Electrical Engineering Wroclaw University of Technology

Electrical Engineering Wroclaw University of Technology 10 records found  Search took 0.01 seconds. 
1.
Influence of pollution layer thickness on flashover voltage of HV insulators / Wankowicz, J ; Chrzan, K L ; Pohl, Z [ENY-ARTICLE-2012-325]
The pollution characteristics (the relationships of flashover voltage and SDD or maximum current Imax ) for insulators contaminated with uniform or nonuniform coatings with different thickness h are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/412/files/
Detailed record - Similar records
2.
Influence of High Voltage Insulator on Pollution Flashover Voltage / Wankowicz, J G ; Pohl, Z [ENY-ARTICLE-2009-233]
Results of pollution flashover voltage measurements and optical observation obtained for high voltage insulators placed in the vertical and the horizontal positions are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/292/files/
Detailed record - Similar records
3.
Impulse flashover of strings containing standard and semi-conducting disc insulators / Chrzan, K L ; Elsaesser, O [ENY-ARTICLE-2012-324]
Insulators with semi-conducting glazes (SCG insulators) are used mainly in heavily polluted areas. [...]
http://zet10.ipee.pwr.wroc.pl/record/411/files/
Detailed record - Similar records
4.
Effect of impulse polarity on the flashover voltage of polluted cap and pin insulators / Chrzan, K L ; Schwarz, H ; Haeusler, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-278]
The lightning impulse flashover voltage on clean and polluted cap and pin insulators under high humidity conditions were measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/346/files/
Detailed record - Similar records
5.
Hygroscopic Properties of Pollutants on HV Insulators / Chrzan, K L ; Pohl, Z ; Kowalak, T [I07/1988/P-337] [ENY-ARTICLE-2008-212]
The mechanism of moisture absorption by an insulator surface contaminated with different salts was described. [...]
http://zet10.ipee.pwr.wroc.pl/record/266/files/
Detailed record - Similar records
6.
PSPICE appliction for modelling of cap and pin insulator strings / Chrzan, K L ; Rebizant, W [ENY-ARTICLE-2012-318]
The use of PSPICE program in HV engineering is shown. [...]
http://zet10.ipee.pwr.wroc.pl/record/405/files/
Detailed record - Similar records
7.
Influence of profile on the pollution performance of ceramic long-rod insulators / Chrzan, K L [ENY-ARTICLE-2013-349]
The long rod insulators with different profiles were shown. [...]
http://zet10.ipee.pwr.wroc.pl/record/436/files/
Detailed record - Similar records
8.
Leakage currents on naturally contaminated porcelain and silicone insulators. / Chrzan, K L [ENY-ARTICLE-2012-308]
The leakage current measurements on standard post insulators and on rod insulators without sheds were carried out. [...]
http://zet10.ipee.pwr.wroc.pl/record/395/files/
Detailed record - Similar records
9.
Artificial rain test of outdoor long rod insulators / Chrzan, K L ; Streubel, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-279]
Due to the decrease of industrial contamination emission nearly the whole territory of Poland belongs to the pollution class light. [...]
http://zet10.ipee.pwr.wroc.pl/record/347/files/
Detailed record - Similar records
10.
Probes for spot measurement of surface conductivity on polluted insulators / Chrzan, K L ; Stec, C ; Farzaneh, M [doi:10.1049/iet-smt:20060044] [ENY-ARTICLE-2008-218]
The surface conductivity of insulators in the field is often non-uniformly distributed. [...]
http://zet10.ipee.pwr.wroc.pl/record/272/files/
Detailed record - Similar records

Haven't found what you were looking for? Try your search on other servers:
recid:412 in Google Books
recid:412 in Google Scholar
recid:412 in Google Web
recid:412 in INSPEC