1.
Computation of Voltage Sag Initiation with Fourier based Algorithm, Kalman Filter and Wavelets / Amaris, H ; Alvarez, A ; Florez, D ; Lobos, T ; et al [ENY-ARTICLE-2009-264]
Dynamic Voltage Restorers (DVR) have been successfully applied for voltage dip mitigation in the last years. [...]
http://zet10.ipee.pwr.wroc.pl/record/332/files/
Rekord szczegółowy - Podobne rekordy
2.
Wavelets and Prony Method for Disturbance Detection in Wind Farms / Lobos, T ; Rezmer, J ; Janik, P ; Amaris, H ; et al [ENY-ARTICLE-2008-155]
Wind generator impact on power quality is crucial for power system operation. [...]
http://zet10.ipee.pwr.wroc.pl/record/202/files/
Rekord szczegółowy - Podobne rekordy
3.
Wavelets an Hilbert Transform methods for detection of voltage dips and micro interruptions / Caciotta, M ; Giarnetti, S ; Leccese, F ; Leonowicz, Z ; et al [ENY-PREPRINT-2009-009]
In electrical energy power network, disturbances can cause problems in electronic devices therefore their monitoring is fundamental in Power Quality field both to properly dimension protections and to calculate compensations in case of malfunction of the apparatus. [...]
http://zet10.ipee.pwr.wroc.pl/record/315/files/
Rekord szczegółowy - Podobne rekordy
4.
Digital Methods for on-line Estimation of the Basic Components of Signals in Electrical Power Systems / Lobos, T ; Schneider, E ; Eichhorn, K F [I08/1987/I-398] [ENY-ARTICLE-2008-076]
The fast determination of the Symetrical Components of voltages and currents in three-phase systems is very important for the analysis of faults and protection tasks. [...]
http://zet10.ipee.pwr.wroc.pl/record/94/files/
Rekord szczegółowy - Podobne rekordy
5.
Detection of Short Transients and Interruptions using the Hilbert Transform / Caciotta, M ; Giarnetti, S ; Leccese, F ; Leonowicz, Z [ENY-ARTICLE-2009-269]
In electrical energy power networks, disturbances can cause problems in electronic devices so their monitoring is fundamental in Power Quality. [...]
http://zet10.ipee.pwr.wroc.pl/record/337/files/
Rekord szczegółowy - Podobne rekordy
6.
Damping of the Torsional Vibration in Two-Mass Drive System Using Forced Dynamic Control / Szabat, K ; Orlowska-Kowalska, T [1-4244-0813-X/07/$20.00 2007 IEEE] [ENY-ARTICLE-2008-027]
The paper deals with the application of forced dynamic control strategy in the two-mass resonant system. [...]
http://zet10.ipee.pwr.wroc.pl/record/34/files/
Rekord szczegółowy - Podobne rekordy
7.
New Digital Algorithms for On-line Determination of Symmetrical Components in Power Systems / Lobos, T ; Schneider, E [ENY-ARTICLE-2010-293]
Using the Fourier method the Kalman theory and the Walsh functions, non-recursive algorithms for the on-line determination of the basic waveforms of the symmetrical components in three-phase power systems are introduced, investigated and compared. [...]
http://zet10.ipee.pwr.wroc.pl/record/366/files/
Rekord szczegółowy - Podobne rekordy
8.
Wavelets and Hilbert Transform for detection of short disturbances in electrical power networks / Caciotta, M ; Giarnetti, S ; Leccese, F ; Leonowicz, Z [ENY-ARTICLE-2010-287]
In electrical energy power network, disturbances can cause problems in electronic devices therefore their monitoring is fundamental to properly design the protection and compensation devices. [...]