Elektrotechnik TU Wroclaw

Elektrotechnik TU Wroclaw 11 Datensätze gefunden  1 - 10nächste  gehen zum Datensatz: Die Suche hat 0.00 Sekunden gedauert. 
1.
Studies of Epoxy Spacers Subjected to Internal and External Partial Discharge and SF6 Byproducts / Braun, J M ; Chu, F Y ; Tyman, A [ENY-ARTICLE-2008-230]
Ihe reliability of gas insulated switchgear (GIS) has generally been good. [...]
http://zet10.ipee.pwr.wroc.pl/record/285/files/
Details vom Eintrag - Ähnliche Datensätze
2.
Effect of area on surface flashover voltage in vacuum / Cross, J D ; Mazurek, B [ISSN: 0018-9367INSPEC:3152462DOI: 10.1109/14.2330] [ENY-ARTICLE-2008-041]
It is known that the breakdown voltage in a vacuum insulation system drops with an increase in linear dimension of electrodes and with an increase in the number of insulating spacers bridging the gap. [...]
http://zet10.ipee.pwr.wroc.pl/record/49/files/
Details vom Eintrag - Ähnliche Datensätze
3.
The effect of a metallic particle near a spacer on flashover phenomena in SF6. / Mazurek, B ; Cross, J D ; Heeswijk van, R G [I07/1992/P-451] [ENY-ARTICLE-2008-072]
This paper presents a study of the flashover mechanism initiated by metallic particles in SF6 gas. [...]
http://zet10.ipee.pwr.wroc.pl/record/81/files/
Details vom Eintrag - Ähnliche Datensätze
4.
Internal partial discharges test for metal oxide surge arresters / Chrzan, K L [ENY-ARTICLE-2012-327]
Proposals for testing of surge arresters performance under internal partial discharge stress by Sakshaug, Chrzan and Korycki have been presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/414/files/
Details vom Eintrag - Ähnliche Datensätze
5.
Electrical Strength of Air Containing Ozone and Nitric Oxides Produced by Intensive Partial Discharges / Chrzan, K L ; Andino, J M [ENY-ARTICLE-2008-217]
Internal arcing test results of gapped Sic arresters are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/271/files/
Details vom Eintrag - Ähnliche Datensätze
6.
Changes in varistors properties after radial field test / Jaroszewski, M ; Korycki, P ; Wieczorek, K ; Zakrzewski, J [ENY-ARTICLE-2008-179]
ZnO varistors are used in commercial surge arresters in high voltage application in the area of power engineering. [...]
http://zet10.ipee.pwr.wroc.pl/record/229/files/
Details vom Eintrag - Ähnliche Datensätze
7.
Effect of silicone rubber insulators' profiles on their ageing performance in rain conditions / Bretuj, W ; Fleszynski, J ; Tyman, A ; Wieczorek, K [ENY-ARTICLE-2009-236]
Numerous studies have been conducted to understand the effect of insulator profiles on ceramic insulators, whereas for polymer insulators this problem has not sufficiently examined. [...]
http://zet10.ipee.pwr.wroc.pl/record/295/files/
Details vom Eintrag - Ähnliche Datensätze
8.
LONG-TERM STUDY OF CHANGES OF PHYSICO-CHEMICAL PARAMETERS OF TRANSFORMER OILS / Jaroszewski, M ; Pietruszewicz, M [ENY-ARTICLE-2012-329]
The average age of transformers in service is increasing and approaching the end of design life. [...]
http://zet10.ipee.pwr.wroc.pl/record/416/files/
Details vom Eintrag - Ähnliche Datensätze
9.
Influence of moisture and partial discharges on the degradation of high-voltage surge arresters. / Chrzan, K L [ENY-ARTICLE-2012-321]
This paper reports the influence of moisture and internal partial discharges on the degradation of metal oxide varistors in high-voltage surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/408/files/
Details vom Eintrag - Ähnliche Datensätze
10.
Internal Arcing Test on Polluted High Voltage Surge Arresters / Chrzan, K L ; Kohler, W ; Feser, K [ENY-ARTICLE-2009-234]
A test to prove the performance of extremely non-uniform polluted single unit metal oxide (MO) and gapped arresters (SiCA) is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/293/files/
Details vom Eintrag - Ähnliche Datensätze

Haben Sie nicht gefunden was Sie suchten? Versuchen Sie Ihre Suche auf anderen Servern:
recid:285 in Google Books
recid:285 in Google Scholar
recid:285 in Google Web
recid:285 in INSPEC