10. Asynchronous Generator Behavior After a Sudden Load Rejection / Rebizant, W ; Terzija, V [I08/2003/I-092] [ENY-ARTICLE-2008-158]
In the paper load rejection test, performed at a hydro power plant in Sweden, equipped with asynchronous generators, is described and analysed from the electromechanical transient processes and signal distortions points of view. [...]
http://zet10.ipee.pwr.wroc.pl/record/205/files/
Detailed record - Similar records
11. Statistics of Short-Circuit Signals for Power System Protection Purposes / Rebizant, W ; Szafran, J ; Feser, K ; Oechsle, F [I08/2000/I-134] [ENY-ARTICLE-2008-153]
Basic ideas of probability and statistics with application to chosen power system protection problems are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/195/files/
Detailed record - Similar records
12. ANN-based Detection of OS Conditions in Power System / Rebizant, W [I08/2000/I-133] [ENY-ARTICLE-2008-152]
In the paper a new neural network based out-of-step protection scheme is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/194/files/
Detailed record - Similar records
13. Real-time Implementation of Adaptive Amplitude Estimators for Protection and Control Purposes. / Rebizant, W ; Staszewski, J ; Lee, S J ; Kang, S H [I08/2003/I-067] [ENY-ARTICLE-2008-151]
In the paper a new fast and adaptive scheme for measurement of signal amplitude for protection and control purposes is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/193/files/
Detailed record - Similar records
14. Adaptive estimation of wide range frequency changes for power generator protection and control purposes / Szafran, J ; Rebizant, W ; Michalik, M [I08/1999/I-015] [ENY-ARTICLE-2008-150]
A method and a detailed adaptive algorithm for wide-range frequency change measurement is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/192/files/
Detailed record - Similar records
15. Power system frequency estimation / Szafran, J ; Rebizant, W [I08/1998/I-149] [ENY-ARTICLE-2008-149]
A new algorithm of power system frequency estimation is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/191/files/
Detailed record - Similar records
16. Adaptive and intelligent systems for generator monitoring and protection purposes / Rebizant, W ; Szafran, J ; Lee, S J ; Kang, S H [ENY-ARTICLE-2008-148]
New adaptive scheme for signal parameter measurement for generator monitoring and protection is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/187/files/
Detailed record - Similar records
17. Prediction of CT saturation period for differential relay adaptation purposes / Rebizant, W ; Hayder, T ; Schiel, L [ENY-ARTICLE-2008-147]
A new approach to CT saturation assessment is presented in the paper. [...]
http://zet10.ipee.pwr.wroc.pl/record/186/files/
Detailed record - Similar records
18. Current Transformer Saturation Detection with Genetically Optimized Neural Networks / Rebizant, W ; Bejmert, D [ENY-ARTICLE-2008-146]
Application of the genetic algorithm (GA) for optimization of artificial neural network (ANN) based CT saturation detector is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/185/files/
Detailed record - Similar records
19. Wavelet Transform Approach to High Impedance Fault Detection in MV Networks / Michalik, M ; Rebizant, W ; Lukowicz, M ; Lee, S J ; et al [ENY-ARTICLE-2008-145]
Application of wavelet transform technique to high impedance arcing fault detection in distribution networks is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/184/files/
Detailed record - Similar records

Electrical Engineering Wroclaw University of Technology : 19 records found   previous10 - 19  jump to record:
Haven't found what you were looking for? Try your search on other servers:
Rebizant, W in Google Books
Rebizant, W in Google Scholar
Rebizant, W in Google Web