Elektrotechnik TU Wroclaw

Elektrotechnik TU Wroclaw 9 Datensätze gefunden  Die Suche hat 0.00 Sekunden gedauert. 
1.
Correction of Current Transformer Transient Performance / Wiszniewski, A ; Rebizant, W ; Schiel, L [ENY-ARTICLE-2008-202]
If a current transformer (CT) saturates while transforming the heavy primary current, in each period, there are sections when the magnetic core is unsaturated and transformation is correct, and when it is saturated, it causes enormous errors. [...]
http://zet10.ipee.pwr.wroc.pl/record/256/files/
Details vom Eintrag - Ähnliche Datensätze
2.
CT saturation correction based on the estimated CT saturation time constant / Rebizant, W ; Wiszniewski, A ; Schiel, L [I08/2008/I-021] [ENY-ARTICLE-2008-203]
A new method for CT saturation correction is presented that is based on an on-line estimation of the CT magnetizing inductance. [...]
http://zet10.ipee.pwr.wroc.pl/record/257/files/
Details vom Eintrag - Ähnliche Datensätze
3.
Distance Digital Algorithm Immune to Saturation of Current Transformer / Wiszniewski, A ; Szafran, J [I08/1989/I-044] [ENY-ARTICLE-2008-206]
Saturation of current transformers due to slowly decaying primary current D. [...]
http://zet10.ipee.pwr.wroc.pl/record/260/files/
Details vom Eintrag - Ähnliche Datensätze
4.
Current Transformer Saturation Detection with Genetically Optimized Neural Networks / Rebizant, W ; Bejmert, D [ENY-ARTICLE-2008-146]
Application of the genetic algorithm (GA) for optimization of artificial neural network (ANN) based CT saturation detector is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/185/files/
Details vom Eintrag - Ähnliche Datensätze
5.
Calculation of Current Transformer Transient Errors / Wiszniewski, A [ENY-ARTICLE-2008-205]
Transient saturation of current transformers may cause maloperation of protective devices. [...]
http://zet10.ipee.pwr.wroc.pl/record/259/files/
Details vom Eintrag - Ähnliche Datensätze
6.
Prediction of CT saturation period for differential relay adaptation purposes / Rebizant, W ; Hayder, T ; Schiel, L [ENY-ARTICLE-2008-147]
A new approach to CT saturation assessment is presented in the paper. [...]
http://zet10.ipee.pwr.wroc.pl/record/186/files/
Details vom Eintrag - Ähnliche Datensätze
7.
Real-Time Determination of Power System Frequency / Lobos, T ; Rezmer, J [ENY-ARTICLE-2008-009]
The main frequency is an important parameter of an electrical power system. [...]
http://zet10.ipee.pwr.wroc.pl/record/10/files/
Details vom Eintrag - Ähnliche Datensätze
8.
Fuzzy Set Approach to Transformer Differential Relay / Wiszniewski, A ; Kasztenny, B [ISBN: 0-85296-559-1] [ENY-ARTICLE-2008-210]
In the process of decision making by a transformer differential relay often occurs a measure of uncertainty. [...]
http://zet10.ipee.pwr.wroc.pl/record/264/files/
Details vom Eintrag - Ähnliche Datensätze
9.
Impact of Secondary Burden and X/R Ratio on CT Saturation / Sawko, P [ENY-ARTICLE-2008-141]
Proper selection of a CT (Current Transducer) is required for a good protection scheme operation. [...]
http://zet10.ipee.pwr.wroc.pl/record/179/files/
Details vom Eintrag - Ähnliche Datensätze

Haben Sie nicht gefunden was Sie suchten? Versuchen Sie Ihre Suche auf anderen Servern:
recid:256 in Google Books
recid:256 in Google Scholar
recid:256 in Google Web
recid:256 in INSPEC