transformer Saturation Detection with Genetically Optimized Neural Networks / Rebizant, W ; Bejmert, D [ENY-ARTICLE-2008-146]
Application of the genetic algorithm (GA) for optimization of artificial neural network (ANN) based CT saturation detector is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/185/files/
Details vom Eintrag - Ähnliche Datensätze

Haben Sie nicht gefunden was Sie suchten? Versuchen Sie Ihre Suche auf anderen Servern:
recid:186 in Google Books
recid:186 in Google Scholar
recid:186 in Google Web
recid:186 in INSPEC