1.
| Behaviour of Zinc Oxide Surge Arresters Under Pollution
/ Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L
[ENY-ARTICLE-2008-214]
This paper presents results of pollution tests with A. [...]
http://zet10.ipee.pwr.wroc.pl/record/268/files/
Rekord szczegółowy - Podobne rekordy |
2.
| Behaviour of zinc oxide surge arresters under pollution
/ Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L
[I07/1990/I-114]
[ENY-ARTICLE-2008-213]
This paper presents results of pollution tests with AC voltages which were carried out with a multi-unit zinc oxide arrester. [...]
http://zet10.ipee.pwr.wroc.pl/record/267/files/
Rekord szczegółowy - Podobne rekordy |
3.
| Internal Arcing Test on Polluted High Voltage Surge Arresters
/ Chrzan, K L ; Kohler, W ; Feser, K
[ENY-ARTICLE-2009-234]
A test to prove the performance of extremely non-uniform polluted single unit metal oxide (MO) and gapped arresters (SiCA) is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/293/files/
Rekord szczegółowy - Podobne rekordy |
4.
| Pollution Performance of 110 kV Metal Oxide Arresters
/ Chrzan, K L ; Pohl, Z ; Grzybowski, S ; Kohler, W
[ENY-ARTICLE-2008-216]
Pollution test results of single unit 110 kV metal oxide surge arresters with porcelain housing according to the solid layer and salt fog methods are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/270/files/
Rekord szczegółowy - Podobne rekordy |
5.
| Changes in varistors properties after radial field test
/ Jaroszewski, M ; Korycki, P ; Wieczorek, K ; Zakrzewski, J
[ENY-ARTICLE-2008-179]
ZnO varistors are used in commercial surge arresters in high voltage application in the area of power engineering. [...]
http://zet10.ipee.pwr.wroc.pl/record/229/files/
Rekord szczegółowy - Podobne rekordy |
6.
| Internal partial discharges test for metal oxide surge arresters
/ Chrzan, K L
[ENY-ARTICLE-2012-327]
Proposals for testing of surge arresters performance under internal partial discharge stress by Sakshaug, Chrzan and Korycki have been presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/414/files/
Rekord szczegółowy - Podobne rekordy |
7.
| Influence of moisture and partial discharges on the degradation of high-voltage surge arresters.
/ Chrzan, K L
[ENY-ARTICLE-2012-321]
This paper reports the influence of moisture and internal partial discharges on the degradation of metal oxide varistors in high-voltage surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/408/files/
Rekord szczegółowy - Podobne rekordy |
8.
| Termovision diagnostics of metal oxide surge arresters
/ Chrzan, K L
[I07/2007/I-043]
[ENY-ARTICLE-2008-187]
The surge arresters diagnostics based on infrared temperature measurement was evaluated. [...]
http://zet10.ipee.pwr.wroc.pl/record/238/files/
Rekord szczegółowy - Podobne rekordy |
9.
| Degradation and destruction of ZnO varistors caused by current pulses
/ Chrzan, K L ; Wroblewski, Z.
[ENY-ARTICLE-2013-345]
Although the modern metal oxide elements are resistant to degradation caused by continuous operating voltage the degradation or destruction caused by current impulses, especially lightning currents, is still a serious problem. [...]
http://zet10.ipee.pwr.wroc.pl/record/432/files/
Rekord szczegółowy - Podobne rekordy |
10.
| Behaviour of Insulators and Surge Arresters at Glogow Pollution Test Station
/ Chrzan, K L ; Haddad, A
[I07/2005/I-005]
[ENY-ARTICLE-2008-222]
The paper reports on the pollution performance of different insulators and surge arresters at Glogow test station from 1981 up to 2004. [...]
http://zet10.ipee.pwr.wroc.pl/record/277/files/
Rekord szczegółowy - Podobne rekordy |