1.
| Degradation of metal oxide varistors caused by electrical stresses
/ Chrzan, K L
[ENY-ARTICLE-2013-350]
The degradation of ZnO elements under AC or DC operating voltage and impulse current is described. [...]
http://zet10.ipee.pwr.wroc.pl/record/437/files/
Detailed record - Similar records |
2.
| Degradation and destruction of ZnO varistors caused by current pulses
/ Chrzan, K L ; Wroblewski, Z.
[ENY-ARTICLE-2013-345]
Although the modern metal oxide elements are resistant to degradation caused by continuous operating voltage the degradation or destruction caused by current impulses, especially lightning currents, is still a serious problem. [...]
http://zet10.ipee.pwr.wroc.pl/record/432/files/
Detailed record - Similar records |
3.
| Changes in varistors properties after radial field test
/ Jaroszewski, M ; Korycki, P ; Wieczorek, K ; Zakrzewski, J
[ENY-ARTICLE-2008-179]
ZnO varistors are used in commercial surge arresters in high voltage application in the area of power engineering. [...]
http://zet10.ipee.pwr.wroc.pl/record/229/files/
Detailed record - Similar records |
4.
| Capacitance Changes in Degraded Metal Oxide Varistors
/ Jaroszewski, M ; Wieczorek, K ; Bretuj, W ; Kostyla, P
[ENY-ARTICLE-2008-178]
ZnO based ceramics show a highly nonlinear current-voltage (I-V) characteristic due to intergranular layers at the boundaries of ZnO grains. [...]
http://zet10.ipee.pwr.wroc.pl/record/228/files/
Detailed record - Similar records |
5.
| Influence of moisture and partial discharges on the degradation of high-voltage surge arresters.
/ Chrzan, K L
[ENY-ARTICLE-2012-321]
This paper reports the influence of moisture and internal partial discharges on the degradation of metal oxide varistors in high-voltage surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/408/files/
Detailed record - Similar records |
6.
| An assessment of ageing of oxide varistors exposed to pulse hazards using dielectric spectroscopy
/ Jaroszewski, M ; Pospieszna, J
[I07/2004/I-019]
[ENY-ARTICLE-2008-115]
The common use of zinc oxide varistors has brought about qualitative changes in the overvoltage protection of electronic and electric power equipment. [...]
http://zet10.ipee.pwr.wroc.pl/record/144/files/
Detailed record - Similar records |
7.
| Influence of Partial Discharges on ZnO Varistors
/ Jaroszewski, M
[ENY-ARTICLE-2008-181]
The varistors used in HV overvoltage limiters are constantly exposed to operating voltage and environmental hazards and also to transient hazards associated with, among others, overvoltages or pollution. [...]
http://zet10.ipee.pwr.wroc.pl/record/231/files/
Detailed record - Similar records |
8.
| Internal partial discharges test for metal oxide surge arresters
/ Chrzan, K L
[ENY-ARTICLE-2012-327]
Proposals for testing of surge arresters performance under internal partial discharge stress by Sakshaug, Chrzan and Korycki have been presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/414/files/
Detailed record - Similar records |
9.
| Termovision diagnostics of metal oxide surge arresters
/ Chrzan, K L
[I07/2007/I-043]
[ENY-ARTICLE-2008-187]
The surge arresters diagnostics based on infrared temperature measurement was evaluated. [...]
http://zet10.ipee.pwr.wroc.pl/record/238/files/
Detailed record - Similar records |
10.
| Numerical calculation of varistor model for sinusoidal signal
/ Kostyla, P
[ENY-ARTICLE-2008-124]
ZnO varistors are semiconductor devices with highly nonlinear current-voltage characteristic and are widely used as devices for overvoltage protection. [...]
http://zet10.ipee.pwr.wroc.pl/record/162/files/
Detailed record - Similar records |