Elektrotechnik TU Wroclaw

Elektrotechnik TU Wroclaw 8 Datensätze gefunden  Die Suche hat 0.00 Sekunden gedauert. 
1.
Performance of Composite Insulators Without Sheds under Light Pollution / Chrzan, K L [ENY-ARTICLE-2008-221]
The test of insulators without sheds or with small sheds number at Glogow pollution station was described. [...]
http://zet10.ipee.pwr.wroc.pl/record/276/files/
Details vom Eintrag - Ähnliche Datensätze
2.
Artificial rain test of outdoor long rod insulators / Chrzan, K L ; Streubel, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-279]
Due to the decrease of industrial contamination emission nearly the whole territory of Poland belongs to the pollution class light. [...]
http://zet10.ipee.pwr.wroc.pl/record/347/files/
Details vom Eintrag - Ähnliche Datensätze
3.
Performance of polymer concrete insulators under light pollution / Chrzan, K L ; Skoczylas, M [I07/2007/I-041] [ENY-ARTICLE-2008-188]
Abstract: This paper deals with polymer concrete, a highly filled composite material as a low cost alternative to porcelain outdoor insulators. [...]
http://zet10.ipee.pwr.wroc.pl/record/239/files/
Details vom Eintrag - Ähnliche Datensätze
4.
Pollution test station Glogow, twenty years of research / Chrzan, K L [ENY-ARTICLE-2008-215]
The evaluation of electrical stress of polluted outdoor insulators was carried out at the field test station located at a copper smelting plant Głogów in 1987 and 2002. [...]
http://zet10.ipee.pwr.wroc.pl/record/269/files/
Details vom Eintrag - Ähnliche Datensätze
5.
Pollution flashover of long rod insulators with different profiles. / Chrzan, K L ; Vokalek, J ; Sklenicka, V ; Petrusch, W ; et al [ENY-ARTICLE-2012-320]
Pollution test of four long rod insulators with different shapes were carried out according to flow on, salt fog and solid layer methods. [...]
http://zet10.ipee.pwr.wroc.pl/record/407/files/
Details vom Eintrag - Ähnliche Datensätze
6.
Influence of High Voltage Insulator on Pollution Flashover Voltage / Wankowicz, J G ; Pohl, Z [ENY-ARTICLE-2009-233]
Results of pollution flashover voltage measurements and optical observation obtained for high voltage insulators placed in the vertical and the horizontal positions are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/292/files/
Details vom Eintrag - Ähnliche Datensätze
7.
Behaviour of Insulators and Surge Arresters at Glogow Pollution Test Station / Chrzan, K L ; Haddad, A [I07/2005/I-005] [ENY-ARTICLE-2008-222]
The paper reports on the pollution performance of different insulators and surge arresters at Glogow test station from 1981 up to 2004. [...]
http://zet10.ipee.pwr.wroc.pl/record/277/files/
Details vom Eintrag - Ähnliche Datensätze
8.
Leakage currents on naturally contaminated porcelain and silicone insulators. / Chrzan, K L [ENY-ARTICLE-2012-308]
The leakage current measurements on standard post insulators and on rod insulators without sheds were carried out. [...]
http://zet10.ipee.pwr.wroc.pl/record/395/files/
Details vom Eintrag - Ähnliche Datensätze