Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 13 rekordów  1 - 10następny  skocz do rekordu: Szukanie trwało 0.01 sekund. 
1.
Electrical Strength of Air Containing Ozone and Nitric Oxides Produced by Intensive Partial Discharges / Chrzan, K L ; Andino, J M [ENY-ARTICLE-2008-217]
Internal arcing test results of gapped Sic arresters are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/271/files/
Rekord szczegółowy - Podobne rekordy
2.
Internal Arcing Test on Polluted High Voltage Surge Arresters / Chrzan, K L ; Kohler, W ; Feser, K [ENY-ARTICLE-2009-234]
A test to prove the performance of extremely non-uniform polluted single unit metal oxide (MO) and gapped arresters (SiCA) is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/293/files/
Rekord szczegółowy - Podobne rekordy
3.
Effect of Water conductivity on its Pulse Electric Strength / Lubicki, P ; Cross, J D ; Jayaram, S ; Staron, J ; et al [ENY-ARTICLE-2008-082]
The dependence of the impulse electrical strength of water on conductivity was investigated in non-uniform electric field - point-plate electrode system. [...]
http://zet10.ipee.pwr.wroc.pl/record/100/files/
Rekord szczegółowy - Podobne rekordy
4.
Effect of impulse polarity on the flashover voltage of polluted cap and pin insulators / Chrzan, K L ; Schwarz, H ; Haeusler, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-278]
The lightning impulse flashover voltage on clean and polluted cap and pin insulators under high humidity conditions were measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/346/files/
Rekord szczegółowy - Podobne rekordy
5.
Effect of arc current on properties of composite insulators for overhead lines / Mazurek, B ; Maczka, T ; Gmitrzak, A [I07/2000/I-055] [ENY-ARTICLE-2008-084]
Results of power arc tests carried out on composite insulators for 110 kV overhead lines are analyzed. [...]
http://zet10.ipee.pwr.wroc.pl/record/102/files/
Rekord szczegółowy - Podobne rekordy
6.
Influence of moisture and partial discharges on the degradation of high-voltage surge arresters. / Chrzan, K L [ENY-ARTICLE-2012-321]
This paper reports the influence of moisture and internal partial discharges on the degradation of metal oxide varistors in high-voltage surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/408/files/
Rekord szczegółowy - Podobne rekordy
7.
Internal partial discharges test for metal oxide surge arresters / Chrzan, K L [ENY-ARTICLE-2012-327]
Proposals for testing of surge arresters performance under internal partial discharge stress by Sakshaug, Chrzan and Korycki have been presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/414/files/
Rekord szczegółowy - Podobne rekordy
8.
Impulse flashover of strings containing standard and semi-conducting disc insulators / Chrzan, K L ; Elsaesser, O [ENY-ARTICLE-2012-324]
Insulators with semi-conducting glazes (SCG insulators) are used mainly in heavily polluted areas. [...]
http://zet10.ipee.pwr.wroc.pl/record/411/files/
Rekord szczegółowy - Podobne rekordy
9.
Switching Vacuum Arc in a Pulsed Transverse Magnetic Field / Klajn, A [ENY-ARTICLE-2008-195]
An experimental analysis of the vacuum arc behavior in a pulsed transverse magnetic field with amplitudes up to 120 mT and frequency of 900 Hz is presented in the paper. [...]
http://zet10.ipee.pwr.wroc.pl/record/249/files/
Rekord szczegółowy - Podobne rekordy
10.
Changes in varistors properties after radial field test / Jaroszewski, M ; Korycki, P ; Wieczorek, K ; Zakrzewski, J [ENY-ARTICLE-2008-179]
ZnO varistors are used in commercial surge arresters in high voltage application in the area of power engineering. [...]
http://zet10.ipee.pwr.wroc.pl/record/229/files/
Rekord szczegółowy - Podobne rekordy

Jeżeli nie znaleziono tego czego szukasz, spróbuj szukać na innych serwerach:
recid:271 w Google Books
recid:271 w Google Scholar
recid:271 w Google Web
recid:271 w INSPEC