Electrical Engineering Wroclaw University of Technology

Electrical Engineering Wroclaw University of Technology 14 records found  1 - 10next  jump to record: Search took 0.00 seconds. 
1.
The effect of a metallic particle near a spacer on flashover phenomena in SF6. / Mazurek, B ; Cross, J D ; Heeswijk van, R G [I07/1992/P-451] [ENY-ARTICLE-2008-072]
This paper presents a study of the flashover mechanism initiated by metallic particles in SF6 gas. [...]
http://zet10.ipee.pwr.wroc.pl/record/81/files/
Detailed record - Similar records
2.
Effect of area on surface flashover voltage in vacuum / Cross, J D ; Mazurek, B [ISSN: 0018-9367INSPEC:3152462DOI: 10.1109/14.2330] [ENY-ARTICLE-2008-041]
It is known that the breakdown voltage in a vacuum insulation system drops with an increase in linear dimension of electrodes and with an increase in the number of insulating spacers bridging the gap. [...]
http://zet10.ipee.pwr.wroc.pl/record/49/files/
Detailed record - Similar records
3.
The Effect of Low Temperature on the Role Played by Electrodes in Vacuum Breakdown / Mazurek, B [I07/1988/P-343] [ENY-ARTICLE-2008-070]
Electrical breakdown requires the creation of plasma in inter electrode space. [...]
http://zet10.ipee.pwr.wroc.pl/record/79/files/
Detailed record - Similar records
4.
The Effect of the Number of Spacer Insulators on the Breakdown Voltage of Vacuum Insulation / Juchniewicz, J ; Mazurek, B ; Tyman, A [ENY-ARTICLE-2008-226]
It was shown that when extended high voltage vacuum insulation is being considered, the effect of the he number of spacer insulators on the breakdown voltage of the system has to be taken into account. [...]
http://zet10.ipee.pwr.wroc.pl/record/281/files/
Detailed record - Similar records
5.
AC Flashover Voltage in Vacuum for Different Electrode Diameters and Different Pressures / Tyman, A [ENY-ARTICLE-2008-223]
Application of vacuum insulation in cryo-installations, for example cryocables, requires investigations made on specimens and laboratory arrangements which would be very close to those met in practice. [...]
http://zet10.ipee.pwr.wroc.pl/record/278/files/
Detailed record - Similar records
6.
Fast cathode processes in conditioning of vacuum electrodes / Cross, J D ; Mazurek, B [ENY-ARTICLE-2008-069]
High - speed streak photographs of vacuum breakdown show oscillations in light emission at the cathode . [...]
http://zet10.ipee.pwr.wroc.pl/record/78/files/
Detailed record - Similar records
7.
Atmospheric Pressure Cold Plasma Reactor with Back Discharges and Parallel Gas Flow / Kacprzyk, R ; Miśta, W ; Czapka, T [ENY-ARTICLE-2011-302]
none.
http://zet10.ipee.pwr.wroc.pl/record/387/files/
Detailed record - Similar records
8.
Inactivation of Yersinia enterocolitica Gram-negative bacteria using high voltage technique / Lubicki, P ; Cross, J D ; Jayaram, S ; Mazurek, B ; et al [I07/1995/I-220] [ENY-ARTICLE-2008-077]
High voltage pulses of peak voltages U=5-75 kV and rise times tp=500-1300 ns were applied with repetition frequency f=lHz in order to cause the irreversible electroporation of Gram negative bacteria Yersinia enterocolitica. [...]
http://zet10.ipee.pwr.wroc.pl/record/95/files/
Detailed record - Similar records
9.
Studies of Epoxy Spacers Subjected to Internal and External Partial Discharge and SF6 Byproducts / Braun, J M ; Chu, F Y ; Tyman, A [ENY-ARTICLE-2008-230]
Ihe reliability of gas insulated switchgear (GIS) has generally been good. [...]
http://zet10.ipee.pwr.wroc.pl/record/285/files/
Detailed record - Similar records
10.
Franklin rods - sharp or blunt ? / Chrzan, K L [ENY-ARTICLE-2013-348]
This paper gives the historical background of 250 year old question: should the Franklin rod tip be sharp or blunt ? The earlier works, the new field results from USA and own laboratory experiments are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/435/files/
Detailed record - Similar records

Haven't found what you were looking for? Try your search on other servers:
recid:81 in Google Books
recid:81 in Google Scholar
recid:81 in Google Web
recid:81 in INSPEC