Elektrotechnik TU Wroclaw

Elektrotechnik TU Wroclaw 12 Datensätze gefunden  1 - 10nächste  gehen zum Datensatz: Die Suche hat 0.00 Sekunden gedauert. 
1.
Distance Digital Algorithm Immune to Saturation of Current Transformer / Wiszniewski, A ; Szafran, J [I08/1989/I-044] [ENY-ARTICLE-2008-206]
Saturation of current transformers due to slowly decaying primary current D. [...]
http://zet10.ipee.pwr.wroc.pl/record/260/files/
Details vom Eintrag - Ähnliche Datensätze
2.
Correction of Current Transformer Transient Performance / Wiszniewski, A ; Rebizant, W ; Schiel, L [ENY-ARTICLE-2008-202]
If a current transformer (CT) saturates while transforming the heavy primary current, in each period, there are sections when the magnetic core is unsaturated and transformation is correct, and when it is saturated, it causes enormous errors. [...]
http://zet10.ipee.pwr.wroc.pl/record/256/files/
Details vom Eintrag - Ähnliche Datensätze
3.
Application of the Prony Method for Compensation of Errors in Distance Relays / Trujillo, L ; Conde, A ; Leonowicz, Z [doi: 10.1109/EEEIC.2013.6549580 ] [ENY-ARTICLE-2013-352]
In this paper we propose an application of the Prony method as a filtering technique for distance relays. [...]
http://zet10.ipee.pwr.wroc.pl/record/440/files/
Details vom Eintrag - Ähnliche Datensätze
4.
Calculation of Current Transformer Transient Errors / Wiszniewski, A [ENY-ARTICLE-2008-205]
Transient saturation of current transformers may cause maloperation of protective devices. [...]
http://zet10.ipee.pwr.wroc.pl/record/259/files/
Details vom Eintrag - Ähnliche Datensätze
5.
Fuzzy Set Approach to Transformer Differential Relay / Wiszniewski, A ; Kasztenny, B [ISBN: 0-85296-559-1] [ENY-ARTICLE-2008-210]
In the process of decision making by a transformer differential relay often occurs a measure of uncertainty. [...]
http://zet10.ipee.pwr.wroc.pl/record/264/files/
Details vom Eintrag - Ähnliche Datensätze
6.
How to Reduce Errors of Distance Fault Locating Algorithms / Wiszniewski, A [ENY-ARTICLE-2008-198]
Distance fault locating digital algorithms are often based on the processing of fundamental components which are contained in the currents and Voltages. [...]
http://zet10.ipee.pwr.wroc.pl/record/252/files/
Details vom Eintrag - Ähnliche Datensätze
7.
Error Compensation in Distance Relays Caused by Wind Power Plants in the Power Grid / Trujillo, L ; Conde, A ; Leonowicz, Z [http://www.sciencedirect.com/science/article/pii/S0378779613002198] [ENY-PREPRINT-2013-013]
This article presents the Prony method as a filtering technique for distance relays. [...]
http://zet10.ipee.pwr.wroc.pl/record/442/files/
Details vom Eintrag - Ähnliche Datensätze
8.
Prediction of CT saturation period for differential relay adaptation purposes / Rebizant, W ; Hayder, T ; Schiel, L [ENY-ARTICLE-2008-147]
A new approach to CT saturation assessment is presented in the paper. [...]
http://zet10.ipee.pwr.wroc.pl/record/186/files/
Details vom Eintrag - Ähnliche Datensätze
9.
CT saturation correction based on the estimated CT saturation time constant / Rebizant, W ; Wiszniewski, A ; Schiel, L [I08/2008/I-021] [ENY-ARTICLE-2008-203]
A new method for CT saturation correction is presented that is based on an on-line estimation of the CT magnetizing inductance. [...]
http://zet10.ipee.pwr.wroc.pl/record/257/files/
Details vom Eintrag - Ähnliche Datensätze
10.
A multi-criteria differential transformer relay based on fuzzy logic / Wiszniewski, A ; Kasztenny, B [ENY-ARTICLE-2008-197]
This paper presents a digital relay scheme for the primary protection of power transformers. [...]
http://zet10.ipee.pwr.wroc.pl/record/251/files/
Details vom Eintrag - Ähnliche Datensätze

Haben Sie nicht gefunden was Sie suchten? Versuchen Sie Ihre Suche auf anderen Servern:
recid:260 in Google Books
recid:260 in Google Scholar
recid:260 in Google Web
recid:260 in INSPEC