Electrical Engineering Wroclaw University of Technology

Electrical Engineering Wroclaw University of Technology 100 records found  previous11 - 20nextend  jump to record: Search took 0.01 seconds. 
11. TSC transformer with asymmetric source and load / Mach, V ; Gono, R ; Leonowicz, Z [ENY-ARTICLE-2013-351]
The paper analyses unconventional connection of a three-phase transformer with asymmetric source and load. [...]
http://zet10.ipee.pwr.wroc.pl/record/439/files/
Detailed record - Similar records
12. Fault Location in Power Networks with Mixed Feeders using the Complex Space-Phasor and Hilbert-Huang Transform / Bernadić, A ; Leonowicz, Z [http://dx.doi.org/10.1016/j.ijepes.2012.04.012] [ENY-ARTICLE-2012-339]
The paper introduces a practical approach to power system fault location in power networks using advanced fault signal processing. [...]
http://zet10.ipee.pwr.wroc.pl/record/426/files/
Detailed record - Similar records
13. Condition Monitoring & Fault Diagnosis System for Offshore Wind Turbines / Ouadie, B ; Heraud, N ; Leonowicz, Z [Digital Object Identifier: 10.1109/EEEIC.2012.6221389] [ENY-ARTICLE-2012-338]
Due to the technological development, the electronic power progress and economic stake, through the use of Wound Rotor Induction Motor (WRIM) has taken more and more places in different domains (transport, energy production, electric drive. [...]
http://zet10.ipee.pwr.wroc.pl/record/425/files/
Detailed record - Similar records
14. Intelligent wireless street lighting system / Leccese, F ; Leonowicz, Z [Digital Object Identifier: 10.1109/EEEIC.2012.6221515] [ENY-ARTICLE-2012-337]
We propose an innovative wireless street lighting system with optimized management and efficiency. [...]
http://zet10.ipee.pwr.wroc.pl/record/424/files/
Detailed record - Similar records
15. Assessing the benefits and risks of application of inverter drives in industry / Leonowicz, Z ; Lempart, A [Digital Object Identifier: 10.1109/EEEIC.2012.6221562] [ENY-ARTICLE-2012-336]
This paper presents the impact assessment of converters installed in an industrial plant on the power quality in internal power grid of the plant. [...]
http://zet10.ipee.pwr.wroc.pl/record/423/files/
Detailed record - Similar records
16. Impact of Characteristics of Block-Transformers on Inrush Currents and Voltage Distortions at the Connection Point of Wind Parks / Bernadić, A ; Brnadić, I ; Leonowicz, Z [Digital Object Identifier: 10.1109/EEEIC.2012.6221522] [ENY-ARTICLE-2012-335]
In the procedure of connecting large wind parks (WP) to the external power grid, TSO's or DSO's request is that WPs in operation do not excessively affect the power quality in the connection point. [...]
http://zet10.ipee.pwr.wroc.pl/record/422/files/
Detailed record - Similar records
17. Power line fault location using the Complex Space-Phasor and Hilbert-Huang Transform / Bernadić, A ; Leonowicz, Z [I07/2011/I-024] [ENY-PREPRINT-2011-012]
Fault location finding in power system is very important problem in power system monitoring. [...]
http://zet10.ipee.pwr.wroc.pl/record/374/files/
Detailed record - Similar records
18. Power Quality Report in MV and HV networks / Leonowicz, Z [ENY-REPORT-2010-003]
Example of a power quality report related to generator unit and 110 kV transmission line.
http://zet10.ipee.pwr.wroc.pl/record/372/files/
Detailed record - Similar records
19. Raport o jakości energii / Leonowicz, Z [ENY-REPORT-2010-002]
Przykładowy raport oceny jakości energii w sieci SN 10,5 kV i WN 110 KV.
http://zet10.ipee.pwr.wroc.pl/record/371/files/
Detailed record - Similar records
20. Renewable Energy Sources in Poland / Leonowicz, Z [ENY-TEACHING-2010-037]
Status of RES in Poland in 2010. [...]
http://zet10.ipee.pwr.wroc.pl/record/370/files/
Detailed record - Similar records

Electrical Engineering Wroclaw University of Technology : 100 records found   previous11 - 20nextend  jump to record:
Haven't found what you were looking for? Try your search on other servers:
Leonowicz, Z in Google Books
Leonowicz, Z in Google Scholar
Leonowicz, Z in Google Web
Leonowicz, Z in INSPEC