Electrical Engineering Wroclaw University of Technology

Electrical Engineering Wroclaw University of Technology 28 records found  previous11 - 20next  jump to record: Search took 0.01 seconds. 
11.
Pollution Performance of 110 kV Metal Oxide Arresters / Chrzan, K L ; Pohl, Z ; Grzybowski, S ; Kohler, W [ENY-ARTICLE-2008-216]
Pollution test results of single unit 110 kV metal oxide surge arresters with porcelain housing according to the solid layer and salt fog methods are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/270/files/
Detailed record - Similar records
12.
Behaviour of zinc oxide surge arresters under pollution / Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L [I07/1990/I-114] [ENY-ARTICLE-2008-213]
This paper presents results of pollution tests with AC voltages which were carried out with a multi-unit zinc oxide arrester. [...]
http://zet10.ipee.pwr.wroc.pl/record/267/files/
Detailed record - Similar records
13.
Temperature monitoring of metal oxide surge arresters / Chrzan, K L ; Hinrichsen, V. [ENY-ARTICLE-2013-343]
Varistor overtemperature above the ambient is an important state parameter of metal oxide surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/430/files/
Detailed record - Similar records
14.
Pollution flashover of single unit metal oxide arresters / Chrzan, K L ; Koehler, W. [ENY-ARTICLE-2013-342]
Flashover voltage of uniform and non-uniform polluted metal oxide arresters and their porcelain housings without internal parts was measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/429/files/
Detailed record - Similar records
15.
Electrical Strength of Air Containing Ozone and Nitric Oxides Produced by Intensive Partial Discharges / Chrzan, K L ; Andino, J M [ENY-ARTICLE-2008-217]
Internal arcing test results of gapped Sic arresters are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/271/files/
Detailed record - Similar records
16.
An assessment of ageing of oxide varistors exposed to pulse hazards using dielectric spectroscopy / Jaroszewski, M ; Pospieszna, J [I07/2004/I-019] [ENY-ARTICLE-2008-115]
The common use of zinc oxide varistors has brought about qualitative changes in the overvoltage protection of electronic and electric power equipment. [...]
http://zet10.ipee.pwr.wroc.pl/record/144/files/
Detailed record - Similar records
17.
Lightning impulse performance of polluted medium voltage insulators / Chrzan, K L [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-277]
The concentrated dry bands on many silicone rubber insulators and also on porcelain insulators were observed by means of termovision camera. [...]
http://zet10.ipee.pwr.wroc.pl/record/345/files/
Detailed record - Similar records
18.
Studies of Epoxy Spacers Subjected to Internal and External Partial Discharge and SF6 Byproducts / Braun, J M ; Chu, F Y ; Tyman, A [ENY-ARTICLE-2008-230]
Ihe reliability of gas insulated switchgear (GIS) has generally been good. [...]
http://zet10.ipee.pwr.wroc.pl/record/285/files/
Detailed record - Similar records
19.
Diagnostics of high voltage metal oxide arresters procedure errors / Chrzan, K L ; Koehler, W [I07/2000/I-059] [ENY-ARTICLE-2008-193]
A technique has been described which can determine ac resistive current directly or by obtaining the watt loss of the test specimen and dividing by the true rms (trms) value or the applied voltage. [...]
http://zet10.ipee.pwr.wroc.pl/record/247/files/
Detailed record - Similar records
20.
Influence of Partial Discharges on ZnO Varistors / Jaroszewski, M [ENY-ARTICLE-2008-181]
The varistors used in HV overvoltage limiters are constantly exposed to operating voltage and environmental hazards and also to transient hazards associated with, among others, overvoltages or pollution. [...]
http://zet10.ipee.pwr.wroc.pl/record/231/files/
Detailed record - Similar records

Haven't found what you were looking for? Try your search on other servers:
recid:408 in Google Books
recid:408 in Google Scholar
recid:408 in Google Web
recid:408 in INSPEC