1.
| Analysis of SDFT based phase detection system for grid synchronization of distributed generation systems
/ Chitti Babu, B ; Sridharan, K ; Rosolowski, E ; Leonowicz, Z
[http://dx.doi.org/10.1016/j.jestch.2014.07.005]
[ENY-PREPRINT-2014-015]
A fast and exact detection of phase and fundamental frequency of grid voltage/current is essential for calculating accurate reference signal in order to implement the control algorithm of inverter-interfaced distributed generation (DG) system and realize precise harmonic compensation. [...]
http://zet10.ipee.pwr.wroc.pl/record/455/files/
Detailed record - Similar records |
2.
| Analysis of Recursive DFT Filtering Based Grid Synchronization of Distributed Generation System
/ Chitti Babu, B ; Sridharan, K ; Rosolowski, E ; Leonowicz, Z
[I08/2014/I-069]
[ENY-PREPRINT-2014-014]
A converter-interfaced distributed generation (DG) system, like, wind power system, photovoltaic (PV) and micro-turbine-generator system, requires a fast and exact detection of phase and fundamental frequency of grid current in order to implement the control algorithm of power converters by generating reference currents signals. [...]
http://zet10.ipee.pwr.wroc.pl/record/454/files/
Detailed record - Similar records |
3.
| Komputerowe metody analizy elektromagnetycznych stanów przejściowych. Przykłady.
/ Rosolowski, E
[ENY-TEACHING-2009-033]
Zamieszczone przykłady są uzupełnieniem materiału zawartego w książce Komputerowe metody analizy elektromagnetycznych stanów przejściowych, Oficyna Wydawnicza Politechniki Wrocławskiej, Wrocław 2009. [...]
http://zet10.ipee.pwr.wroc.pl/record/327/files/
Detailed record - Similar records |
4.
| Accurate Location of Faults on Three-Terminal Line with Use of Three-End Unsynchronised Measurements
/ Izykowski, J ; Rosolowski, E ; Molag, R ; Balcerek, P ; et al
[ENY-ARTICLE-2008-157]
This paper presents a new fault location algorithm for three-terminal line utilising unsynchronised measurements of three-end currents and voltages. [...]
http://zet10.ipee.pwr.wroc.pl/record/204/files/
Detailed record - Similar records |
5.
| A New Fault Location Algorithm for Use with Current Differential Protective Relays of Two-Terminal Line
/ Izykowski, J ; Rosolowski, E ; Saha, M
[ENY-ARTICLE-2008-156]
A new fault location algorithm utilising synchronised measurements of two-end currents and one-end voltage is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/203/files/
Detailed record - Similar records |
6.
| New concept for fault location in series-compensated parallel lines
/ Saha, M ; Wikstrom, K ; Izykowski, J ; Rosolowski, E
[I08/2001/I-022]
[ENY-ARTICLE-2008-060]
New concept for fault location in series- compensated parallel lines is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/69/files/
Detailed record - Similar records |