Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 6 rekordów  Szukanie trwało 0.02 sekund. 
1. Correction of Current Transformer Transient Performance / Wiszniewski, A ; Rebizant, W ; Schiel, L [ENY-ARTICLE-2008-202]
If a current transformer (CT) saturates while transforming the heavy primary current, in each period, there are sections when the magnetic core is unsaturated and transformation is correct, and when it is saturated, it causes enormous errors. [...]
http://zet10.ipee.pwr.wroc.pl/record/256/files/
Rekord szczegółowy - Podobne rekordy
2. Fuzzy Logic Application to Out-Of-Step Protection of Generators / Rebizant, W ; Feser, K [I08/2001/I-110] [ENY-ARTICLE-2008-163]
Efficient protection scheme against out-of-step (OS) conditions based on fuzzy logic (FL) technique is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/210/files/
Rekord szczegółowy - Podobne rekordy
3. Efficient Frequency-Adaptive Amplitude Tracking Algorithms for Protection Purposes / Rebizant, W ; Rusek, B [I08/2003/I-091] [ENY-ARTICLE-2008-159]
The new, fast and adaptive algorithms for measurement of signal amplitude for protection and control purposes are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/206/files/
Rekord szczegółowy - Podobne rekordy
4. Current Transformer Saturation Detection with Genetically Optimized Neural Networks / Rebizant, W ; Bejmert, D [ENY-ARTICLE-2008-146]
Application of the genetic algorithm (GA) for optimization of artificial neural network (ANN) based CT saturation detector is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/185/files/
Rekord szczegółowy - Podobne rekordy
5. Wavelet Transform Approach to High Impedance Fault Detection in MV Networks / Michalik, M ; Rebizant, W ; Lukowicz, M ; Lee, S J ; et al [ENY-ARTICLE-2008-145]
Application of wavelet transform technique to high impedance arcing fault detection in distribution networks is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/184/files/
Rekord szczegółowy - Podobne rekordy
6. Real-Time Determination of Power System Frequency / Lobos, T ; Rezmer, J [ENY-ARTICLE-2008-009]
The main frequency is an important parameter of an electrical power system. [...]
http://zet10.ipee.pwr.wroc.pl/record/10/files/
Rekord szczegółowy - Podobne rekordy

Jeżeli nie znaleziono tego czego szukasz, spróbuj szukać na innych serwerach:
protective relaying w Google Books
protective relaying w Google Scholar
protective relaying w Google Web
protective relaying w INSPEC