1.
A multi-criteria differential transformer relay based on fuzzy logic / Wiszniewski, A ; Kasztenny, B [ENY-ARTICLE-2008-197]
This paper presents a digital relay scheme for the primary protection of power transformers. [...]
http://zet10.ipee.pwr.wroc.pl/record/251/files/
Detailed record - Similar records
2.
Fuzzy Set Approach to Transformer Differential Relay / Wiszniewski, A ; Kasztenny, B [ISBN: 0-85296-559-1] [ENY-ARTICLE-2008-210]
In the process of decision making by a transformer differential relay often occurs a measure of uncertainty. [...]
http://zet10.ipee.pwr.wroc.pl/record/264/files/
Detailed record - Similar records
3.
Fuzzy Logic Application to Out-Of-Step Protection of Generators / Rebizant, W ; Feser, K [I08/2001/I-110] [ENY-ARTICLE-2008-163]
Efficient protection scheme against out-of-step (OS) conditions based on fuzzy logic (FL) technique is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/210/files/
Detailed record - Similar records
4.
Real-Time Modelling and Digital Implementation of Fuzzy-Logic Controllers / Kasztenny, B ; Hatziadoniu, C ; Wiszniewski, A [ENY-ARTICLE-2008-209]
This paper is concerned with the numerical optimization of the Fuzzy Logic Controller (FLC) for both its efficient simulation and easy real-time implementation. [...]
http://zet10.ipee.pwr.wroc.pl/record/263/files/
Detailed record - Similar records
5.
Prediction of CT saturation period for differential relay adaptation purposes / Rebizant, W ; Hayder, T ; Schiel, L [ENY-ARTICLE-2008-147]
A new approach to CT saturation assessment is presented in the paper. [...]
http://zet10.ipee.pwr.wroc.pl/record/186/files/
Detailed record - Similar records
6.
Power Swing Phenomena and its Detection and Prevention / Khan, U N ; Lu, Y [ENY-ARTICLE-2008-140]
Power Swing which is basically caused by the large disturbances in the power system which if not blocked could cause wrong operation of the distance relay and can generate wrong or undesired tripping of the transmission line circuit breaker. [...]
http://zet10.ipee.pwr.wroc.pl/record/178/files/
Detailed record - Similar records
7.
Robust Control of an Electrical Drive using Adaptive Fuzzy Logic Control Structure with Sliding-Mode Compensator / Szabat, K ; Kaminski, M ; Orlowska-Kowalska, T [1-4244-0813-X/07/$20.00 2007 IEEE.] [ENY-ARTICLE-2008-023]
In the paper a robust control system with the fuzzy adaptive controller and the additional compensator is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/30/files/
Detailed record - Similar records
8.
New Criteria of Voltage Stability Margin for the Purpose of Load Shedding / Wiszniewski, A [ENY-ARTICLE-2008-201]
Voltage instability is a phenomenon which often contributes to the development of power system disturbances. [...]
http://zet10.ipee.pwr.wroc.pl/record/255/files/
Detailed record - Similar records
9.
Analysis of influence of power quality disturbances using a neuro-fuzzy systems / Janik, P ; Leonowicz, Z ; Lobos, T ; Waclawek, Z [RZ I07/2007/I-025] [ENY-ARTICLE-2008-172]
The authors propose an automated neuro-fuzzy system approach (with neural network subsystem) to power quality assessment incorporating equipment susceptibility patterns. [...]
http://zet10.ipee.pwr.wroc.pl/record/221/files/
Detailed record - Similar records
10.
A New Fault Location Algorithm for Use with Current Differential Protective Relays of Two-Terminal Line / Izykowski, J ; Rosolowski, E ; Saha, M [ENY-ARTICLE-2008-156]
A new fault location algorithm utilising synchronised measurements of two-end currents and one-end voltage is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/203/files/
Detailed record - Similar records