1.
| TSC transformer with asymmetric source and load
/ Mach, V ; Gono, R ; Leonowicz, Z
[ENY-ARTICLE-2013-351]
The paper analyses unconventional connection of a three-phase transformer with asymmetric source and load. [...]
http://zet10.ipee.pwr.wroc.pl/record/439/files/
Detailed record - Similar records |
2.
| Probabilistic Analysis of Voltage Deviations in the Distribution Network with Small Synchronous Generators
/ Sobierajski, M ; Rojewski, W
[ENY-ARTICLE-2009-245]
Fulfilling voltage quality requirements may produce the bottleneck of sending the whole local generation to the medium voltage network. [...]
http://zet10.ipee.pwr.wroc.pl/record/306/files/
Detailed record - Similar records |
3.
| New Criteria of Voltage Stability Margin for the Purpose of Load Shedding
/ Wiszniewski, A
[ENY-ARTICLE-2008-201]
Voltage instability is a phenomenon which often contributes to the development of power system disturbances. [...]
http://zet10.ipee.pwr.wroc.pl/record/255/files/
Detailed record - Similar records |
4.
| Accurate Location of Faults on Three-Terminal Line with Use of Three-End Unsynchronised Measurements
/ Izykowski, J ; Rosolowski, E ; Molag, R ; Balcerek, P ; et al
[ENY-ARTICLE-2008-157]
This paper presents a new fault location algorithm for three-terminal line utilising unsynchronised measurements of three-end currents and voltages. [...]
http://zet10.ipee.pwr.wroc.pl/record/204/files/
Detailed record - Similar records |
5.
| Statistics of Short-Circuit Signals for Power System Protection Purposes
/ Rebizant, W ; Szafran, J ; Feser, K ; Oechsle, F
[I08/2000/I-134]
[ENY-ARTICLE-2008-153]
Basic ideas of probability and statistics with application to chosen power system protection problems are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/195/files/
Detailed record - Similar records |
6.
| Reliability and Renewable Sources
/ Gono, R
[ENY-TEACHING-2010-036]
Reliability in electrical power system Renewable Sources. [...]
http://zet10.ipee.pwr.wroc.pl/record/368/files/
Detailed record - Similar records |
7.
| Inclined plane test, influence of transformer power
/ Chrzan, K L
[ISBN 978-0-620-44584-9]
[ENY-ARTICLE-2009-281]
The inclined plane method is one of a few other tests that prove the material resistance to erosion and tracking caused by surface discharges. [...]
http://zet10.ipee.pwr.wroc.pl/record/349/files/
Detailed record - Similar records |
8.
| CT saturation correction based on the estimated CT saturation time constant
/ Rebizant, W ; Wiszniewski, A ; Schiel, L
[I08/2008/I-021]
[ENY-ARTICLE-2008-203]
A new method for CT saturation correction is presented that is based on an on-line estimation of the CT magnetizing inductance. [...]
http://zet10.ipee.pwr.wroc.pl/record/257/files/
Detailed record - Similar records |
9.
| Current Transformer Saturation Detection with Genetically Optimized Neural Networks
/ Rebizant, W ; Bejmert, D
[ENY-ARTICLE-2008-146]
Application of the genetic algorithm (GA) for optimization of artificial neural network (ANN) based CT saturation detector is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/185/files/
Detailed record - Similar records |
10.
| Analysis of three-phase chopper circuits controlled by asymmetrical firing of thyristors
/ Lobos, T ; Wordoffa, A
[I08/1987/I-411]
[ENY-ARTICLE-2008-109]
Using thyristor and thyristor-diode ac choppers causes distortion of currents and voltages in electrical power networks. [...]
http://zet10.ipee.pwr.wroc.pl/record/138/files/
Detailed record - Similar records |